Literature DB >> 22865766

Mechanical properties of human bone surrounding plateau root form implants retrieved after 0.3-24 years of function.

Marta Baldassarri1, Estevam Bonfante, Marcelo Suzuki, Charles Marin, Rodrigo Granato, Nick Tovar, Paulo G Coelho.   

Abstract

Bone remodeling, along with tissue biomechanics, is critical for the clinical success of endosseous implants. This study evaluated the long-term evolution of the elastic modulus (GPa) and hardness (GPa) of cortical bone around human retrieved plateau root form implants. Thirty implant-in-bone specimens showing no clinical failure were retrieved from patients at different in-vivo times (0.3 to ~24 years) due to retreatment needs. After dehydration, specimens were embedded in methacrylate-based resin, sectioned along the bucco-lingual long axis and fixed to acrylic plates and nondecalcified processed to slides with ~50 μm in thickness. Nanoindentation testing was carried out under wet conditions on bone areas within the first three plateaus. Indentations (n = 120 per implant total) were performed with a maximum load of 300 μN (loading rate: 60 μN/s) followed by a holding and unloading time of 10 s and 2 s, respectively. Elastic modulus (E, GPa) and hardness (H, GPa) were computed. Both E and H values presented increased values as time in vivo elapsed (E: r = 0.84; H: r = 0.78). Significantly higher values for E and H were found after 5 years in vivo (p < 0.001). Maxillary or mandibulary arches or positioning did not affect mechanical properties, nor did implant surface treatment on the long-term bone biomechanical response (E: p ≥ 0.09; H: p ≥ 0.3). This work suggests that human cortical bone around plateau root form implants presents an increase in elastic modulus and hardness during the first 5 years following implantation and presents stable mechanical properties thereafter.
Copyright © 2012 Wiley Periodicals, Inc.

Entities:  

Mesh:

Year:  2012        PMID: 22865766     DOI: 10.1002/jbm.b.32786

Source DB:  PubMed          Journal:  J Biomed Mater Res B Appl Biomater        ISSN: 1552-4973            Impact factor:   3.368


  10 in total

1.  Regeneration of a Pediatric Alveolar Cleft Model Using Three-Dimensionally Printed Bioceramic Scaffolds and Osteogenic Agents: Comparison of Dipyridamole and rhBMP-2.

Authors:  Christopher D Lopez; Paulo G Coelho; Lukasz Witek; Andrea Torroni; Michael I Greenberg; Dean L Cuadrado; Audrey M Guarino; Jonathan M Bekisz; Bruce N Cronstein; Roberto L Flores
Journal:  Plast Reconstr Surg       Date:  2019-08       Impact factor: 4.730

2.  Antiresorptive therapy and dental implant survival: an up to 20-year retrospective cohort study in women.

Authors:  Yu-Chi Cheng; Rolf Ewers; Katherine Morgan; Muneki Hirayama; Laura Murcko; John Morgan; Edmara T P Bergamo; Estevam A Bonfante
Journal:  Clin Oral Investig       Date:  2022-08-24       Impact factor: 3.606

3.  Differences between buccal and lingual bone quality and quantity of peri-implant regions.

Authors:  Do-Gyoon Kim; Kathy L Elias; Yong-Hoon Jeong; Hyun-Jung Kwon; Matthew Clements; William A Brantley; Damian J Lee; Jung-Suk Han
Journal:  J Mech Behav Biomed Mater       Date:  2016-01-02

4.  Mechanical properties of bone tissues surrounding dental implant systems with different treatments and healing periods.

Authors:  Do-Gyoon Kim; Hyun-Jung Kwon; Yong-Hoon Jeong; Erin Kosel; Damian J Lee; Jung-Suk Han; Hye-Lee Kim; Dae-Joon Kim
Journal:  Clin Oral Investig       Date:  2016-02-02       Impact factor: 3.573

5.  Does the systemic administration of L-arginine affect dental implant stability in nicotine consumer dogs?

Authors:  Bijan Movahedian; Mansour Rismanchian; Hooman Navaei; Saeid Tavanafar; Soheil Koushaei
Journal:  Maxillofac Plast Reconstr Surg       Date:  2021-02-10

6.  Histological and Nanomechanical Properties of a New Nanometric Hydroxiapatite Implant Surface. An In Vivo Study in Diabetic Rats.

Authors:  Paula G F P Oliveira; Paulo G Coelho; Edmara T P Bergamo; Lukasz Witek; Cristine A Borges; Fábio B Bezerra; Arthur B Novaes; Sergio L S Souza
Journal:  Materials (Basel)       Date:  2020-12-13       Impact factor: 3.623

7.  Survival rates of ultra-short (<6 mm) compared with short locking-taper implants supporting single crowns in posterior areas: A 5-year retrospective study.

Authors:  Giorgio Lombardo; Annarita Signoriello; Mauro Marincola; Pietro Liboni; Estevam A Bonfante; Pier F Nocini
Journal:  Clin Implant Dent Relat Res       Date:  2021-11-18       Impact factor: 4.259

8.  Short and ultra-short (<6-mm) locking-taper implants supporting single crowns in posterior areas (part II): A 5-year retrospective study on periodontally healthy patients and patients with a history of periodontitis.

Authors:  Giorgio Lombardo; Annarita Signoriello; Alessia Pardo; Xiomara Zilena Serpa Romero; Luis Armando Vila Sierra; Luisa Arévalo Tovar; Mauro Marincola; Pier Francesco Nocini
Journal:  Clin Implant Dent Relat Res       Date:  2022-05-30       Impact factor: 4.259

9.  Randomized Controlled Trial of Posterior Lumbar Interbody Fusion With Ti- and CaP-Nanocoated Polyetheretherketone Cages: Comparative Study of the 1-Year Radiological and Clinical Outcome.

Authors:  Karel Willems; Philippe Lauweryns; Gino Verleye; Johan VAN Goethem
Journal:  Int J Spine Surg       Date:  2019-12-31

10.  Surface characterization and in vivo evaluation of laser sintered and machined implants followed by resorbable-blasting media process: A study in sheep.

Authors:  Michelle Bowers; Daniel Yoo; Charles Marin; Luiz Gil; Nour Shabaka; Matt Goldstein; Malvin Janal; Nick Tovar; Ronaldo Hirata; Estevam Bonfante; Paulo Coelho
Journal:  Med Oral Patol Oral Cir Bucal       Date:  2016-03-01
  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.