Literature DB >> 22940741

4-Liter split-dose polyethylene glycol is superior to other bowel preparations, based on systematic review and meta-analysis.

Brintha K Enestvedt1, Christina Tofani, Loren A Laine, Ann Tierney, M Brian Fennerty.   

Abstract

BACKGROUND & AIMS: Adequate bowel cleansing is an important determinant of the efficacy of screening colonoscopy. Polyethylene glycol (PEG)-based solutions are used commonly in bowel preparation, but their poor palatability and large volumes (4 L) influence compliance. Adjunct therapies, such as bisacodyl, split-dose regimens, and lower-volume regimens have been tested. We performed a meta-analysis to determine whether a 4-L split dose of PEG is better than others for bowel cleansing before colonoscopy.
METHODS: We searched MEDLINE, the Cochrane Central Register of Controlled Trials and Database, recent abstracts from major conference proceedings, references from selected reviews and randomized trials (http://clinicaltrials.gov), and Google Scholar, through September 2011, for high-quality, randomized trials that compared 4-L split-dose PEG without adjunct therapy with other bowel preparation methods. Nine of 2477 trials considered were used in the analysis. We calculated pooled estimates of bowel preparation quality (primary outcome: excellent or good), preparation compliance, favorable overall experiences, willingness to repeat same preparation, and side effects. We calculated pooled estimates of odds ratios by fixed- and random-effects models. We also assessed heterogeneity among studies and publication bias.
RESULTS: The overall pooled odds ratio for excellent or good bowel preparation quality for 4-L split-dose PEG was 3.46, compared with other methods (95% confidence interval, 2.45-4.89; P < .01). Although there was significant heterogeneity in results among studies, 7 of 9 reported a significant benefit from the 4-L split-dose PEG preparation. There were no significant differences between PEG and others in preparation compliance, favorable overall experience, willingness to repeat the same preparation, abdominal cramping, nausea, or sleep disturbance. There was no significant publication bias based on funnel plot.
CONCLUSIONS: A meta-analysis showed that 4-L split-dose PEG is better than other bowel preparation methods for colonoscopy. Significant heterogeneity among studies might result from differences in patient demographics and protocols. A 4-L split dose of PEG should be considered the standard with which new bowel preparation methods are compared.
Copyright © 2012 AGA Institute. Published by Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2012        PMID: 22940741     DOI: 10.1016/j.cgh.2012.08.029

Source DB:  PubMed          Journal:  Clin Gastroenterol Hepatol        ISSN: 1542-3565            Impact factor:   11.382


  61 in total

Review 1.  Colon cleansing for colonoscopy 2013: current status.

Authors:  Stephen W Landreneau; Jack A Di Palma
Journal:  Curr Gastroenterol Rep       Date:  2013-08

2.  Optimal Bowel Cleansing for Colonoscopy in the Elderly Patient.

Authors:  Samuel B Ho; Rita Hovsepians; Samir Gupta
Journal:  Drugs Aging       Date:  2017-03       Impact factor: 3.923

Review 3.  Update on Bowel Preparation for Colonoscopy.

Authors:  Cristina C Rutherford; Audrey H Calderwood
Journal:  Curr Treat Options Gastroenterol       Date:  2018-03

4.  Predictors of Inadequate Inpatient Colonoscopy Preparation and Its Association with Hospital Length of Stay and Costs.

Authors:  Rena Yadlapati; Elyse R Johnston; Dyanna L Gregory; Jody D Ciolino; Andrew Cooper; Rajesh N Keswani
Journal:  Dig Dis Sci       Date:  2015-06-21       Impact factor: 3.199

5.  Response to Gerard et al.

Authors:  Matthew L Bechtold; Sameer Siddique; Douglas L Nguyen
Journal:  Am J Gastroenterol       Date:  2015-02       Impact factor: 10.864

6.  Response to Syed.

Authors:  Matthew L Bechtold; Sameer Siddique; Douglas L Nguyen
Journal:  Am J Gastroenterol       Date:  2015-03       Impact factor: 10.864

7.  An Automated Inpatient Split-dose Bowel Preparation System Improves Colonoscopy Quality and Reduces Repeat Procedures.

Authors:  Rena Yadlapati; Elyse R Johnston; Adam B Gluskin; Dyanna L Gregory; Rachel Cyrus; Lindsay Werth; Jody D Ciolino; David P Grande; Rajesh N Keswani
Journal:  J Clin Gastroenterol       Date:  2018-09       Impact factor: 3.062

8.  Video on Diet Before Outpatient Colonoscopy Does Not Improve Quality of Bowel Preparation: A Prospective, Randomized, Controlled Trial.

Authors:  Sean C Rice; Tina Higginbotham; Melanie J Dean; James C Slaughter; Patrick S Yachimski; Keith L Obstein
Journal:  Am J Gastroenterol       Date:  2016-10-18       Impact factor: 10.864

9.  Same-day 2-L PEG-citrate-simethicone plus bisacodyl vs split 4-L PEG: Bowel cleansing for late-morning colonoscopy.

Authors:  Annalisa de Leone; Darina Tamayo; Giancarla Fiori; Davide Ravizza; Cristina Trovato; Giuseppe De Roberto; Linda Fazzini; Marco Dal Fante; Cristiano Crosta
Journal:  World J Gastrointest Endosc       Date:  2013-09-16

10.  Does 2 L Polyethylene Glycol Plus Ascorbic Acid Increase the Risk of Renal Impairment Compared to 4 L Polyethylene Glycol?

Authors:  Sang Pyo Lee; Eugene Park; Han Viet Kim; In-Kyung Sung; Jeong Hwan Kim; Sun-Young Lee; Hyung Seok Park; Chan Sup Shim
Journal:  Dig Dis Sci       Date:  2016-09-13       Impact factor: 3.199

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.