Literature DB >> 22833156

A MEMS electrochemical bellows actuator for fluid metering applications.

Roya Sheybani1, Heidi Gensler, Ellis Meng.   

Abstract

We present a high efficiency wireless MEMS electrochemical bellows actuator capable of rapid and repeatable delivery of boluses for fluid metering and drug delivery applications. Nafion®-coated Pt electrodes were combined with Parylene bellows filled with DI water to form the electrolysis-based actuator. The performance of actuators with several bellows configurations was compared for a range of applied currents (1-10 mA). Up to 75 boluses were delivered with an average pumping flow rate of 114.40 ± 1.63 μL/min. Recombination of gases into water, an important factor in repeatable and reliable actuation, was studied for uncoated and Nafion®-coated actuators. Real-time pressure measurements were conducted and the effects of temperature, physiological back pressure, and drug viscosity on delivery performance were investigated. Lastly, we present wireless powering of the actuator using a class D inductive powering system that allowed for repeatable delivery with less than 2 % variation in flow rate values.

Entities:  

Mesh:

Substances:

Year:  2013        PMID: 22833156      PMCID: PMC3755886          DOI: 10.1007/s10544-012-9685-0

Source DB:  PubMed          Journal:  Biomed Microdevices        ISSN: 1387-2176            Impact factor:   2.838


  8 in total

1.  Electrolytic actuators: alternative, high-performance, material-based devices.

Authors:  Colin G Cameron; Michael S Freund
Journal:  Proc Natl Acad Sci U S A       Date:  2002-06-11       Impact factor: 11.205

2.  An electrochemical pumping system for on-chip gradient generation.

Authors:  Jun Xie; Yunan Miao; Jason Shih; Qing He; Jun Liu; Yu-Chong Tai; Terry D Lee
Journal:  Anal Chem       Date:  2004-07-01       Impact factor: 6.986

3.  An implantable MEMS micropump system for drug delivery in small animals.

Authors:  Heidi Gensler; Roya Sheybani; Po-Ying Li; Ronalee Lo Mann; Ellis Meng
Journal:  Biomed Microdevices       Date:  2012-06       Impact factor: 2.838

4.  Implementation of wireless power transfer and communications for an implantable ocular drug delivery system.

Authors:  T B Tang; S Smith; B W Flynn; J T M Stevenson; A M Gundlach; H M Reekie; A F Murray; D Renshaw; B Dhillon; A Ohtori; Y Inoue; J G Terry; A J Walton
Journal:  IET Nanobiotechnol       Date:  2008-09       Impact factor: 1.847

5.  A Parylene Bellows Electrochemical Actuator.

Authors:  Po-Ying Li; Roya Sheybani; Christian A Gutierrez; Jonathan T W Kuo; Ellis Meng
Journal:  J Microelectromech Syst       Date:  2010-01-01       Impact factor: 2.417

Review 6.  Microemulsions as transdermal drug delivery vehicles.

Authors:  Anna Kogan; Nissim Garti
Journal:  Adv Colloid Interface Sci       Date:  2006-07-14       Impact factor: 12.984

Review 7.  Rhythmic pattern in pain and their chronotherapy.

Authors:  Bernard Bruguerolle; Gaston Labrecque
Journal:  Adv Drug Deliv Rev       Date:  2007-07-13       Impact factor: 15.470

8.  Local drug delivery with a self-contained, programmable, microfluidic system.

Authors:  J Fiering; M J Mescher; E E Leary Swan; M E Holmboe; B A Murphy; Z Chen; M Peppi; W F Sewell; M J McKenna; S G Kujawa; J T Borenstein
Journal:  Biomed Microdevices       Date:  2009-06       Impact factor: 2.838

  8 in total
  5 in total

1.  A Wireless Implantable Micropump for Chronic Drug Infusion Against Cancer.

Authors:  Angelica Cobo; Roya Sheybani; Heidi Tu; Ellis Meng
Journal:  Sens Actuators A Phys       Date:  2016-03-01       Impact factor: 3.407

2.  Acceleration Techniques for Recombination of Gases in Electrolysis Microactuators with Nafion®-Coated Electrocatalyst.

Authors:  Roya Sheybani; Ellis Meng
Journal:  Sens Actuators B Chem       Date:  2015-12-31       Impact factor: 7.460

Review 3.  Techniques and Considerations in the Microfabrication of Parylene C Microelectromechanical Systems.

Authors:  Jessica Ortigoza-Diaz; Kee Scholten; Christopher Larson; Angelica Cobo; Trevor Hudson; James Yoo; Alex Baldwin; Ahuva Weltman Hirschberg; Ellis Meng
Journal:  Micromachines (Basel)       Date:  2018-08-22       Impact factor: 2.891

4.  Wireless, battery-free push-pull microsystem for membrane-free neurochemical sampling in freely moving animals.

Authors:  Guangfu Wu; Ian Heck; Nannan Zhang; Glenn Phaup; Xincheng Zhang; Yixin Wu; David E Stalla; Zhengyan Weng; He Sun; Huijie Li; Zhe Zhang; Shinghua Ding; De-Pei Li; Yi Zhang
Journal:  Sci Adv       Date:  2022-02-23       Impact factor: 14.136

5.  Neural probe system for behavioral neuropharmacology by bi-directional wireless drug delivery and electrophysiology in socially interacting mice.

Authors:  Yousang Yoon; Hyogeun Shin; Donghak Byun; Jiwan Woo; Yakdol Cho; Nakwon Choi; Il-Joo Cho
Journal:  Nat Commun       Date:  2022-09-21       Impact factor: 17.694

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.