Validation of virtual reality simulation for obstetric ultrasonography: a prospective cross-sectional study.

Christy Burden1, Jessica Preshaw, Paul White, Timothy J Draycott, Simon Grant, Robert Fox.   

Abstract

INTRODUCTION: Ultrasonography is an important skill for obstetricians and gynecologists; however, trainees have highlighted ultrasonography as an area of deficiency in their training. We undertook a prospective cross-sectional comparative study to assess content and construct validity of an ultrasound virtual reality (VR) simulator (UltraSim).
METHODS: Twenty-six physicians and sonographers of varied ultrasonography experience were recruited and divided into trainees (no formal ultrasonography training) and expert (certified) categories. They performed a VR simulation crown-rump length (CRL) ultrasound scan and growth ultrasound scan measuring biparietal diameter, occipitofrontal diameter, abdominal anteroposterior and transverse diameters, and femur length. Maximum pool depth (MPD), placental site, and fetal presentation were also assessed. Outcome measures included the mean absolute deviation and the variance of the absolute deviation from true measurements. Accuracy of determining placental site, fetal presentation, and MPD was assessed. The time taken to perform each type of scan was recorded.
RESULTS: Trainees had significantly greater variation of measurement of CRL (P = 0.025) than the expert group. For late-pregnancy fetal biometry, the absolute deviation and the degree of variability for all measurements differed. These differences were statistically significant (P < 0.05) for all measurements except abdominal diameters and MPD. Trainees took significantly longer time to obtain CRL and fetal biometric scans (P < 0.001). All subjects correctly identified fetal presentation and placental site.
CONCLUSIONS: Clinicians with differing ultrasonography expertise showed differing skill with the UltraSim VR simulator, demonstrating construct validity for skills needed in simulation. Consideration should be given to investigating whether trainees with minimal scanning experience can improve their clinical skills and efficiency with VR simulation.

Mesh:

Year:  2012        PMID: 22878584     DOI: 10.1097/SIH.0b013e3182611844

Source DB:  PubMed          Journal:  Simul Healthc        ISSN: 1559-2332            Impact factor:   1.929


  6 in total

1.  Validation of a virtual reality simulator for the use of transvaginal ultrasonography in gynaecology and early pregnancy.

Authors:  Maya Al-Memar; Srdjan Saso; Shabnam Bobdiwala; Lieveke Ameye; Sharmistha Guha; Karen Joash; Catriona Stalder; Shyamaly Sur; Krishen Moorthy; Dirk Timmerman; Tom Bourne
Journal:  Australas J Ultrasound Med       Date:  2017-05-30

2.  Hybrid simulation using mixed reality for interventional ultrasound imaging training.

Authors:  C Freschi; S Parrini; N Dinelli; M Ferrari; V Ferrari
Journal:  Int J Comput Assist Radiol Surg       Date:  2014-09-12       Impact factor: 2.924

3.  The integration of transabdominal ultrasound simulators into an ultrasound curriculum.

Authors:  K E Orr; S C Hamilton; R Clarke; M Y Adi; C Gutteridge; P Suresh; S J Freeman
Journal:  Ultrasound       Date:  2018-03-08

4.  The McGill simulator for endoscopic sinus surgery (MSESS): a validation study.

Authors:  Rickul Varshney; Saul Frenkiel; Lily H P Nguyen; Meredith Young; Rolando Del Maestro; Anthony Zeitouni; Elias Saad; W Robert J Funnell; Marc A Tewfik
Journal:  J Otolaryngol Head Neck Surg       Date:  2014-10-24

5.  Disaster response team FAST skills training with a portable ultrasound simulator compared to traditional training: pilot study.

Authors:  Michael T Paddock; John Bailitz; Russ Horowitz; Basem Khishfe; Karen Cosby; Michelle J Sergel
Journal:  West J Emerg Med       Date:  2015-03-06

6.  Virtual reality applications to assist pregnant women: a scoping review.

Authors:  Sadrieh Hajesmaeel-Gohari; Fatemeh Sarpourian; Elaheh Shafiei
Journal:  BMC Pregnancy Childbirth       Date:  2021-03-25       Impact factor: 3.007