Literature DB >> 10912349

Validation of real-time continuous perfusion measurement.

G T Martin1, H F Bowman.   

Abstract

Perfusion, the rate at which blood in tissue is replenished at the capillary level, is a primary factor in the transport of heat, drugs, oxygen and nutrients. While there have been many measurement techniques proposed, most do not lend themselves to routine, continuous and real-time use. A minimally invasive probe, called the thermal diffusion probe (TDP), which uses a self-heated thermistor to measure absolute perfusion continuously and in real time, was validated at low flows with the microsphere technique. In 27 rabbits, simultaneous TDP measurements were made in liver from 0 to 60 ml min-1 100 g-1. The TDP perfusion correlated well with the microspheres (R2 = 0.898) and the agreement between techniques is very good with a slope close to unity (0.921) and an intercept close to zero (0.566 ml min-1 100 g-1). Variability between the two techniques was primarily due to the sampling error from the microsphere 'snap shot' of periodic blood flow when compared with the continuous TDP perfusion measurement. The ability to quantify local perfusion continuously and in real time may have a profound impact on patient management in a number of clinical areas such as organ transplantation, neurosurgery, oncology and others, in which quantitative knowledge of perfusion is of value.

Entities:  

Mesh:

Year:  2000        PMID: 10912349     DOI: 10.1007/bf02347053

Source DB:  PubMed          Journal:  Med Biol Eng Comput        ISSN: 0140-0118            Impact factor:   2.602


  12 in total

1.  Methodological error and spatial variability of organ blood flow measurements using radiolabeled microspheres.

Authors:  B Zwissler; R Schosser; C Weiss; V Iber; M Weiss; C Schwickert; P Spengler; K Messmer
Journal:  Res Exp Med (Berl)       Date:  1991

2.  Analysis of tissue and arterial blood temperatures in the resting human forearm.

Authors:  H H PENNES
Journal:  J Appl Physiol       Date:  1948-08       Impact factor: 3.531

Review 3.  Tumour blood flow: measurement and manipulation for therapeutic gain.

Authors:  S M Sagar; G A Klassen; K D Barclay; J E Aldrich
Journal:  Cancer Treat Rev       Date:  1993-10       Impact factor: 12.111

4.  Early assessment of reperfusion injury by intraoperative quantification of hepatic microcirculation in patients.

Authors:  E Klar; M Bredt; T Kraus; M Angelescu; A Mehrabi; N Senninger; G Otto; C Herfarth
Journal:  Transplant Proc       Date:  1997 Feb-Mar       Impact factor: 1.066

5.  Evaluation of laser-Doppler flowmetry as a measure of tissue blood flow.

Authors:  G J Smits; R J Roman; J H Lombard
Journal:  J Appl Physiol (1985)       Date:  1986-08

6.  The simultaneous measurement of thermal conductivity, thermal diffusivity, and perfusion in small volumes of tissue.

Authors:  J W Valvano; J T Allen; H F Bowman
Journal:  J Biomech Eng       Date:  1984-08       Impact factor: 2.097

7.  An isolated rat liver model for the evaluation of thermal techniques to quantify perfusion.

Authors:  J W Valvano; J T Allen; J T Walsh; D J Hnatowich; J F Tomera; H Brunengraber; H F Bowman
Journal:  J Biomech Eng       Date:  1984-08       Impact factor: 2.097

8.  First clinical realization of continuous monitoring of liver microcirculation after transplantation by thermodiffusion.

Authors:  E Klar; T Kraus; M Bredt; B Osswald; N Senninger; C Herfarth; G Otto
Journal:  Transpl Int       Date:  1996       Impact factor: 3.782

9.  Changes in cerebral blood flow and metabolism related to the presence of subdural hematoma.

Authors:  J B Salvant; J P Muizelaar
Journal:  Neurosurgery       Date:  1993-09       Impact factor: 4.654

Review 10.  Cerebral blood flow in severe clinical head injury.

Authors:  G J Bouma; J P Muizelaar
Journal:  New Horiz       Date:  1995-08
View more
  5 in total

1.  Performance assessment of an opto-fluidic phantom mimicking porcine liver parenchyma.

Authors:  Tony J Akl; Travis J King; Ruiqi Long; Michael J McShane; M Nance Ericson; Mark A Wilson; Gerard L Coté
Journal:  J Biomed Opt       Date:  2012-07       Impact factor: 3.170

2.  Cerebral blood flow and autoregulation: current measurement techniques and prospects for noninvasive optical methods.

Authors:  Sergio Fantini; Angelo Sassaroli; Kristen T Tgavalekos; Joshua Kornbluth
Journal:  Neurophotonics       Date:  2016-06-21       Impact factor: 3.593

3.  Regional temperature and quantitative cerebral blood flow responses to cortical spreading depolarization in the rat.

Authors:  Chunyan Li; Raj K Narayan; Ping Wang; Jed A Hartings
Journal:  J Cereb Blood Flow Metab       Date:  2016-01-01       Impact factor: 6.200

4.  A phantom tissue system for the calibration of perfusion measurements.

Authors:  Ashvinikumar V Mudaliar; Brent E Ellis; Patricia L Ricketts; Otto I Lanz; Elaine P Scott; Thomas E Diller
Journal:  J Biomech Eng       Date:  2008-10       Impact factor: 2.097

5.  Effects of magnesium sulfate on supraceliac aortic unclamping in experimental dogs.

Authors:  Youngho Jang; Hyoung Yong Shin; Jin Mo Kim; Mi Young Lee; Dong Yoon Keum
Journal:  J Korean Med Sci       Date:  2005-08       Impact factor: 2.153

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.