Literature DB >> 18052460

Common-path optical coherence tomography with side-viewing bare fiber probe for endoscopic optical coherence tomography.

Utkarsh Sharma1, Jin U Kang.   

Abstract

All-fiber-optic common-path optical coherence tomography (OCT) using a side-viewing bare fiber probe has been demonstrated and analyzed. A bare single mode fiber tip is angle cleaved at approximately 49 degrees to enable side illumination due to total internal reflection. The bare fiber probe was inserted in an arterial tissue and a circumferential OCT scan was obtained. The research is aimed at realizing highly miniaturized monolithic probes for possible applications in miniature endoscopic OCT or intravascular OCT. The effects of the angle of the cleaved fiber on reference reflection and the sensitivity of the common-path OCT system have been studied theoretically. The angle cleaved fiber probe is also used in series with a microlens to analyze and optimize its performance in a common-path OCT system. Our research aims to explore the combined advantages of common-path OCT and extremely simplified miniature probe design and to discuss how it may greatly simplify the endoscopic OCT instrumentation eventually.

Mesh:

Year:  2007        PMID: 18052460     DOI: 10.1063/1.2804112

Source DB:  PubMed          Journal:  Rev Sci Instrum        ISSN: 0034-6748            Impact factor:   1.523


  13 in total

1.  Common-path low-coherence interferometry fiber-optic sensor guided microincision.

Authors:  Kang Zhang; Jin U Kang
Journal:  J Biomed Opt       Date:  2011-09       Impact factor: 3.170

2.  Miniature forward-viewing common-path OCT probe for imaging the renal pelvis.

Authors:  Xiaoyong Fu; Dhruti Patel; Hui Zhu; Gregory MacLennan; Yves T Wang; Michael W Jenkins; Andrew M Rollins
Journal:  Biomed Opt Express       Date:  2015-03-06       Impact factor: 3.732

3.  Ultra-thin and flexible endoscopy probe for optical coherence tomography based on stepwise transitional core fiber.

Authors:  Jangbeom Lee; Yugyeong Chae; Yeh-Chan Ahn; Sucbei Moon
Journal:  Biomed Opt Express       Date:  2015-04-21       Impact factor: 3.732

4.  Endoscopic optical coherence tomography: technologies and clinical applications [Invited].

Authors:  Michalina J Gora; Melissa J Suter; Guillermo J Tearney; Xingde Li
Journal:  Biomed Opt Express       Date:  2017-04-07       Impact factor: 3.732

5.  Common-path phase-sensitive optical coherence tomography provides enhanced phase stability and detection sensitivity for dynamic elastography.

Authors:  Gongpu Lan; Manmohan Singh; Kirill V Larin; Michael D Twa
Journal:  Biomed Opt Express       Date:  2017-10-26       Impact factor: 3.732

6.  Endoscopic Functional Fourier Domain Common Path Optical Coherence Tomography for Microsurgery.

Authors:  Jin U Kang; Jae-Ho Han; Xuan Liu; Kang Zhang; Chul Gyu Song; Peter Gehlbach
Journal:  IEEE J Sel Top Quantum Electron       Date:  2010-07       Impact factor: 4.544

7.  Common-Path Optical Coherence Tomography for Biomedical Imaging and Sensing.

Authors:  Jin U Kang; Jae-Ho Han; Xuan Liu; Kang Zhang
Journal:  J Opt Soc Korea       Date:  2010-03

8.  Investigation of gold-coated bare fiber probe for in situ intra-vitreous coherence domain optical imaging and sensing.

Authors:  J-H Han; I K Ilev; D-H Kim; C G Song; J U Kang
Journal:  Appl Phys B       Date:  2010-06-01       Impact factor: 2.070

9.  Real-time 4D signal processing and visualization using graphics processing unit on a regular nonlinear-k Fourier-domain OCT system.

Authors:  Kang Zhang; Jin U Kang
Journal:  Opt Express       Date:  2010-05-24       Impact factor: 3.894

10.  Mode-filtered large-core fiber for optical coherence tomography.

Authors:  Sucbei Moon; Zhongping Chen
Journal:  Appl Opt       Date:  2012-12-01       Impact factor: 1.980

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.