A dual-chamber, thick-walled cardiac phantom for use in cardiac motion and deformation imaging by ultrasound.

B Lesniak-Plewinska1, S Cygan, K Kaluzynski, J D'hooge, J Zmigrodzki, E Kowalik, M Kordybach, M Kowalski.   

Abstract

Determination of the mechanical properties of the myocardium is crucial for cardiac diagnosis. Cardiac strain and strain rate imaging may enable such quantification. To further develop these methodologies, an experimental setup allowing the recording of ultrasonic deformation data in a reproducible manner is necessary. Such setup with biventricular polyvinyl alcohol heart phantoms has been built. To test this setup, segmental longitudinal, radial and circumferential displacement, velocity, strain and strain rate in the phantoms were measured using a clinical ultrasound scanner and commercially available deformation imaging algorithms (based on both tissue velocity imaging and speckle tracking). The model deformation was close to that observed in the human left ventricular wall and was highly reproducible (e.g., the average peak longitudinal strain for the mid- and apical phantom segments equals -15.32 +/- 0.53% and -19 +/- 6% for the ventricle wall). The experimental setup is a valuable source of data for the development of algorithms for deformation estimation. Copyright 2010 World Federation for Ultrasound in Medicine & Biology. Published by Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Year:  2010        PMID: 20620701     DOI: 10.1016/j.ultrasmedbio.2010.04.008

Source DB:  PubMed          Journal:  Ultrasound Med Biol        ISSN: 0301-5629            Impact factor:   2.998


  3 in total

1.  Patient-specific cardiac phantom for clinical training and preprocedure surgical planning.

Authors:  Justin Laing; John Moore; Reid Vassallo; Daniel Bainbridge; Maria Drangova; Terry Peters
Journal:  J Med Imaging (Bellingham)       Date:  2018-03-23

2.  Assessment of myocardial elastography performance in phantoms under combined physiologic motion configurations with preliminary in vivo feasibility.

Authors:  S J Okrasinski; B Ramachandran; E E Konofagou
Journal:  Phys Med Biol       Date:  2012-08-14       Impact factor: 3.609

3.  Development and characterization of rodent cardiac phantoms: comparison with in vivo cardiac imaging.

Authors:  Steven Fortune; Maurits A Jansen; Tom Anderson; Gillian A Gray; Jürgen E Schneider; Peter R Hoskins; Ian Marshall
Journal:  Magn Reson Imaging       Date:  2012-07-06       Impact factor: 2.546

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.