AIM: To verify the usefulness of a sliding scale of imaging parameters to reduce radiation exposure during chest interventional radiology (IR), and to identify factors that increase radiation exposure in order to obtain acceptable computed tomography (CT)-fluoroscopy image quality.
MATERIALS AND METHODS: The institutional review board approved this retrospective study, for which the need for informed consent was waived. Interventional radiologists determined the optimal CT-fluoroscopy imaging parameters using the sliding scale based on the radiation exposure dose. The imaging parameters were changed from those generating low radiation (120 kV/10 mA, 1.2 mGy/s) to others generating higher radiation exposure until acceptable image quality was obtained for each procedure. Validation of the imaging parameter sliding scale was done using regression analysis. Factors that increase radiation exposure were identified using multiple regression analysis.
RESULTS: In 125 patients, 217 procedures were performed, of which 72 procedures (33.2%, 72/217) were performed with imaging parameters of minimum radiation exposure, but increased radiation exposure was necessary in 145 (66.8%, 145/217). Significant correlation was found between the radiation exposure dose and the percentage achievement of acceptable image quality (R(2) = 0.98). Multivariate regression analysis showed that high body weight (p < 0.0001), long device passage (p < 0.0001), and lesions above the aortic arch (p = 0.04) were significant independent factors increasing radiation exposure.
CONCLUSION: Although increased radiation exposure dose might be necessary to obtain acceptable chest CT-fluoroscopy images depending on the patient, lesion, and procedure characteristics, a sliding scale of imaging parameters helps to reduce radiation exposure.
Copyright © 2012 The Royal College of Radiologists. Published by Elsevier Ltd. All rights reserved.

Entities:  

Mesh:

Year:  2012        PMID: 22906574     DOI: 10.1016/j.crad.2012.05.020

Source DB:  PubMed          Journal:  Clin Radiol        ISSN: 0009-9260            Impact factor:   2.350


  3 in total

1.  Radiation Eye Dose for Physicians in CT Fluoroscopy-Guided Biopsy.

Authors:  Yohei Inaba; Shin Hitachi; Munenori Watanuki; Koichi Chida
Journal:  Tomography       Date:  2022-02-08

2.  Evaluation of an X-Ray Dose Profile Derived from an Optically Stimulated Luminescent Dosimeter during Computed Tomographic Fluoroscopy.

Authors:  Hiroaki Hasegawa; Masanori Sato; Hiroshi Tanaka
Journal:  PLoS One       Date:  2015-07-07       Impact factor: 3.240

3.  Influences of cardiac motion on computed tomography-guided biopsy of lung nodules located near the heart.

Authors:  Li-Sheng Hsu; Chien-Wei Chen; Chia-Hao Chang; Chien-Han Liao; Sheng-Lung Hsu; Wei-Ming Lin
Journal:  Medicine (Baltimore)       Date:  2017-11       Impact factor: 1.889

  3 in total