Transthoracic echocardiography as an alternative major guidance to angiography during transcatheter closure of patent ductus arteriosus: technical feasibility and clinical relevance.

Wanhua Chen1, Xiaoping Yan, Yu Huang, Xudong Sun, Ling Zhong, Jinguo Li, Hua Chen, Huiying Zhong, Lianglong Chen.   

Abstract

The conventional transcatheter closure of patent ductus arteriosus (PDA) requires femoral artery puncture and angiography for duct anatomic and shunting estimation. If such estimation can be replaced by transthoracic echocardiography (TTE), the procedure will be further simplified, with fewer invasions. This study aimed to examine whether TTE can serve as an alternative to aorta angiography and as a major guidance for transcatheter duct closure. The study enrolled 298 consecutive patients (71 males and 227 females) with PDA. In the study, TTE with combined two-dimensional echocardiography (2DE) imaging and color-coded flow imaging (CDFI) was performed to measure the minimal shunting width (MSW) as the estimated minimal duct size for selection of an Amplatzer duct occluder (ADO) and to monitor the transcatheter duct closure intraprocedurally. The MSW was validated against the duct-stretched diameter (SDD), against the minimal waist diameter of the conical part of a released occluder measured by X-ray spot picture after successful duct closure (SDC), and against the size of the finally used ADO (SADO). Good correlation was found between MSW and SDD [SDD (mm) = 1.31 MSW; r = 0.89; p < 0.01] and between MSW and SADO [SADO (mm) = 1.71 MSW; r = 0.88; p < 0.01]. Of 296 patients who received occlusion using MSW as the reference for selection of the occluder, SDC was attained in 288 (97.3%), 5 (1.7%), and 2 (0.7%) patients, respectively, at the first, second (1 ADO replacement), and third (2 ADO replacements) occluding attempt. Acute occluder dislodgement occurred in one patient (0.3%). At the 12-month follow-up assessment, no major complications were found, and the total immediate or 12-month SDC was 99.7%. Echocardiography as an alternative major guidance to angiography for transcatheter duct closure is technically feasible, and TTE guidance can further simplify the procedure, with fewer invasions and potential complications.

Entities:  

Mesh:

Year:  2014        PMID: 25070385     DOI: 10.1007/s00246-014-0956-9

Source DB:  PubMed          Journal:  Pediatr Cardiol        ISSN: 0172-0643            Impact factor:   1.655


  22 in total

1.  Closure of the patent ductus arteriosus with the amplatzer PDA device: immediate results of the international clinical trial.

Authors:  H J Faella; Z M Hijazi
Journal:  Catheter Cardiovasc Interv       Date:  2000-09       Impact factor: 2.692

2.  Late adverse reactions to intravascular iodine based contrast media: an update.

Authors:  Marie-France Bellin; Fulvio Stacul; Judith A W Webb; Henrik S Thomsen; Sameh K Morcos; Torsten Almén; Peter Aspelin; Olivier Clement; Gertraud Heinz-Peer; Peter Reimer; Aart van der Molen
Journal:  Eur Radiol       Date:  2011-07-16       Impact factor: 5.315

3.  Further experience with transcatheter closure of the patent ductus arteriosus using the Amplatzer duct occluder.

Authors:  B D Thanopoulos; F A Hakim; A Hiari; Y Goussous; E Basta; A A Zarayelyan; G S Tsaousis
Journal:  J Am Coll Cardiol       Date:  2000-03-15       Impact factor: 24.094

4.  Transcatheter closure of persistent ductus arteriosus in infants using the Amplatzer duct occluder.

Authors:  G Fischer; J Stieh; A Uebing; R Grabitz; H H Kramer
Journal:  Heart       Date:  2001-10       Impact factor: 5.994

5.  Long-term outcome of transcatheter patent ductus arteriosus closure using Amplatzer duct occluders.

Authors:  Jozef Masura; Peter Tittel; Pavol Gavora; Tomaz Podnar
Journal:  Am Heart J       Date:  2006-03       Impact factor: 4.749

6.  Challenges in device closure of a large patent ductus arteriosus in infants weighing less than 6 kg.

Authors:  I B Vijayalakshmi; Narasimhan Chitra; Jayan Praveen; Simha Rao Prasanna
Journal:  J Interv Cardiol       Date:  2012-09-27       Impact factor: 2.279

7.  Percutaneous closure of a moderate to large tubular or elongated patent ductus arteriosus in children younger than 3 years: is the ADO II appropriate?

Authors:  Saktheeswaran Mahesh Kumar; Venkateshwaran Subramanian; Sasidharan Bijulal; Kavassery Mahadevan Krishnamoorthy; Sivasubramonian Sivasankaran; Jaganmohan A Tharakan
Journal:  Pediatr Cardiol       Date:  2013-04-17       Impact factor: 1.655

8.  Percutaneous closure of medium and large PDAs using amplatzer duct occluder (ADO) I and II in infants: safety and efficacy.

Authors:  Rasha I Ammar; Ranya A Hegazy
Journal:  J Invasive Cardiol       Date:  2012-11       Impact factor: 2.022

9.  Transcatheter closure of persistent ductus arteriosus with the Amplatzer duct occluder in very young symptomatic children.

Authors:  G Butera; G De Rosa; M Chessa; L Piazza; A Delogu; A Frigiola; M Carminati
Journal:  Heart       Date:  2004-12       Impact factor: 5.994

Review 10.  The ALARA concept in pediatric cardiac catheterization: techniques and tactics for managing radiation dose.

Authors:  Henri Justino
Journal:  Pediatr Radiol       Date:  2006-09
View more
  6 in total

1.  Echocardiographic Versus Angiographic Assessment of Patent Arterial Duct in Percutaneous Closure: Towards X-ray Free Duct Occlusion?

Authors:  Inês Carmo Mendes; Hannah Heard; Kelly Peacock; Thomas Krasemann; Gareth J Morgan
Journal:  Pediatr Cardiol       Date:  2017-01-11       Impact factor: 1.655

2.  Transcatheter perimembranous ventricular septal defect closure under transthoracic echocardiographic guidance without fluoroscopy.

Authors:  Shouzheng Wang; Wenbin Ouyang; Yao Liu; Fengwen Zhang; Gaili Guo; Guangzhi Zhao; Xiangbin Pan
Journal:  J Thorac Dis       Date:  2018-09       Impact factor: 2.895

3.  Percutaneous device closure of pediatirc patent ductus arteriosus through femoral artery guidance by transthoracic echocardiography without radiation and contrast agents.

Authors:  Zankai Ye; Zhiqiang Li; Hanlu Yi; Yaobin Zhu; Yan Sun; Pei Li; Ning Ma
Journal:  J Cardiothorac Surg       Date:  2020-05-24       Impact factor: 1.637

4.  Clinical study of stand-alone transthoracic echocardiography-guided percutaneous occlusion of patent ductus arteriosus.

Authors:  Hua Cao; Qiang Chen; Gui Can Zhang; Liang Wan Chen; Fan Xu; Jia-Xin Zhang
Journal:  Anatol J Cardiol       Date:  2018-07       Impact factor: 1.596

5.  Accuracy of Routine 2D Echocardiography to Estimate Patent Ductus Arteriosus Type and Dimension and Predict Device Selection for Successful PDA Occlusion.

Authors:  Mohammed Omar Galal; Zaheer Ahmad; Arif Hussain; Masroor Sharfi; Yahia El Mahdi; Fayzah El Khattab; Amjad Alkouatli; Riad Abou Zahr
Journal:  J Saudi Heart Assoc       Date:  2021-11-29

6.  Transcatheter Closure of Patent Ductus Arteriosus under Echocardiography Guidance: A Randomized Controlled Noninferiority Trial.

Authors:  Cheng Wang; Fengwen Zhang; Wenbin Ouyang; Guangzhi Zhao; Wenxin Lu; Mengxuan Zou; Xiangbin Pan
Journal:  J Interv Cardiol       Date:  2020-10-03       Impact factor: 2.279

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.