Endoscopic Functional Fourier Domain Common Path Optical Coherence Tomography for Microsurgery.

Jin U Kang1, Jae-Ho Han, Xuan Liu, Kang Zhang, Chul Gyu Song, Peter Gehlbach.   

Abstract

A single-arm interferometer based optical coherence tomography (OCT) system known as common-path OCT (CPOCT) is rapidly progressing towards practical application. Due in part to the simplicity and robustness of its design, Fourier Domain CPOCT (FD-CP-OCT) offers advantages in many endoscopic sensing and imaging applications. FD-CP-OCT uses simple, interchangeable fiber optic probes that are easily integrated into small and delicate surgical tools. The system is capable of providing not only high resolution imaging but also optical sensing. Here, we report progress towards practical application of FD-CP-OCT in the setting of delicate microsurgical procedures such as intraocular retinal surgery. To meet the challenges presented by the microsurgical requirements of these procedures, we have developed and initiated the validation of applicable fiber optic probes. By integrating these probes into our developing imaging system, we have obtained high resolution OCT images and have also completed a demonstration of their potential sensing capabilities. Specifically, we utilize multiple SLEDs to demonstrate sub 3-micron axial resolution in water; we propose a technique to quantitatively evaluate the spatial distribution of oxygen saturation levels in tissue; and we present evidence supportive of the technology's surface sensing and tool guidance potential by demonstrating topological and motion compensation capabilities.

Entities:  

Year:  2010        PMID: 22899880      PMCID: PMC3418670          DOI: 10.1109/jstqe.2009.2031597

Source DB:  PubMed          Journal:  IEEE J Sel Top Quantum Electron        ISSN: 1077-260X            Impact factor:   4.544


  46 in total

1.  Common-path optical coherence tomography with side-viewing bare fiber probe for endoscopic optical coherence tomography.

Authors:  Utkarsh Sharma; Jin U Kang
Journal:  Rev Sci Instrum       Date:  2007-11       Impact factor: 1.523

2.  Performance of fourier domain vs. time domain optical coherence tomography.

Authors:  R Leitgeb; C Hitzenberger; Adolf Fercher
Journal:  Opt Express       Date:  2003-04-21       Impact factor: 3.894

3.  Ultrahigh resolution optical coherence tomography imaging with a broadband superluminescent diode light source.

Authors:  Tony Ko; Desmond Adler; James Fujimoto; Dmitry Mamedov; Viatcheslav Prokhorov; Vladimir Shidlovski; Sergei Yakubovich
Journal:  Opt Express       Date:  2004-05-17       Impact factor: 3.894

4.  Ultrahigh-resolution high-speed retinal imaging using spectral-domain optical coherence tomography.

Authors:  Barry Cense; Nader Nassif; Teresa Chen; Mark Pierce; Seok-Hyun Yun; B Park; Brett Bouma; Guillermo Tearney; Johannes de Boer
Journal:  Opt Express       Date:  2004-05-31       Impact factor: 3.894

Review 5.  Optical coherence tomography and cataract surgery.

Authors:  Stephen J Kim; Neil M Bressler
Journal:  Curr Opin Ophthalmol       Date:  2009-01       Impact factor: 3.761

6.  In-fiber common-path optical coherence tomography using a conical-tip fiber.

Authors:  K M Tan; M Mazilu; T H Chow; W M Lee; K Taguichi; B K Ng; W Sibbett; C S Herrington; C T A Brown; K Dholakia
Journal:  Opt Express       Date:  2009-02-16       Impact factor: 3.894

7.  Signal-to-noise ratio analysis of all-fiber common-path optical coherence tomography.

Authors:  Xiaolu Li; Jae-Ho Han; Xuan Liu; Jin U Kang
Journal:  Appl Opt       Date:  2008-09-20       Impact factor: 1.980

8.  Eye-length measurement by interferometry with partially coherent light.

Authors:  A F Fercher; K Mengedoht; W Werner
Journal:  Opt Lett       Date:  1988-03-01       Impact factor: 3.776

9.  In vivo endoscopic optical coherence tomography of esophagitis, Barrett's esophagus, and adenocarcinoma of the esophagus.

Authors:  S Jäckle; N Gladkova; F Feldchtein; A Terentieva; B Brand; G Gelikonov; V Gelikonov; A Sergeev; A Fritscher-Ravens; J Freund; U Seitz; S Schröder; N Soehendra
Journal:  Endoscopy       Date:  2000-10       Impact factor: 10.093

10.  Assessment of dermal wound repair after collagen implantation with optical coherence tomography.

Authors:  Zhenguo Wang; Hui Pan; Zhijia Yuan; Jingxuan Liu; Weiliam Chen; Yingtian Pan
Journal:  Tissue Eng Part C Methods       Date:  2008-03       Impact factor: 3.056

View more
  23 in total

1.  Miniature fiber-optic force sensor for vitreoretinal microsurgery based on low-coherence Fabry-Pérot interferometry.

Authors:  Xuan Liu; Iulian I Iordachita; Xingchi He; Russell H Taylor; Jin U Kang
Journal:  Proc SPIE Int Soc Opt Eng       Date:  2013-01-21

2.  Optimization of an angled fiber probe for common-path optical coherence tomography.

Authors:  Xuan Liu; Jin U Kang
Journal:  Opt Lett       Date:  2013-08-01       Impact factor: 3.776

3.  Development and preliminary results of bimanual smart micro-surgical system using a ball-lens coupled OCT distance sensor.

Authors:  Dongwoo Koo; Hyun-Cheol Park; Peter L Gehlbach; Cheol Song
Journal:  Biomed Opt Express       Date:  2016-10-31       Impact factor: 3.732

4.  Temporally and spatially adaptive Doppler analysis for robust handheld optical coherence elastography.

Authors:  Xuan Liu; Farzana R Zaki; Haokun Wu; Chizhong Wang; Yahui Wang
Journal:  Biomed Opt Express       Date:  2018-06-26       Impact factor: 3.732

5.  Active tremor cancellation by a "smart" handheld vitreoretinal microsurgical tool using swept source optical coherence tomography.

Authors:  Cheol Song; Peter L Gehlbach; Jin U Kang
Journal:  Opt Express       Date:  2012-10-08       Impact factor: 3.894

6.  Real-time three-dimensional Fourier-domain optical coherence tomography video image guided microsurgeries.

Authors:  Jin U Kang; Yong Huang; Kang Zhang; Zuhaib Ibrahim; Jaepyeong Cha; W P Andrew Lee; Gerald Brandacher; Peter L Gehlbach
Journal:  J Biomed Opt       Date:  2012-08       Impact factor: 3.170

7.  Improvement of optical coherence tomography using active handheld micromanipulator in vitreoretinal surgery.

Authors:  Sungwook Yang; Marcin Balicki; Trent S Wells; Robert A Maclachlan; Xuan Liu; Jin U Kang; James T Handa; Russell H Taylor; Cameron N Riviere
Journal:  Conf Proc IEEE Eng Med Biol Soc       Date:  2013

8.  Ultrathin lensed fiber-optic probe for optical coherence tomography.

Authors:  Y Qiu; Y Wang; K D Belfield; X Liu
Journal:  Biomed Opt Express       Date:  2016-05-10       Impact factor: 3.732

9.  Sparse OCT: Optimizing compressed sensing in spectral domain optical coherence tomography.

Authors:  Xuan Liu; Jin U Kang
Journal:  Proc SPIE Int Soc Opt Eng       Date:  2011-02-10

10.  Sapphire ball lens-based fiber probe for common-path optical coherence tomography and its applications in corneal and retinal imaging.

Authors:  Mingtao Zhao; Yong Huang; Jin U Kang
Journal:  Opt Lett       Date:  2012-12-01       Impact factor: 3.776

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.