Literature DB >> 17823032

Incidence and volume of pelvic osteolysis at early follow-up with highly cross-linked and noncross-linked polyethylene.

Serena B Leung1, Hiroshi Egawa, Adam Stepniewski, Sarah Beykirch, C Anderson Engh, Charles A Engh.   

Abstract

Highly cross-linked polyethylene has shown decreased wear rates as compared to conventional polyethylene. However, the impact of this decrease on the occurrence of osteolysis remains uncertain. Forty hips implanted with noncross-linked Enduron and 36 implanted with 5-Mrad cross-linked Marathon polyethylene had a computed tomography at a minimum of 5 years after arthroplasty. Polyethylene wear, osteolysis incidence, location, and volume were compared. The incidence of osteolysis was statistically greater for patients with noncross-linked Enduron (11/40, 28%) compared to patients with the moderately cross-linked Marathon (3/36, 8%; P = .04). The average lesion volume for hips with Enduron liners (7.5 +/- 6.7 cm(3)) was significantly greater than the average lesion volume for hips implanted with Marathon liners (1.2 +/- 0.1 cm(3), P = .01). Marathon cross-linked polyethylene has shown to have a decreased incidence and volume of pelvic osteolysis. Longer follow-up is necessary to determine if Marathon cross-linked polyethylene will continue to demonstrate the encouraging improved wear and osteolysis characteristics.

Entities:  

Mesh:

Substances:

Year:  2007        PMID: 17823032     DOI: 10.1016/j.arth.2007.04.006

Source DB:  PubMed          Journal:  J Arthroplasty        ISSN: 0883-5403            Impact factor:   4.757


  17 in total

1.  Highly crosslinked polyethylene does not reduce aseptic loosening in cemented THA 10-year findings of a randomized study.

Authors:  Per-Erik Johanson; Georgios Digas; Peter Herberts; Jonas Thanner; Johan Kärrholm
Journal:  Clin Orthop Relat Res       Date:  2012-11       Impact factor: 4.176

2.  The John Charnley Award: an accurate and sensitive method to separate, display, and characterize wear debris: part 1: polyethylene particles.

Authors:  Fabrizio Billi; Paul Benya; Aaron Kavanaugh; John Adams; Edward Ebramzadeh; Harry McKellop
Journal:  Clin Orthop Relat Res       Date:  2012-02       Impact factor: 4.176

3.  The incidence of acetabular osteolysis in young patients with conventional versus highly crosslinked polyethylene.

Authors:  Nathan A Mall; Ryan M Nunley; Jin Jun Zhu; William J Maloney; Robert L Barrack; John C Clohisy
Journal:  Clin Orthop Relat Res       Date:  2011-02       Impact factor: 4.176

4.  Highly crosslinked polyethylene reduces wear in total hip arthroplasty at 5 years.

Authors:  Jonathan Mutimer; Peter A Devane; Kathryn Adams; J Geoffrey Horne
Journal:  Clin Orthop Relat Res       Date:  2010-12       Impact factor: 4.176

Review 5.  Periprosthetic osteolysis after total hip replacement: molecular pathology and clinical management.

Authors:  Donald W Howie; Susan D Neale; David R Haynes; Oksana T Holubowycz; Margaret A McGee; Lucian B Solomon; Stuart A Callary; Gerald J Atkins; David M Findlay
Journal:  Inflammopharmacology       Date:  2013-10-15       Impact factor: 4.473

6.  CORR Insights®: Prediction of Polyethylene Wear Rates from Gait Biomechanics and Implant Positioning in Total Hip Replacement.

Authors:  Stephen Li
Journal:  Clin Orthop Relat Res       Date:  2017-04-25       Impact factor: 4.176

7.  Wear of a 5 megarad cross-linked polyethylene liner: a 6-year RSA study.

Authors:  Stuart A Callary; David G Campbell; Graham Mercer; Kjell G Nilsson; John R Field
Journal:  Clin Orthop Relat Res       Date:  2013-01-19       Impact factor: 4.176

8.  Role of polyethylene particles in peri-prosthetic osteolysis: A review.

Authors:  Gerald J Atkins; David R Haynes; Donald W Howie; David M Findlay
Journal:  World J Orthop       Date:  2011-10-18

9.  Can the volume of pelvic osteolysis be calculated without using computed tomography?

Authors:  Hiroshi Egawa; Cara C Powers; Sarah E Beykirch; Robert H Hopper; C Anderson Engh; Charles A Engh
Journal:  Clin Orthop Relat Res       Date:  2008-09-27       Impact factor: 4.176

10.  UHMWPE for arthroplasty: past or future?

Authors:  Elena Maria Brach Del Prever; Alessandro Bistolfi; Pierangiola Bracco; Luigi Costa
Journal:  J Orthop Traumatol       Date:  2008-12-24
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.