Literature DB >> 23020394

A low noise single-transistor transimpedance preamplifier for Fourier-transform mass spectrometry using a T feedback network.

Tzu-Yung Lin1, Roger J Green, Peter B O'Connor.   

Abstract

A novel single-transistor transimpedance preamplifier has been introduced for improving performance in Fourier-transform ion cyclotron resonance (FT-ICR) mass spectrometry. A low noise junction field-effect transistor (JFET), BF862, is used as the main amplification stage of this trans-impedance preamplifier, and a T-shaped feedback network is introduced as both the feedback and the gate biasing solutions. The T feedback network has been studied using an operational amplifier (Op Amp), AD8099. Such a feedback system allows ~100-fold less feedback resistance at a given transimpedance, hence preserving bandwidth, which is beneficial to applications demanding high gain. The single-transistor preamplifier yields a tested transimpedance of ~10(4) Ω (80 dBΩ) in the frequency range between 1 kHz and 1 MHz (mass-to-charge ratio, m/z, of around 180-180k for a 12-T FT-ICR system), with a low power consumption of ~6 mW, which implies that this preamplifier is well suited to a 12-T FT-ICR mass spectrometer. In trading noise performance for higher trans-impedance, an alternative preamplifier design, an AD8099 preamplifier with the T feedback network, has also been studied with a capability of ~10(6) Ω (120 dBΩ) transimpedance in the same frequency range. The resistive components in the T feedback network reported here can be replaced by complex impedances, which allows adaptation of this feedback system to other frequency, transimpedance, and noise characteristics for applications not only in other mass spectrometers, such as Orbitrap, time-of-flight (TOF), and ion trap systems, but also in other charge/current detecting systems such as spectroscopy systems, microscopy systems, optical communication systems, or charge-coupled devices (CCDs).

Entities:  

Mesh:

Year:  2012        PMID: 23020394      PMCID: PMC3470605          DOI: 10.1063/1.4751851

Source DB:  PubMed          Journal:  Rev Sci Instrum        ISSN: 0034-6748            Impact factor:   1.523


  11 in total

1.  Electrostatic axially harmonic orbital trapping: a high-performance technique of mass analysis

Authors: 
Journal:  Anal Chem       Date:  2000-03-15       Impact factor: 6.986

2.  Preliminary fingerprinting of Athabasca oil sands polar organics in environmental samples using electrospray ionization Fourier transform ion cyclotron resonance mass spectrometry.

Authors:  J V Headley; M P Barrow; K M Peru; B Fahlman; R A Frank; G Bickerton; M E McMaster; J Parrott; L M Hewitt
Journal:  Rapid Commun Mass Spectrom       Date:  2011-07-15       Impact factor: 2.419

3.  Use of statistical methods for estimation of total number of charges in a mass spectrometry experiment.

Authors:  Parminder Kaur; Peter B O'Connor
Journal:  Anal Chem       Date:  2004-05-15       Impact factor: 6.986

4.  A gain and bandwidth enhanced transimpedance preamplifier for Fourier-transform ion cyclotron resonance mass spectrometry.

Authors:  Tzu-Yung Lin; Roger J Green; Peter B O'Connor
Journal:  Rev Sci Instrum       Date:  2011-12       Impact factor: 1.523

5.  Cryogenic ultra-low-noise SiGe transistor amplifier.

Authors:  B I Ivanov; M Trgala; M Grajcar; E Il'ichev; H-G Meyer
Journal:  Rev Sci Instrum       Date:  2011-10       Impact factor: 1.523

6.  C60 secondary ion Fourier transform ion cyclotron resonance mass spectrometry.

Authors:  Donald F Smith; Errol W Robinson; Aleksey V Tolmachev; Ron M A Heeren; Ljiljana Paša-Tolić
Journal:  Anal Chem       Date:  2011-11-18       Impact factor: 6.986

7.  A novel 9.4 tesla FTICR mass spectrometer with improved sensitivity, mass resolution, and mass range.

Authors:  Nathan K Kaiser; John P Quinn; Gregory T Blakney; Christopher L Hendrickson; Alan G Marshall
Journal:  J Am Soc Mass Spectrom       Date:  2011-05-05       Impact factor: 3.109

8.  A low-noise, wideband preamplifier for a Fourier-transform ion cyclotron resonance mass spectrometer.

Authors:  Raman Mathur; Ronald W Knepper; Peter B O'Connor
Journal:  J Am Soc Mass Spectrom       Date:  2007-09-29       Impact factor: 3.109

9.  Petroleomics: advanced molecular probe for petroleum heavy ends.

Authors:  Chang S Hsu; Christopher L Hendrickson; Ryan P Rodgers; Amy M McKenna; Alan G Marshall
Journal:  J Mass Spectrom       Date:  2011-04       Impact factor: 1.982

10.  Use of top-down and bottom-up Fourier transform ion cyclotron resonance mass spectrometry for mapping calmodulin sites modified by platinum anticancer drugs.

Authors:  Huilin Li; Tzu-Yung Lin; Steve L Van Orden; Yao Zhao; Mark P Barrow; Ana M Pizarro; Yulin Qi; Peter J Sadler; Peter B O'Connor
Journal:  Anal Chem       Date:  2011-11-18       Impact factor: 6.986

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.