Literature DB >> 22974389

Corneal thickness after overnight wear of an intraocular pressure fluctuation contact lens sensor.

Florentina J Freiberg1, Jeanette Lindell, Luisa A-L Thederan, Swetlana Leippi, Yanan Shen, Thomas Klink.   

Abstract

PURPOSE: To assess the effect of overnight wear of a contact lens-based sensor (CLS) for monitoring of 24-hr intraocular pressure (IOP) fluctuations on central corneal thickness (CCT).
MATERIALS AND METHODS: Changes in the CCT, mid-peripheral corneal thickness and central corneal radius (CCR) during overnight CLS wear in 20 eligible patients with ocular hypertension or established glaucoma were prospectively studied using ultrasound pachymetry and topography. Corneal thickness and CCR changes were evaluated from pre-to-postsleep, with the fellow eye as control. Paired t-test or Wilcoxon signed-rank test was used as appropriate and with α = 0.05. Relationship between the IOP profile recorded by the CLS and the pre-to-postsleep corneal thickness differences was assessed using the Spearman correlation coefficient.
RESULTS: After CLS wear, mean CCT had changed from 523 to 537 μm (p = 0.015) in the study eye and from 518 to 522 (p = 0.206) in the fellow eye (n = 15). There was no difference in CCT change between eyes (p = 0.075). There were no statistically significant changes in horizontal or vertical CCR in either eye (p > 0.05 for all). No correlation was found between the pre-to-postsleep differences in the CLS signal and the pre-to-postsleep differences in ultrasound CCT measurements (p = 0.974).
CONCLUSION: The continuous IOP monitoring does not appear to be affected by differences in corneal thickness that occur during overnight CLS wear, although the CLS did induce some corneal swelling. This effect was not statistically significantly different from the control eye and does not seem to influence the CLS IOP profile.
© 2012 The Authors. Acta Ophthalmologica © 2012 Acta Ophthalmologica Scandinavica Foundation.

Entities:  

Mesh:

Year:  2012        PMID: 22974389     DOI: 10.1111/j.1755-3768.2012.02495.x

Source DB:  PubMed          Journal:  Acta Ophthalmol        ISSN: 1755-375X            Impact factor:   3.761


  9 in total

1.  Transient changes in refractive error and corneal tomography after 24-h continuous monitoring of intraocular pressure patterns with a contact lens sensor.

Authors:  Atsuya Miki; Miho Kumoi; Naoyuki Maeda; Shizuka Koh; Kenji Matsushita; Kohji Nishida
Journal:  Jpn J Ophthalmol       Date:  2020-02-13       Impact factor: 2.447

2.  Association of Ambulatory Blood Pressure and Other Factors With Intraocular Pressure-Related 24-Hour Contact Lens Sensor Profile in Untreated Glaucoma.

Authors:  Kazuki Nakazawa; Tomomi Higashide; Shunsuke Tsuchiya; Satomi Shioya; Masahiko Okayama; Kazuhisa Sugiyama
Journal:  Transl Vis Sci Technol       Date:  2022-10-03       Impact factor: 3.048

3.  Analysis of continuous 24-hour intraocular pressure patterns in glaucoma.

Authors:  Kaweh Mansouri; John H K Liu; Robert N Weinreb; Ali Tafreshi; Felipe A Medeiros
Journal:  Invest Ophthalmol Vis Sci       Date:  2012-12-13       Impact factor: 4.799

4.  Efficacy of a contact lens sensor for monitoring 24-h intraocular pressure related patterns.

Authors:  Kaweh Mansouri; Robert N Weinreb; John H K Liu
Journal:  PLoS One       Date:  2015-05-05       Impact factor: 3.240

5.  Estimation of 24-Hour Intraocular Pressure Peak Timing and Variation Using a Contact Lens Sensor.

Authors:  John H K Liu; Kaweh Mansouri; Robert N Weinreb
Journal:  PLoS One       Date:  2015-06-15       Impact factor: 3.240

6.  The road ahead to continuous 24-hour intraocular pressure monitoring in glaucoma.

Authors:  Kaweh Mansouri
Journal:  J Ophthalmic Vis Res       Date:  2014-04

7.  Twenty-Four-Hour Contact Lens Sensor Monitoring of Aqueous Humor Dynamics in Surgically or Medically Treated Glaucoma Patients.

Authors:  Chiara Posarelli; Pierluigi Ortenzio; Antonio Ferreras; Mario Domenico Toro; Andrea Passani; Pasquale Loiudice; Francesco Oddone; Giamberto Casini; Michele Figus
Journal:  J Ophthalmol       Date:  2019-01-27       Impact factor: 1.909

Review 8.  The Application of a Contact Lens Sensor in Detecting 24-Hour Intraocular Pressure-Related Patterns.

Authors:  Sarah C Xu; Angela C Gauthier; Ji Liu
Journal:  J Ophthalmol       Date:  2016-07-25       Impact factor: 1.909

9.  Comparison of intraocular pressure fluctuations before and after ab interno trabeculectomy in pseudoexfoliation glaucoma patients.

Authors:  Naoki Tojo; Shinya Abe; Mari Miyakoshi; Atsushi Hayashi
Journal:  Clin Ophthalmol       Date:  2017-09-14
  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.