Literature DB >> 22972684

A theoretical and experimental comparison of different techniques for B₁ mapping at very high fields.

Rolf Pohmann1, Klaus Scheffler.   

Abstract

With the increasing use of ultrahigh-field MR with multiple transmit channels, mapping of the B₁(+) field has become a critical factor in many studies, leading to the publication of a large number of sequences for the measurement of the flip angle in recent years. In this article, the accuracy, precision and practicability of some of the most prominent of these techniques are investigated both theoretically, using error propagation computations and Monte-Carlo simulations, and experimentally for different settings. For an exemplary experiment, which is typical for high-field applications, the flip angle uncertainty is calculated and measured for two- and three-dimensional acquisitions for techniques based on both magnitude and phase data. Simulated and measured results show good agreement. An experimental assessment of T₁ and B₀ dependence yields weak variations with these parameters for only a few of the sequences. Measurements on human scanners show crucial influences of specific absorption rate limitations, especially at ultrahigh field.
Copyright © 2012 John Wiley & Sons, Ltd.

Entities:  

Mesh:

Year:  2012        PMID: 22972684     DOI: 10.1002/nbm.2844

Source DB:  PubMed          Journal:  NMR Biomed        ISSN: 0952-3480            Impact factor:   4.044


  12 in total

1.  Tissue electrical property mapping from zero echo-time magnetic resonance imaging.

Authors:  Seung-Kyun Lee; Selaka Bulumulla; Florian Wiesinger; Laura Sacolick; Wei Sun; Ileana Hancu
Journal:  IEEE Trans Med Imaging       Date:  2014-10-08       Impact factor: 10.048

2.  Accuracy, repeatability, and interplatform reproducibility of T1 quantification methods used for DCE-MRI: Results from a multicenter phantom study.

Authors:  Octavia Bane; Stefanie J Hectors; Mathilde Wagner; Lori L Arlinghaus; Madhava P Aryal; Yue Cao; Thomas L Chenevert; Fiona Fennessy; Wei Huang; Nola M Hylton; Jayashree Kalpathy-Cramer; Kathryn E Keenan; Dariya I Malyarenko; Robert V Mulkern; David C Newitt; Stephen E Russek; Karl F Stupic; Alina Tudorica; Lisa J Wilmes; Thomas E Yankeelov; Yi-Fei Yen; Michael A Boss; Bachir Taouli
Journal:  Magn Reson Med       Date:  2017-09-14       Impact factor: 4.668

3.  Motion-robust cardiac B1+ mapping at 3T using interleaved bloch-siegert shifts.

Authors:  Sebastian Weingärtner; Fabian Zimmer; Gregory J Metzger; Kâmil Uğurbil; Pierre-Francois Van de Moortele; Mehmet Akçakaya
Journal:  Magn Reson Med       Date:  2016-09-07       Impact factor: 4.668

4.  A statistical analysis of the Bloch-Siegert B1 mapping technique.

Authors:  Daniel J Park; Neal K Bangerter; Ahsan Javed; Joshua Kaggie; Mohammad Mehdi Khalighi; Glen R Morrell
Journal:  Phys Med Biol       Date:  2013-07-31       Impact factor: 3.609

5.  Analysis of the Precision of Variable Flip Angle T1 Mapping with Emphasis on the Noise Propagated from RF Transmit Field Maps.

Authors:  Yoojin Lee; Martina F Callaghan; Zoltan Nagy
Journal:  Front Neurosci       Date:  2017-03-09       Impact factor: 4.677

6.  Accuracy and precision of electrical permittivity mapping at 3T: the impact of three B 1 + mapping techniques.

Authors:  Soraya Gavazzi; Cornelis A T van den Berg; Alessandro Sbrizzi; H Petra Kok; Lukas J A Stalpers; Jan J W Lagendijk; Hans Crezee; Astrid L H M W van Lier
Journal:  Magn Reson Med       Date:  2019-02-08       Impact factor: 4.668

7.  In vivo proton magnetic resonance spectroscopic imaging of the healthy human brain at 9.4 T: initial experience.

Authors:  Grzegorz L Chadzynski; Rolf Pohmann; Gunamony Shajan; Rupert Kolb; Sotirios Bisdas; Uwe Klose; Klaus Scheffler
Journal:  MAGMA       Date:  2014-09-24       Impact factor: 2.310

8.  Single acquisition electrical property mapping based on relative coil sensitivities: A proof-of-concept demonstration.

Authors:  José P Marques; Daniel K Sodickson; Ozlem Ipek; Christopher M Collins; Rolf Gruetter
Journal:  Magn Reson Med       Date:  2014-08-05       Impact factor: 4.668

9.  Large dynamic range relative B1+ mapping.

Authors:  Francesco Padormo; Aaron T Hess; Paul Aljabar; Shaihan J Malik; Peter Jezzard; Matthew D Robson; Joseph V Hajnal; Peter J Koopmans
Journal:  Magn Reson Med       Date:  2015-08-26       Impact factor: 4.668

10.  The impact of B1+ correction on MP2RAGE cortical T1 and apparent cortical thickness at 7T.

Authors:  Roy A M Haast; Dimo Ivanov; Kâmil Uludağ
Journal:  Hum Brain Mapp       Date:  2018-02-18       Impact factor: 5.038

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.