Literature DB >> 19037643

Correctness of multi-detector-row computed tomography for diagnosing mechanical prosthetic heart valve disorders using operative findings as a gold standard.

I-Chen Tsai1, Yung-Kai Lin, Yen Chang, Yun-Ching Fu, Chung-Chi Wang, Shih-Rong Hsieh, Hao-Ji Wei, Hung-Wen Tsai, Sheng-Ling Jan, Kuo-Yang Wang, Min-Chi Chen, Clayton Chi-Chang Chen.   

Abstract

The purpose was to compare the findings of multi-detector computed tomography (MDCT) in prosthetic valve disorders using the operative findings as a gold standard. In a 3-year period, we prospectively enrolled 25 patients with 31 prosthetic heart valves. MDCT and transthoracic echocardiography (TTE) were done to evaluate pannus formation, prosthetic valve dysfunction, suture loosening (paravalvular leak) and pseudoaneurysm formation. Patients indicated for surgery received an operation within 1 week. The MDCT findings were compared with the operative findings. One patient with a Björk-Shiley valve could not be evaluated by MDCT due to a severe beam-hardening artifact; thus, the exclusion rate for MDCT was 3.2% (1/31). Prosthetic valve disorders were suspected in 12 patients by either MDCT or TTE. Six patients received an operation that included three redo aortic valve replacements, two redo mitral replacements and one Amplatzer ductal occluder occlusion of a mitral paravalvular leak. The concordance of MDCT for diagnosing and localizing prosthetic valve disorders and the surgical findings was 100%. Except for images impaired by severe beam-hardening artifacts, MDCT provides excellent delineation of prosthetic valve disorders.

Entities:  

Mesh:

Year:  2008        PMID: 19037643     DOI: 10.1007/s00330-008-1232-2

Source DB:  PubMed          Journal:  Eur Radiol        ISSN: 0938-7994            Impact factor:   5.315


  22 in total

1.  Detection of pannus by multidetector-row computed tomography.

Authors:  Hideki Teshima; Nobuhiko Hayashida; Naofumi Enomoto; Shigeaki Aoyagi; Koji Okuda; Masafumi Uchida
Journal:  Ann Thorac Surg       Date:  2003-05       Impact factor: 4.330

2.  Usefulness of ECG-gated multi-detector computed tomography for the diagnosis of mechanical prosthetic valve dysfunction.

Authors:  Laurent Leborgne; Cédric Renard; Christophe Tribouilloy
Journal:  Eur Heart J       Date:  2006-04-13       Impact factor: 29.983

3.  Blockage of bileaflet mitral valve prosthesis imaged by computed tomography virtual endoscopy.

Authors:  F F Faletra; M Alain; T Moccetti
Journal:  Heart       Date:  2007-03       Impact factor: 5.994

4.  MDCT evaluation after closure of atrial septal defect with an Amplatzer septal occluder.

Authors:  Tain Lee; I-Chen Tsai; Yun-Ching Fu; Sheng-Lin Jan; Chung-Chi Wang; Yen Chang; Min-Chi Chen
Journal:  AJR Am J Roentgenol       Date:  2007-05       Impact factor: 3.959

Review 5.  Valve disease: Surgery of valve disease: late results and late complications.

Authors:  P Groves
Journal:  Heart       Date:  2001-12       Impact factor: 5.994

6.  Three-dimensional imaging of fractures in outlet struts of Björk-Shiley convexo-concave heart valves by microcomputed tomography in vitro.

Authors:  Avrom M Brendzel; Edmond Rambod; Steven M Jorgensen; Denise A Reyes; Michael S Chmelik; Erik L Ritman
Journal:  J Heart Valve Dis       Date:  2002-01

7.  Homogeneous enhancement in pediatric thoracic CT aortography using a novel and reproducible method: contrast-covering time.

Authors:  I-Chen Tsai; Tain Lee; Min-Chi Chen; Wei-Lin Tsai; Pao-Chun Lin; Wan-Chun Liao
Journal:  AJR Am J Roentgenol       Date:  2007-04       Impact factor: 3.959

8.  Using multidetector-row CT in neonates with complex congenital heart disease to replace diagnostic cardiac catheterization for anatomical investigation: initial experiences in technical and clinical feasibility.

Authors:  Tain Lee; I-Chen Tsai; Yun-Ching Fu; Sheng-Lin Jan; Chung-Chi Wang; Yen Chang; Min-Chi Chen
Journal:  Pediatr Radiol       Date:  2006-10-12

9.  Long-term relative survival rates after heart valve replacement.

Authors:  D Lindblom; U Lindblom; J Qvist; H Lundström
Journal:  J Am Coll Cardiol       Date:  1990-03-01       Impact factor: 24.094

Review 10.  Neonatal cardiac multidetector row CT: why and how we do it.

Authors:  I-Chen Tsai; Min-Chi Chen; Sheng-Ling Jan; Chung-Chi Wang; Yun-Ching Fu; Pao-Chun Lin; Tain Lee
Journal:  Pediatr Radiol       Date:  2008-02-08
View more
  30 in total

1.  ECG-gated computed tomography: a new role for patients with suspected aortic prosthetic valve endocarditis.

Authors:  Erika Fagman; Sossio Perrotta; Odd Bech-Hanssen; Agneta Flinck; Carl Lamm; Lars Olaison; Gunnar Svensson
Journal:  Eur Radiol       Date:  2012-05-24       Impact factor: 5.315

2.  Dual-step prospective ECG-triggered 128-slice dual-source CT for evaluation of coronary arteries and cardiac function without heart rate control: a technical note.

Authors:  Gudrun Feuchtner; Robert Goetti; Andrè Plass; Stephan Baumueller; Paul Stolzmann; Hans Scheffel; Monika Wieser; Borut Marincek; Hatem Alkadhi; Sebastian Leschka
Journal:  Eur Radiol       Date:  2010-04-21       Impact factor: 5.315

3.  Factors affecting computed tomography image quality for assessment of mechanical aortic valves.

Authors:  Young Joo Suh; Young Jin Kim; Yoo Jin Hong; Hye-Jeong Lee; Jin Hur; Sae Rom Hong; Dong Jin Im; Yun Jung Kim; Byoung Wook Choi
Journal:  Int J Cardiovasc Imaging       Date:  2015-12-01       Impact factor: 2.357

4.  The utility of computed tomography in the context of aortic valve disease.

Authors:  Gudrun M Feuchtner
Journal:  Int J Cardiovasc Imaging       Date:  2009-05-26       Impact factor: 2.357

5.  Resolution of thrombus in left ventricular outflow tract pseudoaneurysm mimicking periaortic abscess.

Authors:  Levent Korkmaz; Abdulkadir Kiris; Mustafa Tarik Agac; Zeydin Acar; Ayca Ata Korkmaz; Selim Kul; Devrim Kurt; Sukru Celik
Journal:  J Cardiol Cases       Date:  2010-06-30

6.  ASCI 2010 appropriateness criteria for cardiac computed tomography: a report of the Asian Society of Cardiovascular Imaging Cardiac Computed Tomography and Cardiac Magnetic Resonance Imaging Guideline Working Group.

Authors:  I-Chen Tsai; Byoung Wook Choi; Carmen Chan; Masahiro Jinzaki; Kakuya Kitagawa; Hwan Seok Yong; Wei Yu
Journal:  Int J Cardiovasc Imaging       Date:  2010-01-22       Impact factor: 2.357

7.  Letter to the Editor re: Correctness of multi-detector-row computed tomography for diagnosing mechanical prosthetic heart valve disorders using operative findings as a gold standard.

Authors:  Mehmet Özkan; Sabahattin Gündüz; Murat Biteker; Nilüfer Ekşi Duran; Tahsin Güneysu
Journal:  Eur Radiol       Date:  2009-12       Impact factor: 5.315

8.  Organized prosthetic tricuspid valve thrombosis treated successfully with medical treatment.

Authors:  Hyo-Sun Shin; Kyung-Hee Kim; Hee-Sun Lee; Hong-Mi Choi; Seung-Ah Lee; Eun-Ah Park; Hyung-Kwan Kim
Journal:  J Cardiovasc Ultrasound       Date:  2013-12-27

9.  Recommendations on nuclear and multimodality imaging in IE and CIED infections.

Authors:  Paola Anna Erba; Patrizio Lancellotti; Isidre Vilacosta; Oliver Gaemperli; Francois Rouzet; Marcus Hacker; Alberto Signore; Riemer H J A Slart; Gilbert Habib
Journal:  Eur J Nucl Med Mol Imaging       Date:  2018-05-24       Impact factor: 9.236

10.  Assessment of a transcatheter heart valve prosthesis with multidetector computed tomography: in vitro and in vivo imaging characteristics.

Authors:  Linda M de Heer; Jesse Habets; Jolanda Kluin; Pieter R Stella; Willem P Th M Mali; Lex A van Herwerden; Ricardo P J Budde
Journal:  Int J Cardiovasc Imaging       Date:  2012-08-09       Impact factor: 2.357

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.