Literature DB >> 12598280

Hemodynamic responses among three tracheal intubation devices in normotensive and hypertensive patients.

S Kihara1, J Brimacombe, Y Yaguchi, S Watanabe, N Taguchi, T Komatsuzaki.   

Abstract

UNLABELLED: We compare hemodynamic responses in normotensive and hypertensive anesthetized paralyzed patients among three intubation devices: the Macintosh laryngoscope (LS), the Trachlight lightwand (LW), and the intubating laryngeal mask airway Fastrach (ILM). Seventy-five normotensive and 75 hypertensive patients were randomly assigned to each intubation device (n = 25). Noninvasive systolic blood pressure (SBP) and diastolic blood pressure (DBP) and heart rate (HR) were recorded immediately preinduction, immediately preintubation, and every minute for the first 5 min after the successful intubation. The number of intubation attempts, the time to successful intubation, and any airway injuries were recorded. Pharyngolaryngeal morbidity was assessed 18-24 h after surgery by a blinded investigator. In all groups, there was a reduction in SBP and DBP but no change in HR immediately preintubation compared with baseline values. In all groups, HR increased, but there were no increases in SBP and DBP other than in DBP in the LS/hypertensive group after intubation compared with baseline values. In normotensive patients, there were no differences in any hemodynamic variables among the three devices. In hypertensive patients, SBP and DBP in the LS group were significantly higher than the ILM and LW groups for 2 min after intubation, but there were no differences in HR among the devices. The number of intubation attempts was similar among groups, but intubation time was longer for the ILM group. The incidence of airway injury was more frequent for the ILM than the LS and LW groups (16% versus 0% versus 0%). There were no differences in pharyngolaryngeal morbidity among groups. We conclude that both the ILM and the LW attenuated the hemodynamic stress response to tracheal intubation compared with the LS in hypertensive, but not in normotensive, anesthetized paralyzed patients. IMPLICATIONS: Both the intubating laryngeal mask airway Fastrach and the Trachlight lightwand attenuate the hemodynamic stress response to tracheal intubation compared with the Macintosh laryngoscope in hypertensive, but not in normotensive, anesthetized paralyzed patients.

Entities:  

Mesh:

Year:  2003        PMID: 12598280     DOI: 10.1213/01.ane.0000048706.15720.c9

Source DB:  PubMed          Journal:  Anesth Analg        ISSN: 0003-2999            Impact factor:   5.108


  29 in total

1.  Comparison of cardiac output and hemodynamic responses of intubation among different videolaryngoscopies in normotensive and hypertensive patients.

Authors:  Amro Faez Abdelgawad; Qin-Fang Shi; Mohamed Abo Halawa; Zhi-Lin Wu; Zhou-Yang Wu; Xiang-Dong Chen; Shang-Long Yao
Journal:  J Huazhong Univ Sci Technolog Med Sci       Date:  2015-06-14

2.  Comparison of the effects of various airway devices on hemodynamic response and QTc interval in rabbits under general anesthesia.

Authors:  Huseyin Toman; Mesut Erbas; Hasan Sahin; Hasan Ali Kiraz; Metehan Uzun; Mehmet Akif Ovali
Journal:  J Clin Monit Comput       Date:  2015-01-31       Impact factor: 2.502

3.  Comparison of the Supraglottic Airway Devices Classic, Fastrach and Supreme Laryngeal Mask Airway: A Prospective Randomised Clinical Trial of Efficacy, Safety and Complications.

Authors:  Erdal Kömür; Nurten Bakan; Şenay Göksu Tomruk; Gülşah Karaören; Zelin Topaç Doğan
Journal:  Turk J Anaesthesiol Reanim       Date:  2015-12-01

4.  Effects of lornoxicam on the hemodynamic and catecholamine response to laryngoscopy and tracheal intubation.

Authors:  Mohamed Daabiss; Mohamed Hashish
Journal:  Eur J Clin Pharmacol       Date:  2011-03-03       Impact factor: 2.953

5.  Influence of head flexion after endotracheal intubation on intraocular pressure and cardio-respiratory response in patients undergoing cataract surgery.

Authors:  M Safavi; A Honarmand
Journal:  Ghana Med J       Date:  2008-09

6.  Perfusion index versus non-invasive hemodynamic parameters during insertion of i-gel, classic laryngeal mask airway and endotracheal tube.

Authors:  Hosam M Atef; Salah Abd Fattah; Mohammed Emad Abd Gaffer; Ahamed Abd Al Rahman
Journal:  Indian J Anaesth       Date:  2013-03

7.  A randomized controlled study to evaluate and compare Truview blade with Macintosh blade for laryngoscopy and intubation under general anesthesia.

Authors:  Ramesh T Timanaykar; Lakesh K Anand; Sanjeev Palta
Journal:  J Anaesthesiol Clin Pharmacol       Date:  2011-04

8.  Hemodynamic responses and upper airway morbidity following tracheal intubation in patients with hypertension: conventional laryngoscopy versus an intubating laryngeal mask airway.

Authors:  Elif Bengi Sener; Emre Ustun; Burcu Ustun; Binnur Sarihasan
Journal:  Clinics (Sao Paulo)       Date:  2012       Impact factor: 2.365

9.  Comparison of hemodynamic responses to endotracheal intubation with the GlideScope video laryngoscope and Macintosh laryngoscope in patients undergoing cardiovascular surgery.

Authors:  Gökhan İnangil; Kadir Hakan Cansız; Fuat Gürbüz; Ömer Bakal; Fatma Merih Gökben; Hüseyin Şen
Journal:  Turk Gogus Kalp Damar Cerrahisi Derg       Date:  2018-07-03       Impact factor: 0.332

10.  A comparison of hemodynamic changes after endotracheal intubation by the Optiscope™ and the conventional laryngoscope.

Authors:  Duk-Dong Ko; Hyun Kang; So-Young Yang; Hwa-Yong Shin; Chong Wha Baek; Yong Hun Jung; Young-Cheol Woo; Jin-Yun Kim; Gill Hoi Koo; Seong-Deok Kim
Journal:  Korean J Anesthesiol       Date:  2012-08-14
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.