Interfractional trend analysis of dose differences based on 2D transit portal dosimetry.

L C G G Persoon1, S M J J G Nijsten, F J Wilbrink, M Podesta, J A D Snaith, T Lustberg, W J C van Elmpt, F van Gils, F Verhaegen.   

Abstract

Dose delivery of a radiotherapy treatment can be influenced by a number of factors. It has been demonstrated that the electronic portal imaging device (EPID) is valuable for transit portal dosimetry verification. Patient related dose differences can emerge at any time during treatment and can be categorized in two types: (1) systematic-appearing repeatedly, (2) random-appearing sporadically during treatment. The aim of this study is to investigate how systematic and random information appears in 2D transit dose distributions measured in the EPID plane over the entire course of a treatment and how this information can be used to examine interfractional trends, building toward a methodology to support adaptive radiotherapy. To create a trend overview of the interfractional changes in transit dose, the predicted portal dose for the different beams is compared to a measured portal dose using a γ evaluation. For each beam of the delivered fraction, information is extracted from the γ images to differentiate systematic from random dose delivery errors. From the systematic differences of a fraction for a projected anatomical structures, several metrics are extracted like percentage pixels with |γ| > 1. We demonstrate for four example cases the trends and dose difference causes which can be detected with this method. Two sample prostate cases show the occurrence of a random and systematic difference and identify the organ that causes the difference. In a lung cancer case a trend is shown of a rapidly diminishing atelectasis (lung fluid) during the course of treatment, which was detected with this trend analysis method. The final example is a breast cancer case where we show the influence of set-up differences on the 2D transit dose. A method is presented based on 2D portal transit dosimetry to record dose changes throughout the course of treatment, and to allow trend analysis of dose discrepancies. We show in example cases that this method can identify the causes of dose delivery differences and that treatment adaptation can be triggered as a result. It provides an important element toward informed decision-making for adaptive radiotherapy.

Entities:  

Mesh:

Year:  2012        PMID: 23001452     DOI: 10.1088/0031-9155/57/20/6445

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  8 in total

1.  A novel approach to SBRT patient quality assurance using EPID-based real-time transit dosimetry : A step to QA with in vivo EPID dosimetry.

Authors:  Christos Moustakis; Fatemeh Ebrahimi Tazehmahalleh; Khaled Elsayad; Francis Fezeu; Sergiu Scobioala
Journal:  Strahlenther Onkol       Date:  2020-01-10       Impact factor: 3.621

2.  A Simple Method for 2-D In Vivo Dosimetry by Portal Imaging.

Authors:  Stefano Peca; Derek Wilson Brown; Wendy Lani Smith
Journal:  Technol Cancer Res Treat       Date:  2017-06-06

3.  A Feasibility Study for in vivo Dosimetry Procedure in Routine Clinical Practice.

Authors:  Maria D Falco; Stefano Giancaterino; Andrea De Nicola; Nico Adorante; Ramon Gimenez De Lorenzo; Monica Di Tommaso; Annamaria Vinciguerra; Marianna Trignani; Francesca Perrotti; Albina Allajbej; Andrea Fidanzio; Francesca Greco; Mattia Grusio; Domenico Genovesi; Angelo Piermattei
Journal:  Technol Cancer Res Treat       Date:  2018-01-01

4.  The effect of respiratory motion on electronic portal imaging device dosimetry.

Authors:  Andrew L Fielding; Jessica Benitez Mendieta; Sarah Maxwell; Catherine Jones
Journal:  J Appl Clin Med Phys       Date:  2019-02-05       Impact factor: 2.102

5.  First Report of the Clinical Use of a Commercial Automated System for Daily Patient QA Using EPID Exit Images.

Authors:  Arthur J Olch; Kyle O'Meara; Kenneth K Wong
Journal:  Adv Radiat Oncol       Date:  2019-04-12

6.  Evaluation of automated pre-treatment and transit in-vivo dosimetry in radiotherapy using empirically determined parameters.

Authors:  Evy Bossuyt; Reinhilde Weytjens; Daan Nevens; Sarah De Vos; Dirk Verellen
Journal:  Phys Imaging Radiat Oncol       Date:  2020-11-09

7.  Investigation of a real-time EPID-based patient dose monitoring safety system using site-specific control limits.

Authors:  Todsaporn Fuangrod; Peter B Greer; Henry C Woodruff; John Simpson; Shashank Bhatia; Benjamin Zwan; Timothy A vanBeek; Boyd M C McCurdy; Richard H Middleton
Journal:  Radiat Oncol       Date:  2016-08-12       Impact factor: 3.481

8.  Two-dimensional in vivo dose verification using portal imaging and correlation ratios.

Authors:  Stefano Peca; Derek W Brown
Journal:  J Appl Clin Med Phys       Date:  2014-07-08       Impact factor: 2.102

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.