| Literature DB >> 22949980 |
Duk-Dong Ko1, Hyun Kang, So-Young Yang, Hwa-Yong Shin, Chong Wha Baek, Yong Hun Jung, Young-Cheol Woo, Jin-Yun Kim, Gill Hoi Koo, Seong-Deok Kim.
Abstract
BACKGROUND: Optiscope™ is a newly developed video stylet device. This study evaluated and compared the hemodynamic changes observed after endotracheal intubation with video stylet and after conventional laryngoscopic endotracheal intubation.Entities:
Keywords: Bronchoscopes; Endotracheal intubation; Fiberoptics; Hemodynamics; Laryngoscope; Video recording
Year: 2012 PMID: 22949980 PMCID: PMC3427805 DOI: 10.4097/kjae.2012.63.2.130
Source DB: PubMed Journal: Korean J Anesthesiol ISSN: 2005-6419
Fig. 1Monitor view of entire glottis.
Patient Characteristics & Airway Observations
Values are presented as mean±SD, median (interquartile range) or absolute number. n: absolute number, BMI: body mass index, ASA: American Society of Anesthesiologist classification, POGO: percentage of glottic opening. *Mann-Whitney U test was used and presented as median (interquartile range) because of abnormal distribution. †P < 0.05 compared with Group S.
Fig. 2Changes of systolic blood pressure (SBP) before and after intubation (mean ± standard error). Group S: Optiscope using group, Group L: Machintosh laryngoscope using group. Pre: pre-induction value. 1, 3, 5 min: value at 1, 3, 5 minute after intubation. There no significant differences between two groups. *P < 0.05 compared to pre-induction value.
Fig. 3Changes of mean arterial pressure (MAP) before and after intubation (mean ± standard error). Group S: Optiscope using group, Group L: Machintosh laryngoscope using group. Pre: pre-induction value. 1, 3, 5 min: value at 1, 3, 5 minute after intubation. There no significant differences between two groups. *P < 0.05 compared to pre-induction value.
Fig. 4Changes of diatolic blood pressure (DBP) before and after intubation (mean ± standard error). Group S: Optiscope using group, Group L: Machintosh laryngoscope using group. Pre: pre-induction value. 1, 3, 5 min: value at 1, 3, 5 minute after intubation. There no significant differences between two groups. *P < 0.05 compared to pre-induction value.
Fig. 5Changes of heart rate (HR) before and after intubation (mean ± standard error). Group S: Optiscope using group, Group L: Machintosh laryngoscope using group. Pre: pre-induction value. 1, 3, 5 min: value at 1, 3, 5 minute after intubation. There no significant differences between two groups. *P < 0.05 compared to pre-induction value.