Mechanical properties of bone tissues surrounding dental implant systems with different treatments and healing periods.

Do-Gyoon Kim1, Hyun-Jung Kwon2, Yong-Hoon Jeong2, Erin Kosel2, Damian J Lee3, Jung-Suk Han4, Hye-Lee Kim4, Dae-Joon Kim5.   

Abstract

OBJECTIVES: The objective of the current study was to examine whether the nanoindentation parameters can assess the alteration of bone quality resulting from different degrees of bone remodeling between bone tissue ages around the dental implant interface with different treatments and healing periods.
MATERIALS AND METHODS: Dental implants were placed in mandibles of six male dogs. Treatment groups included: resorbable blast media-treated titanium (Ti) implants, alumina-blasted zirconia implants (ATZ), alumina-blasted zirconia implants applied with demineralized bone matrix (ATZ-D), and alumina-blasted zirconia implants applied with rhBMP-2 (ATZ-B). Nanoindentation modulus (E), hardness (H), viscosity (η), and viscoelastic creep (Creep/P max) were measured for new and old bone tissues adjacent to the implants at 3 and 6 weeks of post-implantation. A total of 945 indentations were conducted for 32 implant systems.
RESULTS: Significantly lower E, H, and η but higher Creep/P max were measured for new bone tissues than old bone tissues, independent of treatments at both healing periods (p < 0.001). All nanoindentation parameters were not significantly different between healing periods (p > 0.568). ATZ-D and ATZ-B implants had the stiffer slope of correlation between E and Creep/P max of the new bone tissue than Ti implant (p < 0.039).
CONCLUSIONS: Current results indicated that, in addition to elastic modulus and plastic hardness, measurement of viscoelastic properties of bone tissue surrounding the implant can provide more detailed information to understand mechanical behavior of an implant system. CLINICAL RELEVANCE: Ability of energy absorption in the interfacial bone tissue can play a significant role in the long-term success of a dental implant system.

Entities:  

Keywords:  Bone morphogenetic protein-2; Bone remodeling; Implant interface; Interfacial bone quality; Nanoindentation

Mesh:

Substances:

Year:  2016        PMID: 26832783     DOI: 10.1007/s00784-016-1734-2

Source DB:  PubMed          Journal:  Clin Oral Investig        ISSN: 1432-6981            Impact factor:   3.573


  40 in total

1.  Effects of drying on the mechanical properties of bovine femur measured by nanoindentation.

Authors:  J Y Rho; G M Pharr
Journal:  J Mater Sci Mater Med       Date:  1999-08       Impact factor: 3.896

2.  Influence of alveolar support on stress in periodontal structures.

Authors:  M Ona; N Wakabayashi
Journal:  J Dent Res       Date:  2006-12       Impact factor: 6.116

3.  Relationship between tissue stiffness and degree of mineralization of developing trabecular bone.

Authors:  Lars Mulder; Jan Harm Koolstra; Jaap M J den Toonder; Theo M G J van Eijden
Journal:  J Biomed Mater Res A       Date:  2008-02       Impact factor: 4.396

4.  Mandibular bone remodeling induced by dental implant.

Authors:  Daniel Lin; Qing Li; Wei Li; Naughton Duckmanton; Michael Swain
Journal:  J Biomech       Date:  2009-10-07       Impact factor: 2.712

Review 5.  Biomaterials and biomechanics in dental implant design.

Authors:  J B Brunski
Journal:  Int J Oral Maxillofac Implants       Date:  1988       Impact factor: 2.804

6.  A model for the stability and creep of organic materials.

Authors:  Ingomar L Jäger
Journal:  J Biomech       Date:  2005-07       Impact factor: 2.712

Review 7.  Clinical efficacy of growth factors to enhance tissue repair in oral and maxillofacial reconstruction: a systematic review.

Authors:  Henning Schliephake
Journal:  Clin Implant Dent Relat Res       Date:  2013-07-09       Impact factor: 3.932

8.  Indentation modulus of the alveolar process in dogs.

Authors:  S S Huja; S A Fernandez; K J Hill; P Gulati
Journal:  J Dent Res       Date:  2007-03       Impact factor: 6.116

9.  Elastic properties of human cortical and trabecular lamellar bone measured by nanoindentation.

Authors:  J Y Rho; T Y Tsui; G M Pharr
Journal:  Biomaterials       Date:  1997-10       Impact factor: 12.479

Review 10.  The design of mineralised hard tissues for their mechanical functions.

Authors:  J D Currey
Journal:  J Exp Biol       Date:  1999-12       Impact factor: 3.312

View more
  5 in total

1.  Effect of guided bone regeneration on bone quality surrounding dental implants.

Authors:  Trenton B Johnson; Ben Siderits; Seth Nye; Yong-Hoon Jeong; Seung-Hee Han; In-Chul Rhyu; Jung-Suk Han; Toru Deguchi; F Michael Beck; Do-Gyoon Kim
Journal:  J Biomech       Date:  2018-08-22       Impact factor: 2.712

2.  Effect of Different Surface Treatments on Titanium Dental Implant Micro-Morphology.

Authors:  Gaetano Marenzi; Filomena Impero; Fabio Scherillo; Josè Camilla Sammartino; Antonino Squillace; Gianrico Spagnuolo
Journal:  Materials (Basel)       Date:  2019-03-04       Impact factor: 3.623

3.  Enhanced Bone Remodeling Effects of Low-Modulus Ti-5Zr-3Sn-5Mo-25Nb Alloy Implanted in the Mandible of Beagle Dogs under Delayed Loading.

Authors:  Jing Hu; Xiaobo Zhong; Xiaoming Fu
Journal:  ACS Omega       Date:  2019-11-01

4.  Does the systemic administration of L-arginine affect dental implant stability in nicotine consumer dogs?

Authors:  Bijan Movahedian; Mansour Rismanchian; Hooman Navaei; Saeid Tavanafar; Soheil Koushaei
Journal:  Maxillofac Plast Reconstr Surg       Date:  2021-02-10

5.  Shape Optimization of Bone-Bonding Subperiosteal Devices with Finite Element Analysis.

Authors:  Takeshi Ogasawara; Masayoshi Uezono; Kazuo Takakuda; Masanori Kikuchi; Shoichi Suzuki; Keiji Moriyama
Journal:  Biomed Res Int       Date:  2017-12-17       Impact factor: 3.411

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.