Literature DB >> 18806839

Signal-to-noise ratio analysis of all-fiber common-path optical coherence tomography.

Xiaolu Li1, Jae-Ho Han, Xuan Liu, Jin U Kang.   

Abstract

We present theoretical analysis and experimental verification of the signal to noise ratio (SNR) of a common-path interferometer-based optical coherence tomography (OCT) system. Based on fully integrated all-fiber implementation of a common-path time-domain OCT system, we derived the SNR of the system including the effect of beat noise, which turns out to be twice as large as the excess noise term. We verified the theoretical SNR through a series of experiments, utilizing both controlled phantom and biological samples such as a rat brain with tumor and a frog retina. The results showed that the source power and the reference reflectivity can be easily controlled to optimize the SNR of OCT imaging. We have also analyzed the effect of the fiber delays and the offset in the fiber autocorrelator of the common-path OCT system on the overall SNR.

Entities:  

Mesh:

Year:  2008        PMID: 18806839     DOI: 10.1364/ao.47.004833

Source DB:  PubMed          Journal:  Appl Opt        ISSN: 1559-128X            Impact factor:   1.980


  9 in total

1.  Common-path phase-sensitive optical coherence tomography provides enhanced phase stability and detection sensitivity for dynamic elastography.

Authors:  Gongpu Lan; Manmohan Singh; Kirill V Larin; Michael D Twa
Journal:  Biomed Opt Express       Date:  2017-10-26       Impact factor: 3.732

2.  Sapphire ball lensed fiber probe for common-path optical coherence tomography in ocular imaging and sensing.

Authors:  Mingtao Zhao; Yong Huang; Jin U Kang
Journal:  Proc SPIE Int Soc Opt Eng       Date:  2013-03-26

3.  Endoscopic Functional Fourier Domain Common Path Optical Coherence Tomography for Microsurgery.

Authors:  Jin U Kang; Jae-Ho Han; Xuan Liu; Kang Zhang; Chul Gyu Song; Peter Gehlbach
Journal:  IEEE J Sel Top Quantum Electron       Date:  2010-07       Impact factor: 4.544

4.  Common-Path Optical Coherence Tomography for Biomedical Imaging and Sensing.

Authors:  Jin U Kang; Jae-Ho Han; Xuan Liu; Kang Zhang
Journal:  J Opt Soc Korea       Date:  2010-03

5.  Investigation of gold-coated bare fiber probe for in situ intra-vitreous coherence domain optical imaging and sensing.

Authors:  J-H Han; I K Ilev; D-H Kim; C G Song; J U Kang
Journal:  Appl Phys B       Date:  2010-06-01       Impact factor: 2.070

6.  Polarization sensitive subcutaneous and muscular imaging based on common path optical coherence tomography using near infrared source.

Authors:  Jae-Ho Han; Jin U Kang; Chul Gyu Song
Journal:  J Med Syst       Date:  2009-11-24       Impact factor: 4.460

7.  A surface topology and motion compensation system for microsurgery guidance and intervention based on common-path optical coherence tomography.

Authors:  Kang Zhang; Weichao Wang; Jaeho Han; Jin U Kang
Journal:  IEEE Trans Biomed Eng       Date:  2009-06-02       Impact factor: 4.538

8.  Assessment and removal of additive noise in a complex optical coherence tomography signal based on Doppler variation analysis.

Authors:  Xuan Liu; Farzana Zaki; Dylan Renaud
Journal:  Appl Opt       Date:  2018-04-10       Impact factor: 1.980

9.  Towards automatic calibration of Fourier-Domain OCT for robot-assisted vitreoretinal surgery.

Authors:  Xuan Liu; Marcin Balicki; Russell H Taylor; Jin U Kang
Journal:  Opt Express       Date:  2010-11-08       Impact factor: 3.894

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.