Literature DB >> 22858333

Miniscrew design and bone characteristics: an experimental study of primary stability.

Marco Migliorati1, Stefano Benedicenti, Alessio Signori, Sara Drago, Fabrizio Barberis, Henry Tournier, Armando Silvestrini-Biavati.   

Abstract

INTRODUCTION: The purpose of this study was to evaluate the correlations between bone characteristics, orthodontic miniscrew designs, and primary stability.
METHODS: Four different miniscrews were placed in pig ribs. The miniscrews were first scanned with a scanning electron microscope to obtain measurable images of their threads. Subsequently, the maximum insertion torque of the screws and the maximum load value in the pullout force tests were measured; furthermore, bone specimen characteristics were analyzed by using cone-beam computed tomography. For each bone sample, the insertion site cortical thickness as well as both cortical and marrow bone density were evaluated. The nonparametric Kendall rank correlation (tau) was used to evaluate the strength of the associations among the characteristics measured. The nonparametric Kruskall-Wallis test was used to evaluate the differences among the groups, and post-hoc comparisons were assessed by using the Nemenyi-Damico-Wolfe-Dunn test.
RESULTS: A significant dependence was found between pitch and maximum insertion torque (tau, -0.49). Positive correlations were also found between pullout force and maximum insertion torque (tau, 0.64), cortical thickness (tau, 0.36), and marrow bone density (tau, 0.35).
CONCLUSIONS: In this in-vitro experimental study, strong correlations were observed among miniscrew geometry, bone characteristics, and primary stability.
Copyright © 2012 American Association of Orthodontists. Published by Mosby, Inc. All rights reserved.

Entities:  

Mesh:

Year:  2012        PMID: 22858333     DOI: 10.1016/j.ajodo.2012.03.029

Source DB:  PubMed          Journal:  Am J Orthod Dentofacial Orthop        ISSN: 0889-5406            Impact factor:   2.650


  14 in total

1.  Histomorphometric evaluation of the effects of various diode lasers and force levels on orthodontic mini screw stability.

Authors:  Merve Goymen; Eren Isman; Lale Taner; Mehmet Kurkcu
Journal:  Photomed Laser Surg       Date:  2015-01       Impact factor: 2.796

2.  Influence of geometric design characteristics on primary stability of orthodontic miniscrews.

Authors:  Eman Saad Radwan; Mona A Montasser; Ahmed Maher
Journal:  J Orofac Orthop       Date:  2018-04-10       Impact factor: 1.938

3.  Analysis of biological and structural factors implicated in the clinical success of orthodontic miniscrews at posterior maxillary interradicular sites.

Authors:  M Palone; A Darsiè; G B Maino; G Siciliani; G A Spedicato; L Lombardo
Journal:  Clin Oral Investig       Date:  2021-11-27       Impact factor: 3.573

4.  Effect of thread depth and thread pitch on the primary stability of miniscrews receiving a torque load : A finite element analysis.

Authors:  Yushan Ye; Weimin Yi; Song Fan; Luodan Zhao; Yansong Yu; Yingjuan Lu; Qinghe Yao; Wei Wang; Shaohai Chang
Journal:  J Orofac Orthop       Date:  2021-09-28       Impact factor: 1.938

5.  Optimization Analysis of Two-Factor Continuous Variable between Thread Depth and Pitch of Microimplant under Toque Force.

Authors:  Yushan Ye; Jiuyang Jiao; Song Fan; Jieying He; Yamei Wang; Qinghe Yao; Wei Wang; Jinsong Li; Shaohai Chang
Journal:  Comput Math Methods Med       Date:  2022-06-20       Impact factor: 2.809

6.  Evaluation of primary stability of innovated orthodontic miniscrew system (STS): An ex-vivo study.

Authors:  Massoud Seifi; Negin-Sadat Matini
Journal:  J Clin Exp Dent       Date:  2016-07-01

7.  Effect of surface treatment on the mechanical stability of orthodontic miniscrews.

Authors:  Yousef Al-Thomali; Sakeenabi Basha; Roshan Noor Mohamed
Journal:  Angle Orthod       Date:  2022-01-01       Impact factor: 2.079

8.  Quantitative evaluation of alveolar cortical bone density in adults with different vertical facial types using cone-beam computed tomography.

Authors:  Fulya Ozdemir; Murat Tozlu; Derya Germec Cakan
Journal:  Korean J Orthod       Date:  2014-01-17       Impact factor: 1.372

9.  Torque Loss After Miniscrew Placement: An In-Vitro Study Followed by a Clinical Trial.

Authors:  Marco Migliorati; Sara Drago; Fabrizio Barberis; Irene Schiavetti; Domenico Dalessandri; Stefano Benedicenti; Armando Silvestrini Biavati
Journal:  Open Dent J       Date:  2016-05-31

Review 10.  Does cortical thickness influence the primary stability of miniscrews?: A systematic review and meta-analysis.

Authors:  Mariana Marquezan; Cláudia Trindade Mattos; Eduardo Franzotti Sant'Anna; Margareth Maria Gomes de Souza; Lucianne Cople Maia
Journal:  Angle Orthod       Date:  2014-04-02       Impact factor: 2.079

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.