Literature DB >> 22920815

Determinants of the accuracy of continuous glucose monitoring in non-critically ill patients with heart failure or severe hyperglycemia.

Kathleen M Dungan1, Wen Han, Anthony Miele, Trisha Zeidan, Karen Weiland.   

Abstract

BACKGROUND: The accuracy of continuous glucose monitoring (CGM) in non-critically ill hospitalized patients with heart failure or severe hyperglycemia (SH) is unknown.
METHODS: Hospitalized patients with congestive heart failure (CHF) exacerbation (receiving IV or subcutaneous insulin) or SH requiring insulin infusion were compared to outpatients referred for retrospective CGM.
RESULTS: Forty-three patients with CHF, 15 patients with SH, and 88 outpatients yielded 470, 164, and 2150 meter-sensor pairs, respectively. Admission glucose differed (188 versus 509 mg/dl in CHF and SH, p < .001) but not the first sensor glucose (p = .35). In continuous glucose error grid analysis, 67-78% of pairs during hypoglycemia were in zones A+B (p = .63), compared with 98-100% in euglycemia (p < .001) and 98%, 92%, and 99% (p = .001) during hyperglycemia for the CHF, SH, and outpatient groups, respectively. Mean absolute relative difference (MARD) was lower in the CHF versus the SH group in glucose strata above 100 mg/dl, but there was no difference between the CHF and outpatient groups. Linear regression models showed that CHF versus outpatient, SH versus CHF, and coefficient of variation were significant predictors of higher MARD. Among subjects with CHF, MARD was not associated with brain natriuretic peptide or change in plasma volume, but it was significantly higher in subjects randomized to IV insulin (p = .04).
CONCLUSIONS: The results suggest that SH and glycemic variability are more important determinants of CGM accuracy than known CHF status alone in hospitalized patients.
© 2012 Diabetes Technology Society.

Entities:  

Mesh:

Substances:

Year:  2012        PMID: 22920815      PMCID: PMC3440160          DOI: 10.1177/193229681200600420

Source DB:  PubMed          Journal:  J Diabetes Sci Technol        ISSN: 1932-2968


  18 in total

1.  Evaluating the accuracy of continuous glucose-monitoring sensors: continuous glucose-error grid analysis illustrated by TheraSense Freestyle Navigator data.

Authors:  Boris P Kovatchev; Linda A Gonder-Frederick; Daniel J Cox; William L Clarke
Journal:  Diabetes Care       Date:  2004-08       Impact factor: 19.112

Review 2.  The original Clarke Error Grid Analysis (EGA).

Authors:  William L Clarke
Journal:  Diabetes Technol Ther       Date:  2005-10       Impact factor: 6.118

Review 3.  Glucose measurement: confounding issues in setting targets for inpatient management.

Authors:  Kathleen Dungan; John Chapman; Susan S Braithwaite; John Buse
Journal:  Diabetes Care       Date:  2007-02       Impact factor: 19.112

4.  Accuracy and reliability of a subcutaneous continuous glucose-monitoring system in critically ill patients.

Authors:  Richard Brunner; Reinhard Kitzberger; Wolfgang Miehsler; Harald Herkner; Christian Madl; Ulrike Holzinger
Journal:  Crit Care Med       Date:  2011-04       Impact factor: 7.598

5.  Real-time continuous glucose monitoring in pediatric patients during and after cardiac surgery.

Authors:  Hannah G Piper; Jamin L Alexander; Avinash Shukla; Frank Pigula; John M Costello; Peter C Laussen; Tom Jaksic; Michael S D Agus
Journal:  Pediatrics       Date:  2006-09       Impact factor: 7.124

Review 6.  Recent progress in analytical instrumentation for glycemic control in diabetic and critically ill patients.

Authors:  Venkata Radhakrishna Kondepati; H Michael Heise
Journal:  Anal Bioanal Chem       Date:  2007-03-13       Impact factor: 4.142

7.  Memoirs of a root canal salesman: the successful implementation of a hospital-wide intravenous insulin infusion protocol.

Authors:  Philip A Goldberg
Journal:  Endocr Pract       Date:  2006 Jul-Aug       Impact factor: 3.443

8.  Reliability of point-of-care testing for glucose measurement in critically ill adults.

Authors:  Salmaan Kanji; Jennifer Buffie; Brian Hutton; Peter S Bunting; Avinder Singh; Kevin McDonald; Dean Fergusson; Lauralyn A McIntyre; Paul C Hebert
Journal:  Crit Care Med       Date:  2005-12       Impact factor: 7.598

Review 9.  The regulation and measurement of plasma volume in heart failure.

Authors:  Paul R Kalra; Constantinos Anagnostopoulos; Aidan P Bolger; Andrew J S Coats; Stefan D Anker
Journal:  J Am Coll Cardiol       Date:  2002-06-19       Impact factor: 24.094

10.  Accuracy and feasibility of point-of-care and continuous blood glucose analysis in critically ill ICU patients.

Authors:  Anouk M Corstjens; Jack J M Ligtenberg; Iwan C C van der Horst; Rob Spanjersberg; Joline S W Lind; Jaap E Tulleken; John H J M Meertens; Jan G Zijlstra
Journal:  Crit Care       Date:  2006       Impact factor: 9.097

View more
  4 in total

1.  Consensus Statement on Inpatient Use of Continuous Glucose Monitoring.

Authors:  Amisha Wallia; Guillermo E Umpierrez; Robert J Rushakoff; David C Klonoff; Daniel J Rubin; Sherita Hill Golden; Curtiss B Cook; Bithika Thompson
Journal:  J Diabetes Sci Technol       Date:  2017-04-21

2.  The effect of congestive heart failure on sensor accuracy among hospitalized patients with type 2 diabetes.

Authors:  Kathleen Dungan; Kari Graessle; Colleen Sagrilla
Journal:  Diabetes Technol Ther       Date:  2013-10       Impact factor: 6.118

Review 3.  An Overview of Safety Issues on Use of Insulin Pumps and Continuous Glucose Monitoring Systems in the Hospital.

Authors:  Bithika Thompson; Melinda Leighton; Mary Korytkowski; Curtiss B Cook
Journal:  Curr Diab Rep       Date:  2018-08-17       Impact factor: 4.810

4.  Continuous Glucose Monitors and Automated Insulin Dosing Systems in the Hospital Consensus Guideline.

Authors:  Rodolfo J Galindo; Guillermo E Umpierrez; Robert J Rushakoff; Ananda Basu; Suzanne Lohnes; James H Nichols; Elias K Spanakis; Juan Espinoza; Nadine E Palermo; Dessa Garnett Awadjie; Leigh Bak; Bruce Buckingham; Curtiss B Cook; Guido Freckmann; Lutz Heinemann; Roman Hovorka; Nestoras Mathioudakis; Tonya Newman; David N O'Neal; Michaela Rickert; David B Sacks; Jane Jeffrie Seley; Amisha Wallia; Trisha Shang; Jennifer Y Zhang; Julia Han; David C Klonoff
Journal:  J Diabetes Sci Technol       Date:  2020-09-28
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.