Challenges in device closure of a large patent ductus arteriosus in infants weighing less than 6 kg.

I B Vijayalakshmi1, Narasimhan Chitra, Jayan Praveen, Simha Rao Prasanna.   

Abstract

INTRODUCTION: Transcatheter closure of patent ductus arteriosus (PDA) has replaced surgery in most institutions. Despite improvements in techniques and the devices available, closure of large PDA in very small infants remains a challenge. AIM: To assess the challenges, feasibility, and efficacy of device closure of large PDA, in infants weighing ≤6 kg.
MATERIALS AND METHODS: Analysis of device closure of a PDA was done in 61 infants ≤6 kg. Their ages, ranged from 9 days-12 months (mean 8.9 months), weight ranged from 2.2 to 6 kg (mean 5.3 kg), and PDA measured 3.2-8.7 mm (mean 4.8 mm). The fluoroscopy time was 3-18 minutes. The largest device used was 12 × 10 mm.
RESULTS: Successful device placement was achieved in 60/61 infants (98.4%). Mild aortic obstruction occurred in 2 cases (3.3%), as the device got displaced towards the aorta after release. The device embolized in 2 cases (3.3%). In one it was retrieved by a novel method like fastening the screw in the aorta and was closed with a 4 × 6 ADO II. In the other infant, with a single kidney, died of uremia after device retrieval. Mild left pulmonary artery (LPA) obstruction occurred in one case (1.6%). Four cases (6.6%) had minor vascular complications. The postprocedure weight gain after 3 months was between 2.5 kg ± 250 mg.
CONCLUSIONS: Device closure of large PDA in infants weighing ≤6 kg with left ventricular failure is challenging but possible, safe and effective. Retrieval of embolized device could be tricky.
© 2012, Wiley Periodicals, Inc.

Entities:  

Mesh:

Year:  2012        PMID: 23017089     DOI: 10.1111/j.1540-8183.2012.00762.x

Source DB:  PubMed          Journal:  J Interv Cardiol        ISSN: 0896-4327            Impact factor:   2.279


  3 in total

1.  Transthoracic echocardiography as an alternative major guidance to angiography during transcatheter closure of patent ductus arteriosus: technical feasibility and clinical relevance.

Authors:  Wanhua Chen; Xiaoping Yan; Yu Huang; Xudong Sun; Ling Zhong; Jinguo Li; Hua Chen; Huiying Zhong; Lianglong Chen
Journal:  Pediatr Cardiol       Date:  2014-07-29       Impact factor: 1.655

2.  The new Occlutech® PDA occluder: Initial human experience.

Authors:  M A Elbashier Abdelbasit; Mazeni Alwi; Geetha Kandavello; Marhisham Che Mood; Hasri Samion; Ziyad M Hijazi
Journal:  Catheter Cardiovasc Interv       Date:  2015-04-02       Impact factor: 2.692

3.  Echocardiography-guided percutaneous closure of perimembranous ventricular septal defects without arterial access and fluoroscopy.

Authors:  Haisong Bu; Yifeng Yang; Qin Wu; Wancun Jin; Tianli Zhao
Journal:  BMC Pediatr       Date:  2019-08-31       Impact factor: 2.125

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.