Double tuning a single input probe for heteronuclear NMR spectroscopy at low field.

Sasidhar Tadanki1, Raul D Colon, Jay Moore, Kevin W Waddell.   

Abstract

Applications of PASADENA in biomedicine are continuing to emerge due to recent demonstrations that hyperpolarized metabolic substrates and the corresponding reaction products persist sufficiently long to be detected in vivo. Biomedical applications of PASADENA typically differ from their basic science counterparts in that the polarization endowed by addition of parahydrogen is usually transferred from nascent protons to coupled storage nuclei for subsequent detection on a higher field imaging instrument. These pre-imaging preparations usually take place at low field, but commercial spectrometers capable of heteronuclear pulsed NMR at frequencies in the range of 100 kHz to 1 MHz are scarce though, in comparison to single channel consoles in that field regime. Reported here is a probe circuit that can be used in conjunction with a phase and amplitude modulation scheme we have developed called PANORAMIC (Precession And Nutation for Observing Rotations At Multiple Intervals about the Carrier), that expands a single channel console capability to double or generally multiple resonance with minimal hardware modifications. The demands of this application are geared towards uniform preparation, and since the hyperpolarized molecules are being detected externally at high field, detection sensitivity is secondary to applied field uniformity over a large reaction volume to accommodate heterogeneous chemistry of gas molecules at a liquid interface. The probe circuit was therefore configured with a large (40 mL) Helmholtz sample coil for uniformity, and double-tuned to the Larmor precession frequencies of (13)C/(1)H (128/510 kHz) within a custom solenoidal electromagnet at a static field of 12 mT. Traditional (on-resonant) as well as PANORAMIC NMR signals with signal to noise ratios of approximately 75 have been routinely acquired with this probe and spectrometer setup from 1024 repetitions on the high frequency channel. The proton excitation pulse width was 240 μs at 6.31 W, compared to a carbon-13 pulse width of 220 μs at 2.51 W. When PANORAMIC refocusing waveforms were transmitted at a carrier frequency of 319 kHz, integrated signal intensities from a spin-echo sequence at both proton (510 kHz) and carbon-13 (128 kHz) frequencies were within experimental error to block pulse analogs transmitted on resonance. We anticipate that this probe circuit design could be extended to higher and lower frequencies, and that when used in conjunction with PANORAMIC phase and amplitude modulated arrays, will enable low field imaging consoles to serve as multinuclear consoles.
Copyright © 2012 Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2012        PMID: 22975236      PMCID: PMC4118687          DOI: 10.1016/j.jmr.2012.06.008

Source DB:  PubMed          Journal:  J Magn Reson        ISSN: 1090-7807            Impact factor:   2.229


  8 in total

1.  Reducing the duration of broadband excitation pulses using optimal control with limited RF amplitude.

Authors:  Thomas E Skinner; Timo O Reiss; Burkhard Luy; Navin Khaneja; Steffen J Glaser
Journal:  J Magn Reson       Date:  2004-03       Impact factor: 2.229

2.  Transformation of symmetrization order to nuclear-spin magnetization by chemical reaction and nuclear magnetic resonance.

Authors: 
Journal:  Phys Rev Lett       Date:  1986-11-24       Impact factor: 9.161

Review 3.  Metabolic imaging and other applications of hyperpolarized 13C1.

Authors:  Klaes Golman; J Stefan Petersson
Journal:  Acad Radiol       Date:  2006-08       Impact factor: 3.173

4.  A dual-frequency circularly polarizing whole-body MR antenna for 69/170 MHz.

Authors:  W Dürr; S Rauch
Journal:  Magn Reson Med       Date:  1991-06       Impact factor: 4.668

5.  Single-input double-tuned Foster-type probe circuit.

Authors:  S Kan; P Jehenson; A Leroy-Willig
Journal:  Magn Reson Med       Date:  1992-07       Impact factor: 4.668

6.  Detecting tumor response to treatment using hyperpolarized 13C magnetic resonance imaging and spectroscopy.

Authors:  Sam E Day; Mikko I Kettunen; Ferdia A Gallagher; De-En Hu; Mathilde Lerche; Jan Wolber; Klaes Golman; Jan Henrik Ardenkjaer-Larsen; Kevin M Brindle
Journal:  Nat Med       Date:  2007-10-28       Impact factor: 53.440

7.  Reversible interactions with para-hydrogen enhance NMR sensitivity by polarization transfer.

Authors:  Ralph W Adams; Juan A Aguilar; Kevin D Atkinson; Michael J Cowley; Paul I P Elliott; Simon B Duckett; Gary G R Green; Iman G Khazal; Joaquín López-Serrano; David C Williamson
Journal:  Science       Date:  2009-03-27       Impact factor: 47.728

8.  Hyperpolarized 13C lactate, pyruvate, and alanine: noninvasive biomarkers for prostate cancer detection and grading.

Authors:  Mark J Albers; Robert Bok; Albert P Chen; Charles H Cunningham; Matt L Zierhut; Vickie Yi Zhang; Susan J Kohler; James Tropp; Ralph E Hurd; Yi-Fen Yen; Sarah J Nelson; Daniel B Vigneron; John Kurhanewicz
Journal:  Cancer Res       Date:  2008-10-15       Impact factor: 12.701

  8 in total
  3 in total

1.  Heteronuclear refocusing by nonlinear phase and amplitude modulation on a single transmitter channel.

Authors:  Jay Moore; Raul D Colón; Sasidhar Tadanki; Kevin W Waddell
Journal:  J Magn Reson       Date:  2014-06-02       Impact factor: 2.229

2.  An open-source, low-cost NMR spectrometer operating in the mT field regime.

Authors:  Nicholas Bryden; Michael Antonacci; Michele Kelley; Rosa T Branca
Journal:  J Magn Reson       Date:  2021-09-27       Impact factor: 2.734

3.  Untuned broadband spiral micro-coils achieve sensitive multi-nuclear NMR TX/RX from microfluidic samples.

Authors:  Hossein Davoodi; Nurdiana Nordin; Hirokazu Munakata; Jan G Korvink; Neil MacKinnon; Vlad Badilita
Journal:  Sci Rep       Date:  2021-04-08       Impact factor: 4.379

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.