Literature DB >> 23942635

Intestinal perfusion monitoring using photoplethysmography.

Tony J Akl1, Mark A Wilson, M Nance Ericson, Gerard L Coté.   

Abstract

In abdominal trauma patients, monitoring intestinal perfusion and oxygen consumption is essential during the resuscitation period. Photoplethysmography is an optical technique potentially capable of monitoring these changes in real time to provide the medical staff with a timely and quantitative measure of the adequacy of resuscitation. The challenges for using optical techniques in monitoring hemodynamics in intestinal tissue are discussed, and the solutions to these challenges are presented using a combination of Monte Carlo modeling and theoretical analysis of light propagation in tissue. In particular, it is shown that by using visible wavelengths (i.e., 470 and 525 nm), the perfusion signal is enhanced and the background contribution is decreased compared with using traditional near-infrared wavelengths leading to an order of magnitude enhancement in the signal-to-background ratio. It was further shown that, using the visible wavelengths, similar sensitivity to oxygenation changes could be obtained (over 50% compared with that of near-infrared wavelengths). This is mainly due to the increased contrast between tissue and blood in that spectral region and the confinement of the photons to the thickness of the small intestine. Moreover, the modeling results show that the source to detector separation should be limited to roughly 6 mm while using traditional near-infrared light, with a few centimeters source to detector separation leads to poor signal-to-background ratio. Finally, a visible wavelength system is tested in an in vivo porcine study, and the possibility of monitoring intestinal perfusion changes is showed.

Entities:  

Mesh:

Year:  2013        PMID: 23942635      PMCID: PMC3739875          DOI: 10.1117/1.JBO.18.8.087005

Source DB:  PubMed          Journal:  J Biomed Opt        ISSN: 1083-3668            Impact factor:   3.170


  40 in total

Review 1.  A brief review on the history of human functional near-infrared spectroscopy (fNIRS) development and fields of application.

Authors:  Marco Ferrari; Valentina Quaresima
Journal:  Neuroimage       Date:  2012-03-28       Impact factor: 6.556

Review 2.  The current status of continuous noninvasive measurement of total, carboxy, and methemoglobin concentration.

Authors:  Micha Y Shamir; Aharon Avramovich; Todd Smaka
Journal:  Anesth Analg       Date:  2011-09-29       Impact factor: 5.108

3.  Skin blood flow differentially affects near-infrared spectroscopy-derived measures of muscle oxygen saturation and blood volume at rest and during dynamic leg exercise.

Authors:  Garry A Tew; Alan D Ruddock; John M Saxton
Journal:  Eur J Appl Physiol       Date:  2010-08-11       Impact factor: 3.078

4.  Effects of cryogenic grinding on soft-tissue optical properties.

Authors:  E Chan; T Menovsky; A J Welch
Journal:  Appl Opt       Date:  1996-08-01       Impact factor: 1.980

5.  Development of a tissue oxygen consumption measurement method based on near-infrared photoplethysmography.

Authors:  Masamichi Nogawa; Shinobu Tanaka; Masahiro Shibata; Ken-Ichi Yamakoshi
Journal:  Conf Proc IEEE Eng Med Biol Soc       Date:  2004

6.  Thermal diffusion probe analysis of perfusion changes in vascular occlusions of rabbit pedicle flaps.

Authors:  Monica B Khot; Peter K M Maitz; Benjamin R Phillips; H Friederick Bowman; Julian J Pribaz; Dennis P Orgill
Journal:  Plast Reconstr Surg       Date:  2005-04       Impact factor: 4.730

7.  Tissue penetration and measuring depth of laser Doppler flowmetry in the gastrointestinal application.

Authors:  K Johansson; H Ahn; J Lindhagen; O Lundgren
Journal:  Scand J Gastroenterol       Date:  1987-11       Impact factor: 2.423

Review 8.  Near-infrared spectroscopy/imaging for monitoring muscle oxygenation and oxidative metabolism in healthy and diseased humans.

Authors:  Takafumi Hamaoka; Kevin K McCully; Valentina Quaresima; Katsuyuki Yamamoto; Britton Chance
Journal:  J Biomed Opt       Date:  2007 Nov-Dec       Impact factor: 3.170

9.  Prediction of amputation wound healing with skin perfusion pressure.

Authors:  H M Adera; K James; J J Castronuovo; M Byrne; R Deshmukh; J Lohr
Journal:  J Vasc Surg       Date:  1995-05       Impact factor: 4.268

Review 10.  Laser Doppler perfusion monitoring and imaging: novel approaches.

Authors:  Anne Humeau; Wiendelt Steenbergen; Henrik Nilsson; Tomas Strömberg
Journal:  Med Biol Eng Comput       Date:  2007-03-06       Impact factor: 3.079

View more
  5 in total

1.  In-silico and in-vitro investigation of a photonic monitor for intestinal perfusion and oxygenation.

Authors:  Mitchell B Robinson; Ryan J Butcher; Mark A Wilson; M Nance Ericson; Gerard L Coté
Journal:  Biomed Opt Express       Date:  2017-07-19       Impact factor: 3.732

2.  A new photoplethysmographic device for continuous assessment of urethral mucosa perfusion: evaluation in a porcine model.

Authors:  Martina Cardinali; Mathieu Magnin; Jeanne-Marie Bonnet-Garin; Christian Paquet; Jean-Yves Ayoub; Bernard Allaouchiche; Stephane Junot
Journal:  J Clin Monit Comput       Date:  2020-05-02       Impact factor: 2.502

3.  In vivo performance of a visible wavelength optical sensor for monitoring intestinal perfusion and oxygenation.

Authors:  Mitchell B Robinson; Anna M Wisniowiecki; Ryan J Butcher; Mark A Wilson; M Nance Ericson; Gerard L Cote
Journal:  J Biomed Opt       Date:  2018-05       Impact factor: 3.170

4.  NIRS-based monitoring of kidney graft perfusion.

Authors:  Stepan Maly; Libor Janousek; Radoslav Bortel; Jan Sebek; Jiri Hospodka; Jiri Skapa; Jiri Fronek
Journal:  PLoS One       Date:  2020-12-02       Impact factor: 3.240

5.  Wireless monitoring of liver hemodynamics in vivo.

Authors:  Tony J Akl; Mark A Wilson; M Nance Ericson; Ethan Farquhar; Gerard L Coté
Journal:  PLoS One       Date:  2014-07-14       Impact factor: 3.240

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.