Literature DB >> 23011907

Contrast-enhanced specific absorption rate-efficient 3D cardiac cine with respiratory-triggered radiofrequency gating.

Markus Henningsson1, Raymond H Chan, Beth Goddu, Lois A Goepfert, Reza Razavi, Rene M Botnar, Tobias Schaeffter, Reza Nezafat.   

Abstract

PURPOSE: To investigate the use of radiofrequency (RF) gating in conjunction with a paramagnetic contrast agent to reduce the specific absorption rate (SAR) and increase the blood-myocardium contrast in balanced steady-state free precession (bSSFP) 3D cardiac cine.
MATERIALS AND METHODS: RF gating was implemented by synchronizing the RF-excitation with an external respiratory sensor (bellows), which could additionally be used for respiratory gating. For reference, respiratory-gated 3D cine images were acquired without RF gating. Free-breathing 3D cine images were acquired in eight healthy subjects before and after contrast injection (Gd-BOPTA) and compared to breath-hold 2D cine.
RESULTS: RF-gated 3D cine reduced the SAR by nearly 40% without introducing significant artifacts while providing left ventricle (LV) measurements similar to those obtained with 2D cine. The contrast-to-noise ratio (CNR) was significantly higher for 3D cine compared to 2D cine, both before and after contrast injection; however, no statistically significant CNR increase was observed for the postcontrast 3D cine compared to the precontrast acquisitions.
CONCLUSION: Respiratory-triggered RF gating significantly reduces SAR in 3D cine acquisitions, which may enable a more widespread clinical use of 3D cine. Furthermore, CNR of 3D bSSFP cine is higher than of 2D and administration of Gd-BOPTA does not improve the CNR of 3D cine.
Copyright © 2012 Wiley Periodicals, Inc.

Entities:  

Mesh:

Substances:

Year:  2012        PMID: 23011907     DOI: 10.1002/jmri.23821

Source DB:  PubMed          Journal:  J Magn Reson Imaging        ISSN: 1053-1807            Impact factor:   4.813


  5 in total

1.  Free-breathing whole-heart 3D cine magnetic resonance imaging with prospective respiratory motion compensation.

Authors:  Mehdi H Moghari; Ashita Barthur; Maria E Amaral; Tal Geva; Andrew J Powell
Journal:  Magn Reson Med       Date:  2017-12-08       Impact factor: 4.668

2.  Highly-accelerated self-gated free-breathing 3D cardiac cine MRI: validation in assessment of left ventricular function.

Authors:  Jing Liu; Li Feng; Hsin-Wei Shen; Chengcheng Zhu; Yan Wang; Kanae Mukai; Gabriel C Brooks; Karen Ordovas; David Saloner
Journal:  MAGMA       Date:  2017-01-24       Impact factor: 2.310

3.  Free-breathing Cardiorespiratory Synchronized Cine MRI for Assessment of Left and Right Ventricular Volume and Function in Sedated Children and Adolescents with Impaired Breath-holding Capacity.

Authors:  Amol S Pednekar; Siddharth Jadhav; Cory Noel; Prakash Masand
Journal:  Radiol Cardiothorac Imaging       Date:  2019-06-06

4.  Two-center clinical validation and quantitative assessment of respiratory triggered retrospectively cardiac gated balanced-SSFP cine cardiovascular magnetic resonance imaging in adults.

Authors:  Amol S Pednekar; Hui Wang; Scott Flamm; Benjamin Y Cheong; Raja Muthupillai
Journal:  J Cardiovasc Magn Reson       Date:  2018-06-28       Impact factor: 5.364

5.  Ferumoxytol-enhanced 4D multiphase, steady-state imaging with magnetic resonance in congenital heart disease: ventricular volume and function across 2D and 3D software platforms.

Authors:  Takegawa Yoshida; Joseph J Chen; Bill Zhou; J Paul Finn; Peng Hu; Kim-Lien Nguyen
Journal:  Quant Imaging Med Surg       Date:  2022-09
  5 in total