Literature DB >> 23076044

On removing interpolation and resampling artifacts in rigid image registration.

Iman Aganj1, Boon Thye Thomas Yeo, Mert R Sabuncu, Bruce Fischl.   

Abstract

We show that image registration using conventional interpolation and summation approximations of continuous integrals can generally fail because of resampling artifacts. These artifacts negatively affect the accuracy of registration by producing local optima, altering the gradient, shifting the global optimum, and making rigid registration asymmetric. In this paper, after an extensive literature review, we demonstrate the causes of the artifacts by comparing inclusion and avoidance of resampling analytically. We show the sum-of-squared-differences cost function formulated as an integral to be more accurate compared with its traditional sum form in a simple case of image registration. We then discuss aliasing that occurs in rotation, which is due to the fact that an image represented in the Cartesian grid is sampled with different rates in different directions, and propose the use of oscillatory isotropic interpolation kernels, which allow better recovery of true global optima by overcoming this type of aliasing. Through our experiments on brain, fingerprint, and white noise images, we illustrate the superior performance of the integral registration cost function in both the Cartesian and spherical coordinates, and also validate the introduced radial interpolation kernel by demonstrating the improvement in registration.

Entities:  

Mesh:

Year:  2012        PMID: 23076044      PMCID: PMC3694571          DOI: 10.1109/TIP.2012.2224356

Source DB:  PubMed          Journal:  IEEE Trans Image Process        ISSN: 1057-7149            Impact factor:   10.856


  27 in total

1.  Post-registration spatial filtering to reduce noise in functional MRI data sets.

Authors:  L C Maas; P F Renshaw
Journal:  Magn Reson Imaging       Date:  1999-11       Impact factor: 2.546

2.  Survey: interpolation methods in medical image processing.

Authors:  T M Lehmann; C Gönner; K Spitzer
Journal:  IEEE Trans Med Imaging       Date:  1999-11       Impact factor: 10.048

3.  Interpolation artefacts in non-rigid registration.

Authors:  P Aljabar; J V Hajnal; R G Boyes; D Rueckert
Journal:  Med Image Comput Comput Assist Interv       Date:  2005

4.  Avoidance of additional aliasing in multipass image rotations.

Authors:  D Fraser; R A Schowengerdt
Journal:  IEEE Trans Image Process       Date:  1994       Impact factor: 10.856

5.  Comparison of interpolating methods for image resampling.

Authors:  J Parker; R V Kenyon; D E Troxel
Journal:  IEEE Trans Med Imaging       Date:  1983       Impact factor: 10.048

6.  A fast, robust pattern recognition asystem for low light level image registration and its application to retinal imaging.

Authors:  A Wade; F Fitzke
Journal:  Opt Express       Date:  1998-08-31       Impact factor: 3.894

7.  Estimating the joint statistics of images using nonparametric windows with application to registration using mutual information.

Authors:  Nicholas Dowson; Timor Kadir; Richard Bowden
Journal:  IEEE Trans Pattern Anal Mach Intell       Date:  2008-10       Impact factor: 6.226

8.  Interpolation artifacts in sub-pixel image registration.

Authors:  Gustavo K Rohde; Akram Aldroubi; Dennis M Healy
Journal:  IEEE Trans Image Process       Date:  2008-12-22       Impact factor: 10.856

9.  Multi-modal volume registration by maximization of mutual information.

Authors:  W M Wells; P Viola; H Atsumi; S Nakajima; R Kikinis
Journal:  Med Image Anal       Date:  1996-03       Impact factor: 8.545

10.  Steerable pyramids and tight wavelet frames in L2(R(d)).

Authors:  Michael Unser; Nicolas Chenouard; Dimitri Van de Ville
Journal:  IEEE Trans Image Process       Date:  2011-04-07       Impact factor: 10.856

View more
  11 in total

1.  SYMMETRIC NON-RIGID IMAGE REGISTRATION VIA AN ADAPTIVE QUASI-VOLUME-PRESERVING CONSTRAINT.

Authors:  Iman Aganj; Martin Reuter; Mert R Sabuncu; Bruce Fischl
Journal:  Proc IEEE Int Symp Biomed Imaging       Date:  2013-04

2.  Mid-space-independent deformable image registration.

Authors:  Iman Aganj; Juan Eugenio Iglesias; Martin Reuter; Mert Rory Sabuncu; Bruce Fischl
Journal:  Neuroimage       Date:  2017-02-24       Impact factor: 6.556

3.  Multimodal Image Registration through Simultaneous Segmentation.

Authors:  Iman Aganj; Bruce Fischl
Journal:  IEEE Signal Process Lett       Date:  2017-09-19       Impact factor: 3.109

4.  Avoiding symmetry-breaking spatial non-uniformity in deformable image registration via a quasi-volume-preserving constraint.

Authors:  Iman Aganj; Martin Reuter; Mert R Sabuncu; Bruce Fischl
Journal:  Neuroimage       Date:  2014-10-30       Impact factor: 6.556

5.  Effects of Resolution and Registration Algorithm on the Accuracy of EPI vNavs for Real Time Head Motion Correction in MRI.

Authors:  Yingzhuo Zhang; Iman Aganj; André J W van der Kouwe; M Dylan Tisdall
Journal:  Conf Comput Vis Pattern Recognit Workshops       Date:  2016-12-19

6.  Machine Learning Based on a Multiparametric and Multiregional Radiomics Signature Predicts Radiotherapeutic Response in Patients with Glioblastoma.

Authors:  Zi-Qi Pan; Shu-Jun Zhang; Xiang-Lian Wang; Yu-Xin Jiao; Jian-Jian Qiu
Journal:  Behav Neurol       Date:  2020-10-24       Impact factor: 3.342

7.  Mid-Space-Independent Symmetric Data Term for Pairwise Deformable Image Registration.

Authors:  Iman Aganj; Juan Eugenio Iglesias; Martin Reuter; Mert Rory Sabuncu; Bruce Fischl
Journal:  Med Image Comput Comput Assist Interv       Date:  2015-11-20

8.  Dynamic cardiac PET motion correction using 3D normalized gradient fields in patients and phantom simulations.

Authors:  Jonathon A Nye; Marina Piccinelli; Doyeon Hwang; Charles David Cooke; Jin Chul Paeng; Joo Myung Lee; Sang-Geon Cho; Russell Folks; Hee-Seung Bom; Bon-Kwon Koo; Ernest V Garcia
Journal:  Med Phys       Date:  2021-07-20       Impact factor: 4.506

Review 9.  Recent Trends, Technical Concepts and Components of Computer-Assisted Orthopedic Surgery Systems: A Comprehensive Review.

Authors:  Jan Kubicek; Filip Tomanec; Martin Cerny; Dominik Vilimek; Martina Kalova; David Oczka
Journal:  Sensors (Basel)       Date:  2019-11-27       Impact factor: 3.576

10.  Impact of image preprocessing methods on reproducibility of radiomic features in multimodal magnetic resonance imaging in glioblastoma.

Authors:  Hajar Moradmand; Seyed Mahmoud Reza Aghamiri; Reza Ghaderi
Journal:  J Appl Clin Med Phys       Date:  2019-12-27       Impact factor: 2.102

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.