Literature DB >> 23076921

Cemented, cementless or hybrid fixation options in total knee arthroplasty for osteoarthritis and other non-traumatic diseases.

Gilberto Yoshinobu Nakama1, Maria Stella Peccin, Gustavo J M Almeida, Ozório de Almeida Lira Neto, Antônio A B Queiroz, Ricardo Dizioli Navarro.   

Abstract

BACKGROUND: It is not clear which fixation of total knee arthroplasty obtains the best clinical, functional and radiographic results in people with osteoarthritis and other non-traumatic diseases, such as rheumatoid arthritis.
OBJECTIVES: To assess the benefits and harms of cemented, cementless and hybrid knee prostheses fixation techniques in participants with primary osteoarthritis (osteoarthritis following trauma was not included) and other non-traumatic diseases, such as rheumatoid arthritis. SEARCH
METHODS: We searched CENTRAL (2011, issue 10), MEDLINE via PubMed, EMBASE, Current Controlled Trials, LILACS, The Cumulative Index to Nursing and Allied Health Literature, SPORTDiscus, Health Technology Assessment Database and the Database of Abstracts of Reviews of Effectiveness, all from implementation to October 2011, along with handsearches of high-yield journals and reference lists of articles. No language restrictions were applied. SELECTION CRITERIA: Randomized controlled trials (RCTs) evaluating cemented, cementless and hybrid fixation. Participants included patients that were 18 years or older with osteoarthritis and other non-traumatic diseases who were undergoing primary total knee arthroplasty. DATA COLLECTION AND ANALYSIS: Three authors independently selected the eligible trials, assessed the trial quality, risk of bias and extracted data. Researchers were contacted to obtain missing information. MAIN
RESULTS: Five RCTs and 297 participants were included in this review. Using meta-analysis on roentgen stereophotogrammetric analysis (RSA) we observed that cemented fixation of the tibial components demonstrated smaller displacement in relation to cementless fixation (with and without hydroxyapatite) after a follow-up of two years (maximum total point-motion, N = 167, two RCTs, mean difference (MD) = 0.52 mm, 95% confidence interval (CI) 0.31 to 0.74). However, the risk of future aseptic loosening with uncemented fixation was approximately half that of cemented fixation according to the arthroplasty instability classification (moderate quality as assessed by GRADE) inferred from RSA (N = 216, three RCTs, risk ratio (RR) = 0.47, 95% CI 0.24 to 0.92) with a 16% absolute risk difference between groups. The number needed to treat for an additional beneficial outcome (NNTB) to prevent future aseptic loosening was 7 (95% CI 5 to 44). There was a low risk of bias for RSA among the studies included. It was not possible to perform meta-analysis on patient-important outcomes, such as the survival rate of the implant (any change of a component), patient global assessments, functional measures, pain, health-related quality of life measures and adverse events. Almost all included studies recorded functional measures of Knee Society and Hospital for Special Surgery knee scores, but the authors of each study found no significant difference between the groups. AUTHORS'
CONCLUSIONS: There was a smaller displacement of the cemented tibial component in relation to the cementless fixation in studies with osteoarthritis and rheumatoid arthritis participants who underwent primary total knee prosthesis with a follow-up of two years; however, the cemented fixation presented a greater risk of future aseptic loosening than cementless fixation.

Entities:  

Mesh:

Substances:

Year:  2012        PMID: 23076921     DOI: 10.1002/14651858.CD006193.pub2

Source DB:  PubMed          Journal:  Cochrane Database Syst Rev        ISSN: 1361-6137


  34 in total

1.  Roentgen stereophotogrammetric analysis: an effective tool to predict implant survival after an all-poly unicompartmental knee arthroplasty-a 10 year follow-up study.

Authors:  Danilo Bruni; Laura Bragonzoni; Michele Gagliardi; Marco Bontempi; Ibrahim Akkawi; Giovanni Francesco Raspugli; Francesco Iacono; Silvio Patella; Maurilio Marcacci
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2014-06-11       Impact factor: 4.342

2.  Controversies in total knee arthroplasty: Cochrane evidence or surgeons' philosophy?

Authors:  Patrick Sadoghi
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2015-07-02       Impact factor: 4.342

3.  Predictive factors for failure after total knee replacement revision.

Authors:  Rafael Luque; Belen Rizo; Antonio Urda; Rodrigo Garcia-Crespo; Enrique Moro; Fernando Marco; Luis López-Duran
Journal:  Int Orthop       Date:  2014-01-09       Impact factor: 3.075

4.  CORR Insights®: the Mark Coventry Award: Trabecular metal tibial components were durable and reliable in primary total knee arthroplasty: a randomized clinical trial.

Authors:  William L Bargar
Journal:  Clin Orthop Relat Res       Date:  2014-04-30       Impact factor: 4.176

Review 5.  Cementless fixation in medial unicompartmental knee arthroplasty: a systematic review.

Authors:  S Campi; H G Pandit; C A F Dodd; D W Murray
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2016-07-19       Impact factor: 4.342

Review 6.  Cementless total knee arthroplasty.

Authors:  Alessandro Aprato; Salvatore Risitano; Luigi Sabatini; Matteo Giachino; Gabriele Agati; Alessandro Massè
Journal:  Ann Transl Med       Date:  2016-04

7.  Better clinical outcomes and overall higher survival with hybrid versus cemented primary total knee arthroplasty: a minimum 15 years follow-up.

Authors:  Alejandro Lizaur-Utrilla; Fancisco A Miralles-Muñoz; Matias Ruiz-Lozano; Santiago González-Parreño; Carolina Alonso-Montero; Fernando A Lopez-Prats
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2020-04-28       Impact factor: 4.342

8.  Trabecular metal in total knee arthroplasty associated with higher knee scores: a randomized controlled trial.

Authors:  Mariano Fernandez-Fairen; Daniel Hernández-Vaquero; Antonio Murcia; Ana Torres; Rafael Llopis
Journal:  Clin Orthop Relat Res       Date:  2013-07-25       Impact factor: 4.176

9.  Intermittent Parathyroid Hormone Enhances Cancellous Osseointegration of a Novel Murine Tibial Implant.

Authors:  Xu Yang; Benjamin F Ricciardi; Aleksey Dvorzhinskiy; Caroline Brial; Zachary Lane; Samrath Bhimani; Jayme C Burket; Bin Hu; Alexander M Sarkisian; F Patrick Ross; Marjolein C H van der Meulen; Mathias P G Bostrom
Journal:  J Bone Joint Surg Am       Date:  2015-07-01       Impact factor: 5.284

10.  Primary modular total knee replacement in severe and unstable osteoarthritis. Predictive factors for failure.

Authors:  Rafael Luque; Belen Rizo; Antonio Urda; Rodrigo Garcia-Crespo; Enrique Moro; Luis López-Durán
Journal:  Int Orthop       Date:  2015-07-01       Impact factor: 3.075

View more