Literature DB >> 22833818

Double CT imaging can measure the respiratory movement of small pulmonary tumors during stereotactic ablative radiotherapy.

Ge Shen, Ying-Jie Wang, Hong-Guo Sheng, Xiao-Ping Duan, Jun-Liang Wang, Wei-Jing Zhang, Zhen-Shan Zhou, Guang-Ying Zhu, Ting-Yi Xia.   

Abstract

PURPOSE: The purpose of this study was to investigate the application of double CT imaging to measuring the respiratory movement of small pulmonary tumors during stereotactic ablative radiotherapy (SABR).
METHODS: A total of 122 small pulmonary tumors were measured in 45 patients. CT scans were conducted twice in all 122 tumors, once at the end of quiet inhalation and once at the end of exhalation. CT scans were conducted three times including at the end of quiet inhalation, at the end of exhalation and at free breathing in 36 tumors of 17 patients. The displacement of the tumor center in three directions was measured.
RESULTS: The 3D motion of 122 tumors was 10.10±7.16 mm. On average, the tumors moved 1.96±2.03 mm (rang, 0-9 mm) in the X direction, 5.19±4.69 mm (rang, 0-19 mm) in the Y direction, and 7.38±6.48 mm (rang, 0-26 mm) in the Z direction. The 3D motion of tumors in the lower lung (13.00±7.64 mm) was significantly greater than that in the upper lung (7.15±5.14 mm), P<0.01. The 3D motion of the lower left lung was 16.35±7.31 mm, which was significantly greater than that of the lower right lung (11.40±7.04 mm), P<0.05. Movement in the anterior lung in the Y direction was significantly larger than in the posterior lung. The motion was 7.49±5.43 mm and 4.04±3.82 mm respectively, P<0.01.
CONCLUSIONS: Double CT imaging provides accurate data for determining the outline of each target area during stereotactic ablative radiotherapy plane. The location of small pulmonary tumor foci was significantly affected by respiratory and cardiac motion.

Entities:  

Keywords:  Double CT scan; Respiratory movement; Small pulmonary tumors; Stereotactic ablative radiotherapy

Year:  2012        PMID: 22833818      PMCID: PMC3378231          DOI: 10.3978/j.issn.2072-1439.2012.01.04

Source DB:  PubMed          Journal:  J Thorac Dis        ISSN: 2072-1439            Impact factor:   2.895


  22 in total

1.  Promising clinical outcome of stereotactic body radiation therapy for patients with inoperable Stage I/II non-small-cell lung cancer.

Authors:  Tingyi Xia; Hongqi Li; Qingxuan Sun; Yingjie Wang; Naibin Fan; Yong Yu; Ping Li; Joe Y Chang
Journal:  Int J Radiat Oncol Biol Phys       Date:  2006-06-09       Impact factor: 7.038

2.  Impact of respiratory movement on the computed tomographic images of small lung tumors in three-dimensional (3D) radiotherapy.

Authors:  S Shimizu; H Shirato; K Kagei; T Nishioka; X Bo; H Dosaka-Akita; S Hashimoto; H Aoyama; K Tsuchiya; K Miyasaka
Journal:  Int J Radiat Oncol Biol Phys       Date:  2000-03-15       Impact factor: 7.038

3.  Conformal radiotherapy (CRT) planning for lung cancer: analysis of intrathoracic organ motion during extreme phases of breathing.

Authors:  P Giraud; Y De Rycke; B Dubray; S Helfre; D Voican; L Guo; J C Rosenwald; K Keraudy; M Housset; E Touboul; J M Cosset
Journal:  Int J Radiat Oncol Biol Phys       Date:  2001-11-15       Impact factor: 7.038

4.  Stereotactic single-dose radiotherapy of stage I non-small-cell lung cancer (NSCLC).

Authors:  Holger Hof; Klaus K Herfarth; Marc Münter; Angelika Hoess; Johann Motsch; Michael Wannenmacher; Jürgen Debus J
Journal:  Int J Radiat Oncol Biol Phys       Date:  2003-06-01       Impact factor: 7.038

5.  Tumor location cannot predict the mobility of lung tumors: a 3D analysis of data generated from multiple CT scans.

Authors:  John R van Sörnsen de Koste; Frank J Lagerwaard; Margriet R J Nijssen-Visser; Wilfried J Graveland; Suresh Senan
Journal:  Int J Radiat Oncol Biol Phys       Date:  2003-06-01       Impact factor: 7.038

6.  Quantifying interfraction and intrafraction tumor motion in lung stereotactic body radiotherapy using respiration-correlated cone beam computed tomography.

Authors:  Jean-Pierre Bissonnette; Kevin N Franks; Thomas G Purdie; Douglas J Moseley; Jan-Jakob Sonke; David A Jaffray; Laura A Dawson; Andrea Bezjak
Journal:  Int J Radiat Oncol Biol Phys       Date:  2009-04-22       Impact factor: 7.038

7.  Precise and real-time measurement of 3D tumor motion in lung due to breathing and heartbeat, measured during radiotherapy.

Authors:  Yvette Seppenwoolde; Hiroki Shirato; Kei Kitamura; Shinichi Shimizu; Marcel van Herk; Joos V Lebesque; Kazuo Miyasaka
Journal:  Int J Radiat Oncol Biol Phys       Date:  2002-07-15       Impact factor: 7.038

8.  Portal imaging to assess set-up errors, tumor motion and tumor shrinkage during conformal radiotherapy of non-small cell lung cancer.

Authors:  Sara C Erridge; Yvette Seppenwoolde; Sara H Muller; Marcel van Herk; Katrien De Jaeger; José S A Belderbos; Liesbeth J Boersma; Joos V Lebesque
Journal:  Radiother Oncol       Date:  2003-01       Impact factor: 6.280

9.  Assessing respiration-induced tumor motion and internal target volume using four-dimensional computed tomography for radiotherapy of lung cancer.

Authors:  H Helen Liu; Peter Balter; Teresa Tutt; Bum Choi; Joy Zhang; Catherine Wang; Melinda Chi; Dershan Luo; Tinsu Pan; Sandeep Hunjan; George Starkschall; Isaac Rosen; Karl Prado; Zhongxing Liao; Joe Chang; Ritsuko Komaki; James D Cox; Radhe Mohan; Lei Dong
Journal:  Int J Radiat Oncol Biol Phys       Date:  2007-03-29       Impact factor: 7.038

10.  Local control of metastatic lung tumors treated with SBRT of 48 Gy in four fractions: in comparison with primary lung cancer.

Authors:  Yasushi Hamamoto; Masaaki Kataoka; Motohiro Yamashita; Tetsu Shinkai; Yoshiro Kubo; Yoshifumi Sugawara; Takeshi Inoue; Shinya Sakai; Shoji Aono; Tadaaki Takahashi; Takatoshi Semba; Kotaro Uwatsu
Journal:  Jpn J Clin Oncol       Date:  2009-10-12       Impact factor: 3.019

View more
  5 in total

1.  A millimeter miss is as good as a thousand miles: The role of accurate target localization in lung stereotactic body radiation therapy.

Authors:  Allan Y Chen; Michelle B Chen; Yi-Jen Chen
Journal:  J Thorac Dis       Date:  2012-04-01       Impact factor: 2.895

2.  Imaging for high-precision thoracic radiotherapy.

Authors:  Sashendra Senthi; Suresh Senan
Journal:  J Thorac Dis       Date:  2012-04-01       Impact factor: 2.895

3.  Comparing Pulmonary Nodule Location During Electromagnetic Bronchoscopy With Predicted Location on the Basis of Two Virtual Airway Maps at Different Phases of Respiration.

Authors:  Brian S Furukawa; Nicholas J Pastis; Nichole T Tanner; Alexander Chen; Gerard A Silvestri
Journal:  Chest       Date:  2017-06-16       Impact factor: 9.410

4.  Stereotactic body radiation therapy for centrally-located lung tumors.

Authors:  Ge Shen; Ying-Jie Wang; Wen-Jiang Shen; Zhen-Shan Zhou; Jun-Liang Wang; Hong-Guo Sheng; DA-Peng Dong; Ming Zhou; Gang Yang; Qin-Wen Wang; Yanjun Zeng
Journal:  Oncol Lett       Date:  2014-01-21       Impact factor: 2.967

5.  Safety and efficacy of intensity-modulated stereotactic body radiotherapy using helical tomotherapy for lung cancer and lung metastasis.

Authors:  Aiko Nagai; Yuta Shibamoto; Masanori Yoshida; Koji Inoda; Yuzo Kikuchi
Journal:  Biomed Res Int       Date:  2014-06-04       Impact factor: 3.411

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.