Literature DB >> 23023395

High efficiency multishot interleaved spiral-in/out: acquisition for high-resolution BOLD fMRI.

Youngkyoo Jung1, Alexey A Samsonov, Thomas T Liu, Giedrius T Buracas.   

Abstract

Growing demand for high spatial resolution blood oxygenation level dependent (BOLD) functional magnetic resonance imaging faces a challenge of the spatial resolution versus coverage or temporal resolution tradeoff, which can be addressed by methods that afford increased acquisition efficiency. Spiral acquisition trajectories have been shown to be superior to currently prevalent echo-planar imaging in terms of acquisition efficiency, and high spatial resolution can be achieved by employing multiple-shot spiral acquisition. The interleaved spiral in/out trajectory is preferred over spiral-in due to increased BOLD signal contrast-to-noise ratio (CNR) and higher acquisition efficiency than that of spiral-out or noninterleaved spiral in/out trajectories (Law & Glover. Magn Reson Med 2009; 62:829-834.), but to date applicability of the multishot interleaved spiral in/out for high spatial resolution imaging has not been studied. Herein we propose multishot interleaved spiral in/out acquisition and investigate its applicability for high spatial resolution BOLD functional magnetic resonance imaging. Images reconstructed from interleaved spiral-in and -out trajectories possess artifacts caused by differences in T2 decay, off-resonance, and k-space errors associated with the two trajectories. We analyze the associated errors and demonstrate that application of conjugate phase reconstruction and spectral filtering can substantially mitigate these image artifacts. After applying these processing steps, the multishot interleaved spiral in/out pulse sequence yields high BOLD CNR images at in-plane resolution below 1 × 1 mm while preserving acceptable temporal resolution (4 s) and brain coverage (15 slices of 2 mm thickness). Moreover, this method yields sufficient BOLD CNR at 1.5 mm isotropic resolution for detection of activation in hippocampus associated with cognitive tasks (Stern memory task). The multishot interleaved spiral in/out acquisition is a promising technique for high spatial resolution BOLD functional magnetic resonance imaging applications.
© 2012 Wiley Periodicals, Inc.

Entities:  

Keywords:  BOLD; functional MRI; high resolution; spiral imaging

Mesh:

Year:  2012        PMID: 23023395      PMCID: PMC3535559          DOI: 10.1002/mrm.24476

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  27 in total

1.  Unaliasing by fourier-encoding the overlaps using the temporal dimension (UNFOLD), applied to cardiac imaging and fMRI.

Authors:  B Madore; G H Glover; N J Pelc
Journal:  Magn Reson Med       Date:  1999-11       Impact factor: 4.668

2.  Effect of windowing and zero-filled reconstruction of MRI data on spatial resolution and acquisition strategy.

Authors:  M A Bernstein; S B Fain; S J Riederer
Journal:  J Magn Reson Imaging       Date:  2001-09       Impact factor: 4.813

3.  Fast, iterative image reconstruction for MRI in the presence of field inhomogeneities.

Authors:  Bradley P Sutton; Douglas C Noll; Jeffrey A Fessler
Journal:  IEEE Trans Med Imaging       Date:  2003-02       Impact factor: 10.048

4.  Comparison of physiological noise at 1.5 T, 3 T and 7 T and optimization of fMRI acquisition parameters.

Authors:  C Triantafyllou; R D Hoge; G Krueger; C J Wiggins; A Potthast; G C Wiggins; L L Wald
Journal:  Neuroimage       Date:  2005-05-15       Impact factor: 6.556

5.  Laminar profiles of functional activity in the human brain.

Authors:  David Ress; Gary H Glover; Junjie Liu; Brian Wandell
Journal:  Neuroimage       Date:  2006-09-29       Impact factor: 6.556

6.  Selection of a convolution function for Fourier inversion using gridding [computerised tomography application].

Authors:  J I Jackson; C H Meyer; D G Nishimura; A Macovski
Journal:  IEEE Trans Med Imaging       Date:  1991       Impact factor: 10.048

7.  Self-navigated spiral fMRI: interleaved versus single-shot.

Authors:  G H Glover; S Lai
Journal:  Magn Reson Med       Date:  1998-03       Impact factor: 4.668

8.  Multiband multislice GE-EPI at 7 tesla, with 16-fold acceleration using partial parallel imaging with application to high spatial and temporal whole-brain fMRI.

Authors:  Steen Moeller; Essa Yacoub; Cheryl A Olman; Edward Auerbach; John Strupp; Noam Harel; Kâmil Uğurbil
Journal:  Magn Reson Med       Date:  2010-05       Impact factor: 4.668

9.  Human ocular dominance columns as revealed by high-field functional magnetic resonance imaging.

Authors:  K Cheng; R A Waggoner; K Tanaka
Journal:  Neuron       Date:  2001-10-25       Impact factor: 17.173

10.  Application of k-space energy spectrum analysis for inherent and dynamic B0 mapping and deblurring in spiral imaging.

Authors:  Trong-Kha Truong; Nan-Kuei Chen; Allen W Song
Journal:  Magn Reson Med       Date:  2010-10       Impact factor: 4.668

View more
  2 in total

1.  A simple acquisition strategy to avoid off-resonance blurring in spiral imaging with redundant spiral-in/out k-space trajectories.

Authors:  Samuel W Fielden; Craig H Meyer
Journal:  Magn Reson Med       Date:  2014-03-06       Impact factor: 4.668

2.  A spiral-based volumetric acquisition for MR temperature imaging.

Authors:  Samuel W Fielden; Xue Feng; Li Zhao; G Wilson Miller; Matthew Geeslin; Robert F Dallapiazza; W Jeffrey Elias; Max Wintermark; Kim Butts Pauly; Craig H Meyer
Journal:  Magn Reson Med       Date:  2017-11-08       Impact factor: 4.668

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.