Literature DB >> 23040220

Dosimetric impact of using the Acuros XB algorithm for intensity modulated radiation therapy and RapidArc planning in nasopharyngeal carcinomas.

Monica W K Kan1, Lucullus H T Leung, Peter K N Yu.   

Abstract

PURPOSE: To assess the dosimetric implications for the intensity modulated radiation therapy (IMRT) and volumetric modulated arc therapy with RapidArc (RA) of nasopharyngeal carcinomas (NPC) due to the use of the Acuros XB (AXB) algorithm versus the anisotropic analytical algorithm (AAA). METHODS AND MATERIALS: Nine-field sliding window IMRT and triple-arc RA plans produced for 12 patients with NPC using AAA were recalculated using AXB. The dose distributions to multiple planning target volumes (PTVs) with different prescribed doses and critical organs were compared. The PTVs were separated into components in bone, air, and tissue. The change of doses by AXB due to air and bone, and the variation of the amount of dose changes with number of fields was also studied using simple geometric phantoms.
RESULTS: Using AXB instead of AAA, the averaged mean dose to PTV70 (70 Gy was prescribed to PTV70) was found to be 0.9% and 1.2% lower for IMRT and RA, respectively. It was approximately 1% lower in tissue, 2% lower in bone, and 1% higher in air. The averaged minimum dose to PTV70 in bone was approximately 4% lower for both IMRT and RA, whereas it was approximately 1.5% lower for PTV70 in tissue. The decrease in target doses estimated by AXB was mostly contributed from the presence of bone, less from tissue, and none from air. A similar trend was observed for PTV60 (60 Gy was prescribed to PTV60). The doses to most serial organs were found to be 1% to 3% lower and to other organs 4% to 10% lower for both techniques.
CONCLUSIONS: The use of the AXB algorithm is highly recommended for IMRT and RapidArc planning for NPC cases.
Copyright © 2013 Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Year:  2012        PMID: 23040220     DOI: 10.1016/j.ijrobp.2012.08.031

Source DB:  PubMed          Journal:  Int J Radiat Oncol Biol Phys        ISSN: 0360-3016            Impact factor:   7.038


  24 in total

1.  Optimizing the flattening filter free beam selection in RapidArc®-based stereotactic body radiotherapy for Stage I lung cancer.

Authors:  J-Y Lu; Z Lin; P-X Lin; B-T Huang
Journal:  Br J Radiol       Date:  2015-07-02       Impact factor: 3.039

2.  Accuracy of dose calculation algorithms for virtual heterogeneous phantoms and intensity-modulated radiation therapy in the head and neck.

Authors:  Ryota Onizuka; Fujio Araki; Takeshi Ohno; Yuji Nakaguchi; Yudai Kai; Yuuki Tomiyama; Kazunari Hioki
Journal:  Radiol Phys Technol       Date:  2016-01

3.  Impact of acuros XB algorithm in deep-inspiration breath-hold (DIBH) respiratory techniques used for the treatment of left breast cancer.

Authors:  Lalit Kumar; Vimal Kishore; Manindra Bhushan; Abhinav Dewan; Girigesh Yadav; Kothanda Raman; Gourav Kumar; Irfan Ahmad; Kundan S Chufal; Munish Gairola
Journal:  Rep Pract Oncol Radiother       Date:  2020-04-27

4.  Dose accuracy improvement on head and neck VMAT treatments by using the Acuros algorithm and accurate FFF beam calibration.

Authors:  Guadalupe Martin-Martin; Stefan Walter; Eduardo Guibelalde
Journal:  Rep Pract Oncol Radiother       Date:  2021-02-25

5.  Dosimetric effects of the acuros XB and anisotropic analytical algorithm on volumetric modulated arc therapy planning for prostate cancer using an endorectal balloon.

Authors:  Taeryool Koo; Jin-Beom Chung; Keun-Yong Eom; Jin-Yong Seok; In-Ah Kim; Jae-Sung Kim
Journal:  Radiat Oncol       Date:  2015-02-22       Impact factor: 3.481

6.  Heterogeneity correction for intensity-modulated frameless SRS in pituitary and cavernous sinus tumors: a retrospective study.

Authors:  Lisa B E Shields; Cindy Bond; Aaron Odom; David A Sun; Aaron C Spalding
Journal:  Radiat Oncol       Date:  2015-09-17       Impact factor: 3.481

7.  A comparative analysis of Acuros XB and the analytical anisotropic algorithm for volumetric modulation arc therapy.

Authors:  Raju P Srivastava; K Basta; Werner De Gersem; Carlos De Wagter
Journal:  Rep Pract Oncol Radiother       Date:  2021-06-09

8.  A review on the use of grid-based Boltzmann equation solvers for dose calculation in external photon beam treatment planning.

Authors:  Monica W K Kan; Peter K N Yu; Lucullus H T Leung
Journal:  Biomed Res Int       Date:  2013-08-27       Impact factor: 3.411

9.  Critical appraisal of the accuracy of Acuros-XB and Anisotropic Analytical Algorithm compared to measurement and calculations with the compass system in the delivery of RapidArc clinical plans.

Authors:  Murugesan Kathirvel; Shanmuga Subramanian; Alessandro Clivio; Gandhi Arun; Antonella Fogliata; Giorgia Nicolini; Vellaiyan Subramani; Shanmugam Thirumalai Swamy; Eugenio Vanetti; Luca Cozzi
Journal:  Radiat Oncol       Date:  2013-06-11       Impact factor: 3.481

10.  Correlation between the γ passing rates of IMRT plans and the volumes of air cavities and bony structures in head and neck cancer.

Authors:  Zhengwen Shen; Xia Tan; Shi Li; Xiumei Tian; Huanli Luo; Ying Wang; Fu Jin
Journal:  Radiat Oncol       Date:  2021-07-21       Impact factor: 3.481

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.