Literature DB >> 22958773

Intraprocedural angiographic CT as a valuable tool in the course of endovascular treatment of direct sinus cavernous fistulas.

P Gölitz1, T Struffert, M Arc Saake, F Knossalla, A Doerfler.   

Abstract

This investigation aimed to demonstrate the potential of intraprocedural angiographic CT in monitoring complex endovascular coil embolization of direct carotid cavernous fistulas. Angiographic CT was performed as a dual rotational 5 s run with intraarterial contrast medium injection in two patients during endovascular coil embolization of direct carotid cavernous fistulas. Intraprocedural angiographic CT was considered helpful if conventional 2D series were not conclusive concerning coil position or if a precise delineation of the parent artery was impossible due to a complex anatomy or overlying coil material. During postprocessing multiplanar reformatted and dual volume images of angiographic CT were reconstructed. Angiographic CT turned out to be superior in the intraprocedural visualization of accidental coil migration into the parent artery where conventional 2D-DSA series failed to reliably detect coil protrusion. The delineation of coil protrusion by angiographic CT allowed immediate correct coil repositioning to prevent parent artery compromising. Angiographic CT can function as a valuable intraprocedurally feasible tool during complex coil embolizations of direct carotid cavernous fistulas. It allows the precise visualization of the cerebral vasculature and any accidental coil protrusion can be determined accurately in cases where conventional 2D-DSA series are unclear or compromised. Thus angiographic CT might contribute substantially to reduce procedural complications and to increase safety in the management of endovascular treatment of direct carotid cavernous fistulas.

Entities:  

Mesh:

Year:  2012        PMID: 22958773      PMCID: PMC3442308          DOI: 10.1177/159101991201800313

Source DB:  PubMed          Journal:  Interv Neuroradiol        ISSN: 1591-0199            Impact factor:   1.610


  15 in total

1.  Endovascular therapy of arteriovenous fistulae with electrolytically detachable coils.

Authors:  O Jansen; A Dörfler; M Forsting; M Hartmann; R von Kummer; V Tronnier; K Sartor
Journal:  Neuroradiology       Date:  1999-12       Impact factor: 2.804

2.  Treatment of post-traumatic carotico-cavernous fistulae using electrolytically detachable coils: technical aspects and preliminary experience.

Authors:  G Bavinzski; M Killer; A Gruber; B Richling
Journal:  Neuroradiology       Date:  1997-02       Impact factor: 2.804

3.  Visualisation of intracerebral haemorrhage with flat-detector CT compared to multislice CT: results in 44 cases.

Authors:  Tobias Struffert; Gregor Richter; Tobias Engelhorn; Marc Doelken; Philipp Goelitz; Willi A Kalender; Oliver Ganslandt; Arnd Doerfler
Journal:  Eur Radiol       Date:  2008-09-24       Impact factor: 5.315

4.  Posttraumatic carotid cavernous fistula: frequency analysis of signs, symptoms, and disability outcomes after angiographic embolization.

Authors:  T S Fabian; J D Woody; D L Ciraulo; E D Lett; R F Phlegar; D E Barker; R P Burns
Journal:  J Trauma       Date:  1999-08

5.  Endovascular treatment of high-flow carotid cavernous fistulas by stent-assisted coil placement.

Authors:  Fanny E Morón; Richard P Klucznik; Michel E Mawad; Charles M Strother
Journal:  AJNR Am J Neuroradiol       Date:  2005 Jun-Jul       Impact factor: 3.825

6.  Endovascular treatment of direct carotid cavernous fistulae: a pictorial review.

Authors:  Arun K Gupta; Sukalyan Purkayastha; T Krishnamoorthy; Narendra K Bodhey; T R Kapilamoorthy; C Kesavadas; Bejoy Thomas
Journal:  Neuroradiology       Date:  2006-09-13       Impact factor: 2.804

7.  Endovascular treatment of post-traumatic direct carotid-cavernous fistulas: A single-center experience.

Authors:  Wu Wang; Yong-Dong Li; Ming-Hua Li; Hua-Qiao Tan; Bin-Xian Gu; Ju Wang; Pei-Lai Zhang
Journal:  J Clin Neurosci       Date:  2011-01       Impact factor: 1.961

8.  Flat panel detector angiographic CT for stent-assisted coil embolization of broad-based cerebral aneurysms.

Authors:  G Richter; T Engelhorn; T Struffert; M Doelken; O Ganslandt; J Hornegger; W A Kalender; A Doerfler
Journal:  AJNR Am J Neuroradiol       Date:  2007-09-24       Impact factor: 3.825

9.  High-flow, small-hole arteriovenous fistulas: treatment with electrodetachable coils.

Authors:  G Guglielmi; F Viñuela; G Duckwiler; J Dion; A Stocker
Journal:  AJNR Am J Neuroradiol       Date:  1995-02       Impact factor: 3.825

10.  The use of electrolytically detachable coils in treating high-flow arteriovenous fistulas.

Authors:  G M Nesbit; S L Barnwell
Journal:  AJNR Am J Neuroradiol       Date:  1998-09       Impact factor: 3.825

View more
  1 in total

1.  Angiographic C-arm CT visualization of the Woven EndoBridge cerebral aneurysm embolization device (WEB): first experience in an animal aneurysm model.

Authors:  T Struffert; S Lang; E Adamek; T Engelhorn; C M Strother; A Doerfler
Journal:  Clin Neuroradiol       Date:  2013-05-28       Impact factor: 3.649

  1 in total