Evaluation of design parameters of dental implant shape, diameter and length on stress distribution: a finite element analysis.

M Mohammed Ibrahim, C Thulasingam, K S G A Nasser, V Balaji, M Rajakumar, P Rupkumar.   

Abstract

The aim was to evaluate the design parameters of dental implants shape, diameter and length on stress distribution by finite element analysis (FEA).The objectives of the study was to compare the influence of stress distribution in the implants of screw-vent tapered and parallel design by varying the implant diameter with a standard implant length. Six dental implant models have been simulated three-dimensionally. The influence of diameter and length on stress distribution was evaluated by Group I: for screw-vent tapered design (Zimmer Dental Implant Carlsbad, CA, USA) (1) Dental implant model with diameter 3.7 mm and length 13 mm. (2) Dental implant model with diameter 4.1 mm and length 13 mm. (3) Dental implant model with diameter 4.7 mm and length 13 mm. Group II: for parallel design (Zimmer Dental Implant Carlsbad, CA, USA) (4) Dental implant model with diameter 3.7 mm and length 13 mm. (5) Dental implant model with diameter 4.1 mm and length 13 mm. (6) Dental implant model with diameter 4.7 mm and length 13 mm. The 3-D model of the implant was created in the pro-e wildfire 4.0 software by giving various commands. This model was imported to the ANSYS software through IGES (initial graphic exchange specification) file for further analysis. All six models were loaded with a force of 17.1, 114.6 and 23.4 N in a lingual, an axial and disto-mesial direction respectively, simulating average masticatory force in a natural oblique direction, to analyze the stress distribution on these implants. The increase in implant diameter in Group I and Group II from 3.7 to 4.1 mm and from 4.1 to 4.7 mm with constant 13 mm length for screw-vent tapered and parallel design implant resulted in a reduction in maximum value of Von Mises stress in the bone surrounding the implant was statistically significant at 5% level done by student "t" test. The overall maximum value of Von Mises stress was decreased in parallel design implant diameter of 4.7 mm with constant length of 13 mm when compared to screw-vent tapered design implant samples. The results of the FEA computation depend on many individual factors including material properties, boundary conditions interface definition and also on the overall approach to the model. The results depicted that the tapered shape implant design exhibited higher stress levels in bone than the parallel shaped implant design which seemed to be distributing stresses more evenly. The application of a 3-D model simulation with the non-symmetric loading by the masticatory force on a dental implant resulted in a more satisfactory modeling of "clinical reality" than that achieved with 2-D models used in other studies.

Keywords:  Finite element analysis; Optical comparator; Von Mises stress

Year:  2011        PMID: 22942576      PMCID: PMC3175233          DOI: 10.1007/s13191-011-0095-4

Source DB:  PubMed          Journal:  J Indian Prosthodont Soc        ISSN: 0972-4052


  7 in total

Review 1.  Application of finite element analysis in implant dentistry: a review of the literature.

Authors:  J P Geng; K B Tan; G R Liu
Journal:  J Prosthet Dent       Date:  2001-06       Impact factor: 3.426

2.  A mimic osseointegrated implant model for three-dimensional finite element analysis.

Authors:  Y Akagawa; Y Sato; E R Teixeira; N Shindoi; M Wadamoto
Journal:  J Oral Rehabil       Date:  2003-01       Impact factor: 3.837

3.  Mechanics of the tapered interference fit in dental implants.

Authors:  Dinçer Bozkaya; Sinan Müftü
Journal:  J Biomech       Date:  2003-11       Impact factor: 2.712

4.  Influence of implant length and diameter on stress distribution: a finite element analysis.

Authors:  Lucie Himmlová; Tat'jana Dostálová; Alois Kácovský; Svatava Konvicková
Journal:  J Prosthet Dent       Date:  2004-01       Impact factor: 3.426

Review 5.  Bone stress distribution for three endosseous implants.

Authors:  M R Rieger; K Fareed; W K Adams; R A Tanquist
Journal:  J Prosthet Dent       Date:  1989-02       Impact factor: 3.426

Review 6.  Effect of implant size and shape on implant success rates: a literature review.

Authors:  Jae-Hoon Lee; Val Frias; Keun-Woo Lee; Robert F Wright
Journal:  J Prosthet Dent       Date:  2005-10       Impact factor: 3.426

Review 7.  Osseointegration and its experimental background.

Authors:  P I Brånemark
Journal:  J Prosthet Dent       Date:  1983-09       Impact factor: 3.426

  7 in total
  4 in total

1.  Association between implant apex and sinus floor in posterior maxilla dental implantation: A three-dimensional finite element analysis.

Authors:  Xu Yan; Xinwen Zhang; Weichao Chi; Hongjun Ai; Lin Wu
Journal:  Exp Ther Med       Date:  2015-01-22       Impact factor: 2.447

2.  Effect of thread depth and implant shape on stress distribution in anterior and posterior regions of mandible bone: A finite element analysis.

Authors:  Falah A Hussein; Kareem N Salloomi; Besaran Y Abdulrahman; Abdulsalam R Al-Zahawi; Laith A Sabri
Journal:  Dent Res J (Isfahan)       Date:  2019 May-Jun

3.  Finite element analysis of stress concentration between surface coated implants and non surface coated implants - An in vitro study.

Authors:  Tammineedi Sv Satyanarayana; Rathika Rai; E Subramanyam; T Illango; Vishwabharathi Mutyala; Rajesh Akula
Journal:  J Clin Exp Dent       Date:  2019-08-01

4.  Study to assess the relationship between insertion torque value and implant stability quotient and its influence on timing of functional implant loading.

Authors:  Hasan Sarfaraz; Shefali Johri; P Sucheta; Sripathi Rao
Journal:  J Indian Prosthodont Soc       Date:  2018 Apr-Jun
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.