Assessment of myocardial elastography performance in phantoms under combined physiologic motion configurations with preliminary in vivo feasibility.

S J Okrasinski1, B Ramachandran, E E Konofagou.   

Abstract

Myocardial elastography (ME) is a non-invasive, ultrasound-based strain imaging technique, which can detect and localize abnormalities in myocardial function. By acquiring radio-frequency (RF) frames at high frame rates, the deformation of the myocardium can be estimated, and used to identify regions of abnormal deformation indicative of cardiovascular disease. In this study, the primary objective is to evaluate the effect of torsion on the performance of ME, while the secondary objective is to image inclusions during different motion schemes. Finally, the phantom findings are validated with an in vivo human case. Phantoms of homogeneous stiffness, or containing harder inclusions, were fixed to a pump and motors, and imaged. Incremental displacements were estimated from the RF signals, and accumulated over a motion cycle, and rotation angle, radial strain and circumferential strain were estimated. Phantoms were subjected to four motion schemes: rotation, torsion, deformation, and a combination of torsion and deformation. Sonomicrometry was used as a gold standard during deformation and combined motion schemes. In the rotation scheme, the input and estimated rotation angle agree in both the homogeneous and inclusion phantoms. In the torsion scheme, the estimated rotation angle was found to be highest, closest to the source of torsion and lowest farthest from the source of torsion. In the deformation scheme, if an inclusion was not present, the estimated strain patterns accurately depicted homogeneity, while if an inclusion was present, abnormalities were observed which enabled detection of the inclusion. In addition, no significant rotation was detected. In the combined scheme, if an inclusion was not present, the estimated strain patterns accurately depicted homogeneity, while, if an inclusion was present, abnormalities were observed which enabled detection of the inclusion. Also, torsion was separated from the combined scheme and was found to be similar to the pure torsion findings. This study shows ME to be capable of accurately depicting and distinguishing between different types of motion schemes, and to be sensitive to stiffness changes in localized regions of tissue-mimicking phantoms under physiologic cardiac motion configurations, while strains estimated in the combined motion scheme were noisier than in individual motion schemes. Finally, ME was shown to be capable of distinguishing between deformation and rotation in a normal human heart in vivo.

Entities:  

Mesh:

Year:  2012        PMID: 22892701      PMCID: PMC3704133          DOI: 10.1088/0031-9155/57/17/5633

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  37 in total

1.  Strain rate imaging using two-dimensional speckle tracking.

Authors:  K Kaluzynski; X Chen; S Y Emelianov; A R Skovoroda; M O'Donnell
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2001-07       Impact factor: 2.725

2.  A dual-chamber, thick-walled cardiac phantom for use in cardiac motion and deformation imaging by ultrasound.

Authors:  B Lesniak-Plewinska; S Cygan; K Kaluzynski; J D'hooge; J Zmigrodzki; E Kowalik; M Kordybach; M Kowalski
Journal:  Ultrasound Med Biol       Date:  2010-07       Impact factor: 2.998

3.  In vivo study of myocardial elastography under graded ischemia conditions.

Authors:  Wei-Ning Lee; Jean Provost; Kana Fujikura; Jie Wang; Elisa E Konofagou
Journal:  Phys Med Biol       Date:  2011-02-01       Impact factor: 3.609

4.  Estimation of 3D left ventricular deformation from echocardiography.

Authors:  X Papademetris; A J Sinusas; D P Dione; J S Duncan
Journal:  Med Image Anal       Date:  2001-03       Impact factor: 8.545

5.  Regional myocardial systolic function during acute myocardial ischemia assessed by strain Doppler echocardiography.

Authors:  T Edvardsen; H Skulstad; S Aakhus; S Urheim; H Ihlen
Journal:  J Am Coll Cardiol       Date:  2001-03-01       Impact factor: 24.094

6.  Left ventricular torsion and longitudinal shortening: two fundamental components of myocardial mechanics assessed by tagged cine-MRI in normal subjects.

Authors:  Francesc Carreras; Jaume Garcia-Barnes; Debora Gil; Sandra Pujadas; Chi Hion Li; Ramon Suarez-Arias; Ruben Leta; Xavier Alomar; Manel Ballester; Guillem Pons-Llado
Journal:  Int J Cardiovasc Imaging       Date:  2011-02-09       Impact factor: 2.357

7.  Preliminary validation of angle-independent myocardial elastography using MR tagging in a clinical setting.

Authors:  Wei-Ning Lee; Zhen Qian; Christina L Tosti; Truman R Brown; Dimitris N Metaxas; Elisa E Konofagou
Journal:  Ultrasound Med Biol       Date:  2008-10-26       Impact factor: 2.998

8.  Study of left ventricular rotation and torsion in the acute phase of ST-elevation myocardial infarction by speckle tracking echocardiography.

Authors:  Satish C Govind; Varuna K Gadiyaram; Miguel Quintana; Srinivasiah Saligrama Ramesh; Samir Saha
Journal:  Echocardiography       Date:  2009-09-18       Impact factor: 1.724

9.  Angle-independent and multi-dimensional myocardial elastography--from theory to clinical validation.

Authors:  Wei-Ning Lee; Elisa E Konofagou
Journal:  Ultrasonics       Date:  2008-07-18       Impact factor: 2.890

10.  Increased left ventricular torsion in uncomplicated type 1 diabetic patients: the role of coronary microvascular function.

Authors:  Ganesh Nallur Shivu; Khalid Abozguia; Thanh Trung Phan; Ibrar Ahmed; Rebekah Weaver; Parth Narendran; Martin Stevens; Michael Frenneaux
Journal:  Diabetes Care       Date:  2009-06-09       Impact factor: 19.112

View more
  3 in total

1.  Comparison of cardiac displacement and strain imaging using ultrasound radiofrequency and envelope signals.

Authors:  Chi Ma; Tomy Varghese
Journal:  Ultrasonics       Date:  2012-11-29       Impact factor: 2.890

2.  Electromechanical wave imaging of biologically and electrically paced canine hearts in vivo.

Authors:  Alexandre Costet; Jean Provost; Alok Gambhir; Yevgeniy Bobkov; Peter Danilo; Gerard J J Boink; Michael R Rosen; Elisa E Konofagou
Journal:  Ultrasound Med Biol       Date:  2013-11-14       Impact factor: 2.998

3.  Design, Implementation, and Validation of a Pulsatile Heart Phantom Pump.

Authors:  Volkan Tuncay; Jan Zijlstra; Matthijs Oudkerk; Peter M A van Ooijen
Journal:  J Digit Imaging       Date:  2020-08-10       Impact factor: 4.056

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.