Literature DB >> 23047492

High-throughput screening of large volumes of whole blood using structured illumination and fluorescent on-chip imaging.

Serap Altay Arpali1, Caglar Arpali, Ahmet F Coskun, Hsin-Hao Chiang, Aydogan Ozcan.   

Abstract

Undiluted blood samples are difficult to image in large volumes since blood constitutes a highly absorbing and scattering medium. As a result of this limitation, optical imaging of rare cells (e.g., circulating tumour cells) within unprocessed whole blood remains a challenge, demanding the use of special microfluidic technologies. Here we demonstrate a new fluorescent on-chip imaging modality that can rapidly screen large volumes of absorbing and scattering media, such as undiluted whole blood samples, for detection of fluorescent micro-objects at low concentrations (for example ≤50-100 particles/mL). In this high-throughput imaging modality, a large area microfluidic device (e.g., 7-18 cm(2)), which contains for example ~0.3-0.7 mL of undiluted whole blood sample, is directly positioned onto a wide-field opto-electronic sensor-array such that the fluorescent emission within the microchannel can be detected without the use of any imaging lenses. This microfluidic device is then illuminated and laterally scanned with an array of Gaussian excitation spots, which is generated through a spatial light modulator. For each scanning position of this excitation array, a lensfree fluorescent image of the blood sample is captured using the opto-electronic sensor-array, resulting in a sequence of images (e.g., 144 lensfree frames captured in ~36 s) for the same sample chip. Digitally merging these lensfree fluorescent images based on a maximum intensity projection (MIP) algorithm enabled us to significantly boost the signal-to-noise ratio (SNR) and contrast of the fluorescent micro-objects within whole blood, which normally remain undetected (i.e., hidden) using conventional uniform excitation schemes, involving plane wave illumination. This high-throughput on-chip imaging platform based on structured excitation could be useful for rare cell research by enabling rapid screening of large volume microfluidic devices that process whole blood and other optically dense media.

Entities:  

Mesh:

Substances:

Year:  2012        PMID: 23047492      PMCID: PMC3485428          DOI: 10.1039/c2lc40894e

Source DB:  PubMed          Journal:  Lab Chip        ISSN: 1473-0189            Impact factor:   6.799


  18 in total

1.  11-color, 13-parameter flow cytometry: identification of human naive T cells by phenotype, function, and T-cell receptor diversity.

Authors:  S C De Rosa; L A Herzenberg; L A Herzenberg; M Roederer
Journal:  Nat Med       Date:  2001-02       Impact factor: 53.440

Review 2.  Raising the speed limits for 4D fluorescence microscopy.

Authors:  A T Hammond; B S Glick
Journal:  Traffic       Date:  2000-12       Impact factor: 6.215

3.  Beyond six colors: a new era in flow cytometry.

Authors:  Stephen C De Rosa; Jason M Brenchley; Mario Roederer
Journal:  Nat Med       Date:  2003-01       Impact factor: 53.440

Review 4.  Seventeen-colour flow cytometry: unravelling the immune system.

Authors:  Stephen P Perfetto; Pratip K Chattopadhyay; Mario Roederer
Journal:  Nat Rev Immunol       Date:  2004-08       Impact factor: 53.106

Review 5.  A guide to choosing fluorescent proteins.

Authors:  Nathan C Shaner; Paul A Steinbach; Roger Y Tsien
Journal:  Nat Methods       Date:  2005-12       Impact factor: 28.547

Review 6.  Volume rendering versus maximum intensity projection in CT angiography: what works best, when, and why.

Authors:  Elliot K Fishman; Derek R Ney; David G Heath; Frank M Corl; Karen M Horton; Pamela T Johnson
Journal:  Radiographics       Date:  2006 May-Jun       Impact factor: 5.333

7.  Automated analysis of the mitotic phases of human cells in 3D fluorescence microscopy image sequences.

Authors:  Nathalie Harder; Felipe Mora-Bermúdez; William J Godinez; Jan Ellenberg; Roland Eils; Karl Rohr
Journal:  Med Image Comput Comput Assist Interv       Date:  2006

Review 8.  Quantum dots versus organic dyes as fluorescent labels.

Authors:  Ute Resch-Genger; Markus Grabolle; Sara Cavaliere-Jaricot; Roland Nitschke; Thomas Nann
Journal:  Nat Methods       Date:  2008-09       Impact factor: 28.547

9.  High-throughput lensfree imaging and characterization of a heterogeneous cell solution on a chip.

Authors:  Ting-Wei Su; Sungkyu Seo; Anthony Erlinger; Aydogan Ozcan
Journal:  Biotechnol Bioeng       Date:  2009-02-15       Impact factor: 4.530

10.  Isolation of rare circulating tumour cells in cancer patients by microchip technology.

Authors:  Sunitha Nagrath; Lecia V Sequist; Shyamala Maheswaran; Daphne W Bell; Daniel Irimia; Lindsey Ulkus; Matthew R Smith; Eunice L Kwak; Subba Digumarthy; Alona Muzikansky; Paula Ryan; Ulysses J Balis; Ronald G Tompkins; Daniel A Haber; Mehmet Toner
Journal:  Nature       Date:  2007-12-20       Impact factor: 49.962

View more
  15 in total

1.  Biophysical investigation of living monocytes in flow by collaborative coherent imaging techniques.

Authors:  David Dannhauser; Domenico Rossi; Pasquale Memmolo; Andrea Finizio; Pietro Ferraro; Paolo Antonio Netti; Filippo Causa
Journal:  Biomed Opt Express       Date:  2018-10-04       Impact factor: 3.732

2.  Wide and scalable field-of-view Talbot-grid-based fluorescence microscopy.

Authors:  Shuo Pang; Chao Han; Mihoko Kato; Paul W Sternberg; Changhuei Yang
Journal:  Opt Lett       Date:  2012-12-01       Impact factor: 3.776

3.  Multilayer fluorescence imaging on a single-pixel detector.

Authors:  Kaikai Guo; Shaowei Jiang; Guoan Zheng
Journal:  Biomed Opt Express       Date:  2016-06-01       Impact factor: 3.732

4.  Wide field-of-view on-chip Talbot fluorescence microscopy for longitudinal cell culture monitoring from within the incubator.

Authors:  Chao Han; Shuo Pang; Danielle V Bower; Patrick Yiu; Changhuei Yang
Journal:  Anal Chem       Date:  2013-02-06       Impact factor: 6.986

5.  Giga-pixel fluorescent imaging over an ultra-large field-of-view using a flatbed scanner.

Authors:  Zoltán Göröcs; Yuye Ling; Meng Dai Yu; Dimitri Karahalios; Kian Mogharabi; Kenny Lu; Qingshan Wei; Aydogan Ozcan
Journal:  Lab Chip       Date:  2013-11-21       Impact factor: 6.799

6.  Spectral demultiplexing in holographic and fluorescent on-chip microscopy.

Authors:  Ikbal Sencan; Ahmet F Coskun; Uzair Sikora; Aydogan Ozcan
Journal:  Sci Rep       Date:  2014-01-20       Impact factor: 4.379

7.  Dictionary-enhanced imaging cytometry.

Authors:  Antony Orth; Diane Schaak; Ethan Schonbrun
Journal:  Sci Rep       Date:  2017-02-22       Impact factor: 4.379

Review 8.  Microfluidic-Based Multi-Organ Platforms for Drug Discovery.

Authors:  Ahmad Rezaei Kolahchi; Nima Khadem Mohtaram; Hassan Pezeshgi Modarres; Mohammad Hossein Mohammadi; Armin Geraili; Parya Jafari; Mohsen Akbari; Amir Sanati-Nezhad
Journal:  Micromachines (Basel)       Date:  2016-09-08       Impact factor: 2.891

9.  Malaria Diagnosis Using a Mobile Phone Polarized Microscope.

Authors:  Casey W Pirnstill; Gerard L Coté
Journal:  Sci Rep       Date:  2015-08-25       Impact factor: 4.379

Review 10.  Various on-chip sensors with microfluidics for biological applications.

Authors:  Hun Lee; Linfeng Xu; Domin Koh; Nikhila Nyayapathi; Kwang W Oh
Journal:  Sensors (Basel)       Date:  2014-09-12       Impact factor: 3.576

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.