Performance assessment of an opto-fluidic phantom mimicking porcine liver parenchyma.

Tony J Akl1, Travis J King, Ruiqi Long, Michael J McShane, M Nance Ericson, Mark A Wilson, Gerard L Coté.   

Abstract

An implantable, optical oxygenation and perfusion sensor to monitor liver transplants during the two-week period following the transplant procedure is currently being developed. In order to minimize the number of animal experiments required for this research, a phantom that mimics the optical, anatomical, and physiologic flow properties of liver parenchyma is being developed as well. In this work, the suitability of this phantom for liver parenchyma perfusion research was evaluated by direct comparison of phantom perfusion data with data collected from in vivo porcine studies, both using the same prototype perfusion sensor. In vitro perfusion and occlusion experiments were performed on a single-layer and on a three-layer phantom perfused with a dye solution possessing the absorption properties of oxygenated hemoglobin. While both phantoms exhibited response patterns similar to the liver parenchyma, the signal measured from the multilayer phantom was three times higher than the single layer phantom and approximately 21 percent more sensitive to in vitro changes in perfusion. Although the multilayer phantom replicated the in vivo flow patterns more closely, the data suggests that both phantoms can be used in vitro to facilitate sensor design.

Entities:  

Mesh:

Year:  2012        PMID: 22894521      PMCID: PMC3394684          DOI: 10.1117/1.JBO.17.7.077008

Source DB:  PubMed          Journal:  J Biomed Opt        ISSN: 1083-3668            Impact factor:   3.170


  21 in total

1.  Validation of real-time continuous perfusion measurement.

Authors:  G T Martin; H F Bowman
Journal:  Med Biol Eng Comput       Date:  2000-05       Impact factor: 2.602

2.  Continuous monitoring of regional cerebral blood flow: experimental and clinical validation of a novel thermal diffusion microprobe.

Authors:  P Vajkoczy; H Roth; P Horn; T Lucke; C Thomé; U Hubner; G T Martin; C Zappletal; E Klar; L Schilling; P Schmiedek
Journal:  J Neurosurg       Date:  2000-08       Impact factor: 5.115

3.  An autocorrelation-based time domain analysis technique for monitoring perfusion and oxygenation in transplanted organs.

Authors:  Hariharan Subramanian; Bennett L Ibey; Weijian Xu; Mark A Wilson; M Nance Ericson; Gerard L Coté
Journal:  IEEE Trans Biomed Eng       Date:  2005-07       Impact factor: 4.538

4.  Implantable sensor for blood flow monitoring after transplant surgery.

Authors: 
Journal:  Minim Invasive Ther Allied Technol       Date:  2004-04       Impact factor: 2.442

5.  Echo-Doppler measurements of portal vein and hepatic artery in asymptomatic patients with hepatitis B virus and healthy adults.

Authors:  Christina Tziafalia; Marianna Vlychou; Konstantinos Tepetes; Nikolaos Kelekis; Ioannis V Fezoulidis
Journal:  J Gastrointestin Liver Dis       Date:  2006-12       Impact factor: 2.008

6.  Diffuse optical monitoring of hemodynamic changes in piglet brain with closed head injury.

Authors:  Chao Zhou; Stephanie A Eucker; Turgut Durduran; Guoqiang Yu; Jill Ralston; Stuart H Friess; Rebecca N Ichord; Susan S Margulies; Arjun G Yodh
Journal:  J Biomed Opt       Date:  2009 May-Jun       Impact factor: 3.170

7.  Thermal diffusion probe analysis of perfusion changes in vascular occlusions of rabbit pedicle flaps.

Authors:  Monica B Khot; Peter K M Maitz; Benjamin R Phillips; H Friederick Bowman; Julian J Pribaz; Dennis P Orgill
Journal:  Plast Reconstr Surg       Date:  2005-04       Impact factor: 4.730

8.  Effect of liver blood flow and function on hepatic indocyanine green clearance measured directly in a cirrhotic animal model.

Authors:  L R Jiao; A A El-Desoky; A M Seifalian; N Habib; B R Davidson
Journal:  Br J Surg       Date:  2000-05       Impact factor: 6.939

9.  Optofluidic phantom mimicking optical properties of porcine livers.

Authors:  Ruiqi Long; Travis King; Tony Akl; M Nance Ericson; Mark Wilson; Gerard L Coté; Michael J McShane
Journal:  Biomed Opt Express       Date:  2011-06-09       Impact factor: 3.732

Review 10.  Laser Doppler perfusion monitoring and imaging: novel approaches.

Authors:  Anne Humeau; Wiendelt Steenbergen; Henrik Nilsson; Tomas Strömberg
Journal:  Med Biol Eng Comput       Date:  2007-03-06       Impact factor: 3.079

View more
  3 in total

1.  Intestinal perfusion monitoring using photoplethysmography.

Authors:  Tony J Akl; Mark A Wilson; M Nance Ericson; Gerard L Coté
Journal:  J Biomed Opt       Date:  2013-08       Impact factor: 3.170

2.  Quantifying tissue mechanical properties using photoplethysmography.

Authors:  Tony J Akl; Mark A Wilson; M Nance Ericson; Gerard L Coté
Journal:  Biomed Opt Express       Date:  2014-06-19       Impact factor: 3.732

3.  Wireless monitoring of liver hemodynamics in vivo.

Authors:  Tony J Akl; Mark A Wilson; M Nance Ericson; Ethan Farquhar; Gerard L Coté
Journal:  PLoS One       Date:  2014-07-14       Impact factor: 3.240

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.