Literature DB >> 22958765

CE-MRA for follow-up of aneurysms post stent-assisted coiling.

R Agid1, M Schaaf, Ri Farb.   

Abstract

This study compared the accuracy of contrast-enhanced MR angiography (CE-MRA) to intra-arterial cerebral angiography (IA-DSA) for assessment of intracranial aneurysms after stent-assisted coiling and to check if the presence of a stent in the parent artery diminishes the accuracy of CE-MRA. Consecutive patients with cerebral aneurysms treated by stent-assisted coiling were evaluated retrospectively. Matching follow-up CE-MRA and IA-DSA were evaluated separately. Evaluation included the presence of aneurysmal remnant, patency and stenosis of parent artery. Twenty-seven patients with 28 aneurysms and 33 matched CE-MRA and IA-DSA studies were evaluated. Nineteen aneurysmal remnants were seen on CE-MRA and 16 on IA-DSA. CE-MRA diagnosed three aneurysmal remnants not appreciated on IA-DSA. Five other remnants were larger on CE-MRA than IA-DSA. None of the remnants were missed on CE-MRA. Parent arteries were patent on both modalities. CE-MRA showed false stenosis of the stented artery in six cases and exaggerated stenosis in two. In 18 cases, CE-MRA showed a short focal "pseudo-stenosis" where the stent's marker bands were located. This was noted whenever the stent's marker bands were located in an artery with luminal diameter ≤2 mm and was called "marker band effect". CE-MRA is an accurate technique for follow-up of aneurysms post stent-assisted coiling with excellent depiction of remnants in spite of the presence of a stent. Apparent stenosis of the stented parent artery on CE-MRA is often false or exaggerated. "Marker band effect" should be recognized as an artifact that appears when stent's marker bands are in a small artery.

Entities:  

Mesh:

Substances:

Year:  2012        PMID: 22958765      PMCID: PMC3442300          DOI: 10.1177/159101991201800305

Source DB:  PubMed          Journal:  Interv Neuroradiol        ISSN: 1591-0199            Impact factor:   1.610


  21 in total

1.  Improved lumen visualization in metallic vascular implants by reducing RF artifacts.

Authors:  Lambertus W Bartels; Chris J G Bakker; Max A Viergever
Journal:  Magn Reson Med       Date:  2002-01       Impact factor: 4.668

Review 2.  The role of magnetic susceptibility in magnetic resonance imaging: MRI magnetic compatibility of the first and second kinds.

Authors:  J F Schenck
Journal:  Med Phys       Date:  1996-06       Impact factor: 4.071

3.  MR artifacts, heat production, and ferromagnetism of Guglielmi detachable coils.

Authors:  J Hartman; T Nguyen; D Larsen; G P Teitelbaum
Journal:  AJNR Am J Neuroradiol       Date:  1997-03       Impact factor: 3.825

4.  MR angiography at 3T versus digital subtraction angiography in the follow-up of intracranial aneurysms treated with detachable coils.

Authors:  Charles B L M Majoie; Marieke E Sprengers; Willem Jan J van Rooij; Cristina Lavini; Menno Sluzewski; Jeroen C van Rijn; Gerard J den Heeten
Journal:  AJNR Am J Neuroradiol       Date:  2005 Jun-Jul       Impact factor: 3.825

5.  Surveillance of intracranial aneurysms treated with detachable coils: a comparison of MRA techniques.

Authors:  Richard I Farb; Shudeshna Nag; James N Scott; Robert A Willinsky; Thomas R Marotta; Walter J Montanera; George Tomlinson; Karel G Terbrugge
Journal:  Neuroradiology       Date:  2005-06-10       Impact factor: 2.804

6.  Three-dimensional time-of-flight MR angiography for evaluation of intracranial aneurysms after endosaccular packing with Guglielmi detachable coils: comparison with 3D digital subtraction angiography.

Authors:  Mika Okahara; Hiro Kiyosue; Yuzo Hori; Masanori Yamashita; Hirofumi Nagatomi; Hiromu Mori
Journal:  Eur Radiol       Date:  2004-04-21       Impact factor: 5.315

7.  Time-of-flight MR angiography targeted to coiled intracranial aneurysms is more sensitive to residual flow than is digital subtraction angiography.

Authors:  Naoaki Yamada; Katsuhiko Hayashi; Kenichi Murao; Masahiro Higashi; Koji Iihara
Journal:  AJNR Am J Neuroradiol       Date:  2004-08       Impact factor: 3.825

Review 8.  Neurologic complications of cerebral angiography: prospective analysis of 2,899 procedures and review of the literature.

Authors:  Robert A Willinsky; Steve M Taylor; Karel TerBrugge; Richard I Farb; George Tomlinson; Walter Montanera
Journal:  Radiology       Date:  2003-03-13       Impact factor: 11.105

Review 9.  Coiling of intracranial aneurysms: a systematic review on initial occlusion and reopening and retreatment rates.

Authors:  Sandra P Ferns; Marieke E S Sprengers; Willem Jan van Rooij; Gabriël J E Rinkel; Jeroen C van Rijn; Shandra Bipat; Menno Sluzewski; Charles B L M Majoie
Journal:  Stroke       Date:  2009-06-11       Impact factor: 7.914

10.  International subarachnoid aneurysm trial (ISAT) of neurosurgical clipping versus endovascular coiling in 2143 patients with ruptured intracranial aneurysms: a randomised comparison of effects on survival, dependency, seizures, rebleeding, subgroups, and aneurysm occlusion.

Authors:  Andrew J Molyneux; Richard S C Kerr; Ly-Mee Yu; Mike Clarke; Mary Sneade; Julia A Yarnold; Peter Sandercock
Journal:  Lancet       Date:  2005 Sep 3-9       Impact factor: 79.321

View more
  14 in total

1.  Evaluation of CTA, time-resolved 4D CE-MRA and DSA in the follow-up of an intracranial aneurysm treated with a flow diverter stent: Experience from a single case.

Authors:  Georgios Kapsas; Caterina Budai; Francesco Toni; Francesco Patruno; Anna Federica Marliani; Marco Leonardi; Luigi Cirillo
Journal:  Interv Neuroradiol       Date:  2015-02       Impact factor: 1.610

2.  Contrast-Enhanced and Time-of-Flight MRA at 3T Compared with DSA for the Follow-Up of Intracranial Aneurysms Treated with the WEB Device.

Authors:  C Timsit; S Soize; A Benaissa; C Portefaix; J-Y Gauvrit; L Pierot
Journal:  AJNR Am J Neuroradiol       Date:  2016-04-21       Impact factor: 3.825

3.  Pointwise Encoding Time Reduction with Radial Acquisition with Subtraction-Based MRA during the Follow-Up of Stent-Assisted Coil Embolization of Anterior Circulation Aneurysms.

Authors:  Y J Heo; H W Jeong; J W Baek; S T Kim; Y G Jeong; J Y Lee; S-C Jin
Journal:  AJNR Am J Neuroradiol       Date:  2019-04-11       Impact factor: 3.825

4.  Usefulness of Non-Contrast-Enhanced MR Angiography Using a Silent Scan for Follow-Up after Y-Configuration Stent-Assisted Coil Embolization for Basilar Tip Aneurysms.

Authors:  N Takano; M Suzuki; R Irie; M Yamamoto; N Hamasaki; K Kamagata; K K Kumamaru; M Hori; H Oishi; S Aoki
Journal:  AJNR Am J Neuroradiol       Date:  2016-12-22       Impact factor: 3.825

5.  Usefulness of Silent MR Angiography for Intracranial Aneurysms Treated with a Flow-Diverter Device.

Authors:  H Oishi; T Fujii; M Suzuki; N Takano; K Teranishi; K Yatomi; T Kitamura; M Yamamoto; S Aoki; H Arai
Journal:  AJNR Am J Neuroradiol       Date:  2019-05-02       Impact factor: 3.825

6.  Non-Contrast-Enhanced Silent Scan MR Angiography of Intracranial Anterior Circulation Aneurysms Treated with a Low-Profile Visualized Intraluminal Support Device.

Authors:  N Takano; M Suzuki; R Irie; M Yamamoto; K Teranishi; K Yatomi; N Hamasaki; K K Kumamaru; M Hori; H Oishi; S Aoki
Journal:  AJNR Am J Neuroradiol       Date:  2017-05-18       Impact factor: 3.825

7.  Contrast-Enhanced and Time-of-Flight MR Angiographic Assessment of Endovascular Coiled Intracranial Aneurysms at 1.5 T.

Authors:  Akin Levent; Ihsan Yuce; Suat Eren; Omer Ozyigit; Mecit Kantarci
Journal:  Interv Neuroradiol       Date:  2014-12-05       Impact factor: 1.610

8.  Will Fluoroscopic Follow-up after Stent-Assisted Coiling of Cerebral Aneurysms Provide Information on Recanalization?

Authors:  Hyun Ho Oh; Cheolkyu Jung; Tae Hong Lee; Bae Ju Kwon; Young Kim; Kyu Chang Lee
Journal:  Interv Neuroradiol       Date:  2014-12-05       Impact factor: 1.610

9.  New technique: the use of the THRIVE sequence in the follow-up of patients who received endovascular intracranial aneurysm treatment.

Authors:  Emre Mırçık; Bahattin Hakyemez
Journal:  Neuroradiology       Date:  2020-09-11       Impact factor: 2.804

10.  Stent-assisted embolization of recurrent or residual intracranial aneurysms.

Authors:  Olli I Tähtinen; Hannu I Manninen; Ritva L Vanninen; Riitta Rautio; Arto Haapanen; Janne Seppänen; Tero Niskakangas; Jaakko Rinne; Leo Keski-Nisula
Journal:  Neuroradiology       Date:  2013-07-17       Impact factor: 2.804

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.