Literature DB >> 23053982

Development of an enhanced chemiluminescence immunoassay (CLIA) for detecting urinary albumin.

Elham Sadat Aghaei Meibodi1, Maedeh Darziani Azizi, Malieh Paknejad, Bagher Larijani, Kobra Omidfar.   

Abstract

In the present study, a sensitive and competitive chemiluminescence immunoassay (CLIA) was developed in order to detect human serum albumin (HSA) in urine specimen. The method utilizes a home-made monoclonal anti-albumin antibody conjugated to horseradish peroxidase enzyme (mAb-HRP). Sensitivity, specificity and linearity of the assay were evaluated. According to the results, the proper concentration of HSA and mAb-HRP conjugates was 800 ng/100 μl and 1:200 respectively. In optimal conditions, this method could detect HSA in a high linear range of 10-200 μg ml(-1) with the low detection limit of 0.025 μg ml(-1). No evidence of interference with presence of probable substances in the urine samples indicated its high specificity and selectivity. Moreover, high reproducibility as well as high sensitivity and specificity of the test were confirmed using diabetic and non-diabetic samples. Significant concordance was observed between CLIA and immunoturbidimetry assay regarding detection of HSA. The results of the present study can be considered in accordance with the current demands such as reliability, accuracy, convenience and high speed of performance for a precise protein detection method. Furthermore, it may be regarded as a more rapid, simpler and cheaper alternative compared to other sophisticated assays.

Entities:  

Mesh:

Substances:

Year:  2012        PMID: 23053982     DOI: 10.1007/s11033-012-1981-5

Source DB:  PubMed          Journal:  Mol Biol Rep        ISSN: 0301-4851            Impact factor:   2.316


  24 in total

1.  Stabilization of penicillinase-hapten conjugate for enzyme immunoassay.

Authors:  K Omidfar; Mohammad J Rasaee; Ali B Zaraee; M Pour Amir; F Rahbarizadeh
Journal:  J Immunoassay Immunochem       Date:  2002

2.  Development of urinary albumin immunosensor based on colloidal AuNP and PVA.

Authors:  Kobra Omidfar; Ahmad Dehdast; Hajar Zarei; Behnoush Khorsand Sourkohi; Bagher Larijani
Journal:  Biosens Bioelectron       Date:  2011-04-16       Impact factor: 10.618

3.  A rapid and sensitive method for estimating low concentrations of albumin in human urine.

Authors:  J K Horton; M Davies; J S Woodhead; I Weeks
Journal:  Clin Chim Acta       Date:  1989-12-29       Impact factor: 3.786

4.  Albuminuria and risk of cardiovascular events, death, and heart failure in diabetic and nondiabetic individuals.

Authors:  H C Gerstein; J F Mann; Q Yi; B Zinman; S F Dinneen; B Hoogwerf; J P Hallé; J Young; A Rashkow; C Joyce; S Nawaz; S Yusuf
Journal:  JAMA       Date:  2001-07-25       Impact factor: 56.272

5.  Microalbuminuria is common, also in a nondiabetic, nonhypertensive population, and an independent indicator of cardiovascular risk factors and cardiovascular morbidity.

Authors:  H L Hillege; W M Janssen; A A Bak; G F Diercks; D E Grobbee; H J Crijns; W H Van Gilst; D De Zeeuw; P E De Jong
Journal:  J Intern Med       Date:  2001-06       Impact factor: 8.989

6.  Chemiluminescent immunoassay (CLIA) for urinary albumin.

Authors:  F J Bagazgoitia; J L Garcia; J M Ibarra; R Patiño; C Diéquez; I Weeks; J S Woodhead
Journal:  J Biolumin Chemilumin       Date:  1989 Oct-Dec

7.  Development and validation of a particle-enhanced turbidimetric inhibition assay for urine albumin on the Dade aca analyzer.

Authors:  H Thakkar; D J Newman; P Holownia; C L Davey; C C Wang; J Lloyd; A R Craig; C P Price
Journal:  Clin Chem       Date:  1997-01       Impact factor: 8.327

8.  A new competitive enzyme linked immunosorbent assay (MRP83-CA15-3) for MUC1 measurement in breast cancer.

Authors:  J Mohammadnejad; Mohammad J Rasaee; B Saqhafi; M Rajabibazl; F Rahbarizadeh; K Omidfar; M Paknejad
Journal:  J Immunoassay Immunochem       Date:  2006

9.  Production and characterization of monoclonal antibody against human serum albumin.

Authors:  K Omidfar; S Kashanian; M Paknejad; S Kashanian; B Larijani; H Roshanfekr
Journal:  Hybridoma (Larchmt)       Date:  2007-08

10.  Screening and management of microalbuminuria in patients with diabetes mellitus: recommendations to the Scientific Advisory Board of the National Kidney Foundation from an ad hoc committee of the Council on Diabetes Mellitus of the National Kidney Foundation.

Authors:  P H Bennett; S Haffner; B L Kasiske; W F Keane; C E Mogensen; H H Parving; M W Steffes; G E Striker
Journal:  Am J Kidney Dis       Date:  1995-01       Impact factor: 8.860

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.