Literature DB >> 22926629

Flow diversion treatment: intra-aneurismal blood flow velocity and WSS reduction are parameters to predict aneurysm thrombosis.

Zsolt Kulcsár1, Luca Augsburger, Philippe Reymond, Vitor M Pereira, Sven Hirsch, Ajit S Mallik, John Millar, Stephan G Wetzel, Isabel Wanke, Daniel A Rüfenacht.   

Abstract

BACKGROUND: To evaluate the haemodynamic changes induced by flow diversion treatment in cerebral aneurysms, resulting in thrombosis or persisting aneurysm patency over time.
METHOD: Eight patients with aneurysms at the para-ophthalmic segment of the internal carotid artery were treated by flow diversion only. The clinical follow-up ranged between 6 days and 12 months. Computational fluid dynamics (CFD) analysis of pre- and post-treatment conditions was performed in all cases. True geometric models of the flow diverter were created and placed over the neck of the aneurysms by using a virtual stent-deployment technique, and the device was simulated as a true physical barrier. Pre- and post-treatment haemodynamics were compared, including mean and maximal velocities, wall-shear stress (WSS) and intra-aneurysmal flow patterns. The CFD study results were then correlated to angiographic follow-up studies.
RESULTS: Mean intra-aneurysmal flow velocities and WSS were significantly reduced in all aneurysms. Changes in flow patterns were recorded in only one case. Seven of eight aneurysms showed complete occlusion during the follow-up. One aneurysm remaining patent after 1 year showed no change in flow patterns. One aneurysm rupturing 5 days after treatment showed also no change in flow pattern, and no change in the maximal inflow velocity.
CONCLUSIONS: Relative flow velocity and WSS reduction in and of itself may result in aneurysm thrombosis in the majority of cases. Flow reductions under aneurysm-specific thresholds may, however, be the reason why some aneurysms remain completely or partially patent after flow diversion.

Entities:  

Mesh:

Year:  2012        PMID: 22926629     DOI: 10.1007/s00701-012-1482-2

Source DB:  PubMed          Journal:  Acta Neurochir (Wien)        ISSN: 0001-6268            Impact factor:   2.216


  33 in total

Review 1.  Flow-diverter devices in the treatment of intracranial aneurysms: A meta-analysis and systematic review.

Authors:  Xianli Lv; Hongchao Yang; Peng Liu; Youxiang Li
Journal:  Neuroradiol J       Date:  2016-02-02

2.  Correlating Hemodynamic Changes and Occlusion Time after Flow Diverter Treatment of Bilateral Large Internal Carotid Artery Aneurysms.

Authors:  A C-O Tsang; A Y-S Tang; W C Chung; G K-K Leung; K W Chow
Journal:  Clin Neuroradiol       Date:  2016-02-11       Impact factor: 3.649

Review 3.  Clinical Presentation, Imaging, and Management of Complications due to Neurointerventional Procedures.

Authors:  Matthew C Davis; John P Deveikis; Mark R Harrigan
Journal:  Semin Intervent Radiol       Date:  2015-06       Impact factor: 1.513

Review 4.  On Flow Diversion: The Changing Landscape of Intracerebral Aneurysm Management.

Authors:  A A Dmytriw; K Phan; J M Moore; V M Pereira; T Krings; A J Thomas
Journal:  AJNR Am J Neuroradiol       Date:  2019-03-20       Impact factor: 3.825

5.  Magnetic resonance imaging as a tool to assess reliability in simulating hemodynamics in cerebral aneurysms with a dedicated computational fluid dynamics prototype: preliminary results.

Authors:  Christof Karmonik; Y Jonathan Zhang; Orlando Diaz; Richard Klucznik; Sasan Partovi; Robert G Grossman; Gavin W Britz
Journal:  Cardiovasc Diagn Ther       Date:  2014-04

6.  Angiographic assessment of the efficacy of flow diverter treatment for cerebral aneurysms.

Authors:  Chander Sadasivan; Ronak Dholakia; Lissa Peeling; Philipp Gölitz; Arnd Doerfler; Baruch B Lieber; David J Fiorella; Henry H Woo
Journal:  Interv Neuroradiol       Date:  2019-07-11       Impact factor: 1.610

7.  In vitro, contrast agent-based evaluation of the influence of flow diverter size and position on intra-aneurysmal flow dynamics using syngo iFlow.

Authors:  Giorgio Franco Maria Cattaneo; Andreas Ding; Tobias Jost; Désirée Ley; Ruben Mühl-Bennighaus; Umut Yilmaz; Heiko Körner; Wolfgang Reith; Andreas Simgen
Journal:  Neuroradiology       Date:  2017-08-25       Impact factor: 2.804

8.  In vitro investigation of contrast flow jet timing in patient-specific intracranial aneurysms.

Authors:  Liang-der Jou; Virendra R Desai; Garvin W Britz
Journal:  Quant Imaging Med Surg       Date:  2016-04

9.  Virtual-versus-Real Implantation of Flow Diverters: Clinical Potential and Influence of Vascular Geometry.

Authors:  P Bouillot; O Brina; H Yilmaz; M Farhat; G Erceg; K-O Lovblad; M I Vargas; Z Kulcsar; V M Pereira
Journal:  AJNR Am J Neuroradiol       Date:  2016-06-30       Impact factor: 3.825

10.  Cerebral aneurysms treated with flow-diverting stents: computational models with intravascular blood flow measurements.

Authors:  M R Levitt; P M McGah; A Aliseda; P D Mourad; J D Nerva; S S Vaidya; R P Morton; B V Ghodke; L J Kim
Journal:  AJNR Am J Neuroradiol       Date:  2013-07-18       Impact factor: 3.825

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.