Development and validation of a particle-enhanced turbidimetric inhibition assay for urine albumin on the Dade aca analyzer.

H Thakkar1, D J Newman, P Holownia, C L Davey, C C Wang, J Lloyd, A R Craig, C P Price.   

Abstract

The measurement of urine albumin now has a well-established role in the monitoring of patients with diabetes mellitus. We have developed a particle-enhanced immunoturbidimetric inhibition assay for urine albumin on the Dade aca analyzer. The inhibition approach removes any of the potential antigen excess difficulties that could be expected from the wide clinical range of urine albumin, but retains the sensitivity advantages of latex-enhanced immunoturbidimetry. Human serum albumin (HSA) is covalently attached to 40-nm poly(chloromethyl)styrene-modified latex particles. This reagent, along with monoclonal antibody to HSA, is aliquoted into the aca reagent pack along with polyethylene glycol 8000 in a tablet form (giving a final reaction concentration of 15 g/L). A 150 mmol/L phosphate buffer, pH 7.8, is used to fill the reagent pack in the instrument and the agglutination reaction is monitored at 340 nm. The sample volume is 100 microL and the calibration curve covers the range 2-250 mg/L. Evaluation of commercial scale reagents against the Beckman Array nephelometric immunoassay system gave a Deming regression correlation of aca = 0.87 x Beckman + 8.5, r = 0.995, n = 145. Mean analytical recovery was 104+/-4.5%, n = 20, and there was no evidence of a lack of parallelism. Interassay precision was 8.8% at 10.0 mg/L and <2.5% at >65 mg/L. Calibrator stability was in excess of 60 days. A small reference range study (24-h urine collections, n = 27) gave a mean of 5.6 mg/L with a range of 0.5-16.2 mg/L. Analytical sensitivity (2.5 SD from zero) was 0.40 mg/L.

Entities:  

Mesh:

Substances:

Year:  1997        PMID: 8990231

Source DB:  PubMed          Journal:  Clin Chem        ISSN: 0009-9147            Impact factor:   8.327


  7 in total

1.  Selective Detection of Human Serum Albumin by Near Infrared Emissive Fluorophores: Insights into Structure-property Relationship.

Authors:  Rajib Choudhury; Siddhi Rajeshbhai Patel; Anindya Ghosh
Journal:  J Photochem Photobiol A Chem       Date:  2019-02-28       Impact factor: 4.291

Review 2.  Validation and quality control of protein microarray-based analytical methods.

Authors:  Larry J Kricka; Stephen R Master
Journal:  Mol Biotechnol       Date:  2007-08-03       Impact factor: 2.695

3.  Development of an enhanced chemiluminescence immunoassay (CLIA) for detecting urinary albumin.

Authors:  Elham Sadat Aghaei Meibodi; Maedeh Darziani Azizi; Malieh Paknejad; Bagher Larijani; Kobra Omidfar
Journal:  Mol Biol Rep       Date:  2012-10-07       Impact factor: 2.316

4.  Dual luminescent charge transfer probe for quantitative detection of serum albumin in aqueous samples.

Authors:  Rajib Choudhury; Benjamin Quattlebaum; Charles Conkin; Siddhi Rajeshbhai Patel; Kallie Mendenhall
Journal:  Spectrochim Acta A Mol Biomol Spectrosc       Date:  2020-03-24       Impact factor: 4.098

5.  An immunonanogold resonance scattering-quenching probe for rapid and sensitive assay of microalbumin.

Authors:  Zhi-Liang Jiang; Yu-Juan Huang; Ai-Hui Liang
Journal:  J Fluoresc       Date:  2008-01-06       Impact factor: 2.217

6.  On-chip immunoassay for determination of urinary albumin.

Authors:  Wanida Laiwattanapaisal; Temsiri Songjaroen; Thitima Maturos; Tanom Lomas; Assawapong Sappat; Adisorn Tuantranont
Journal:  Sensors (Basel)       Date:  2009-12-10       Impact factor: 3.576

7.  Albuminuria and Reduced Estimated Glomerular Filtration Rate among First-degree Relatives of Patients with Chronic Kidney Disease in Lagos, Southwest Nigeria.

Authors:  Y R Raji; M O Mabayoje; B T Bello; C O Amira
Journal:  Indian J Nephrol       Date:  2018 Jan-Feb
  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.