Literature DB >> 22822419

Two dimensional extensible array configuration for EMCCD-based solid state x-ray detectors.

P Sharma1, S N Swetadri Vasan, A N Cartwright, A H Titus, D R Bednarek, S Rudin.   

Abstract

We have designed and developed from the discrete component level a high resolution dynamic x- ray detector to be used for fluoroscopic and angiographic medical imaging. The heart of the detector is a 1024 × 1024 pixel electron multiplying charge coupled device (EMCCD) with a pixel size of 13 × 13 μm(2) (Model CCD201-20, e2v Technologies, Inc.), bonded to a fiber optic plate (FOP), and optically coupled to a 350 μm thick micro-columnar CsI(TI) scintillator via a fiber optic taper (FOT). Our aim is to design an array of these detectors that could be extended to any arbitrary X × Y size in two dimensions to provide a larger field of view (FOV). A physical configuration for a 3×3 array is presented that includes two major sub-systems. First is an optical front end that includes (i) a phosphor to convert the x-ray photons into light photons, and (ii) a fused array of FOTs that focuses light photons from the phosphor onto an array of EMCCD's optically coupled using FOPs. Second is an electronic front end that includes (i) an FPGA board used for generating clocks and for data acquisition (ii) driver boards to drive and digitize the analog output from the EMCCDs, (iii) a power board, and (iv) headboards to hold the EMCCD's while they are connected to their respective driver board using flex cables. This configuration provides a larger FOV as well as region-of- interest (ROI) high-resolution imaging as required by modern neurovascular procedures.

Entities:  

Year:  2012        PMID: 22822419      PMCID: PMC3399546          DOI: 10.1117/12.911354

Source DB:  PubMed          Journal:  Proc SPIE Int Soc Opt Eng        ISSN: 0277-786X


  5 in total

1.  Accurate characterization of image intensifier distortion.

Authors:  S Rudin; D R Bednarek; R Wong
Journal:  Med Phys       Date:  1991 Nov-Dec       Impact factor: 4.071

2.  Novel Multiplexer to Enable Multiple-Module Imaging with Adjustable High Spatial Resolution and Predetermined Display Bandwidth for Array Medical Imaging Systems.

Authors:  P Sharma; A H Titus; B Qu; Y Huang; W Wang; A Kuhls-Gilcrist; A N Cartwright; D R Bednarek; S Rudin
Journal:  IEEE Nucl Sci Symp Conf Rec (1997)       Date:  2010

3.  Component Level Modular Design of a Solid State X-ray Image Intensifier for an M×N Array.

Authors:  Ying Huang; Bin Qu; Prateek Sharma; Andrew Kuhls-Gilcrist; Weiyuan Wang; Albert H Titus; Alexander N Cartwright; Daniel R Bednarek; Stephen Rudin
Journal:  IEEE Nucl Sci Symp Conf Rec (1997)       Date:  2010-10-30

4.  X-ray imaging performance of structured cesium iodide scintillators.

Authors:  Wei Zhao; Goran Ristic; J A Rowlands
Journal:  Med Phys       Date:  2004-09       Impact factor: 4.071

5.  Component analysis of a new Solid State X-ray Image Intensifier (SSXII) using photon transfer and Instrumentation Noise Equivalent Exposure (INEE) measurements.

Authors:  Andrew Kuhls-Gilcrist; Daniel R Bednarek; Stephen Rudin
Journal:  Proc SPIE Int Soc Opt Eng       Date:  2009-01-01
  5 in total
  3 in total

1.  Quantitative analysis of an enlarged area Solid State X-ray Image Intensifier (SSXII) detector based on Electron Multiplying Charge Coupled Device (EMCCD) technology.

Authors:  Vasan S N Swetadri; P Sharma; V Singh; A Jain; Ciprian N Ionita; A H Titus; A N Cartwright; D R Bednarek; S Rudin
Journal:  Proc SPIE Int Soc Opt Eng       Date:  2013-03-06

2.  Image acquisition, geometric correction and display of images from a 2×2 x-ray detector array based on Electron Multiplying Charge Coupled Device (EMCCD) technology.

Authors:  S N Swetadri Vasan; P Sharma; Ciprian N Ionita; A H Titus; A N Cartwright; D R Bednarek; S Rudin
Journal:  Proc SPIE Int Soc Opt Eng       Date:  2013-03-06

3.  Intrinsic and total system performance evaluation for a newly developed Solid State X-ray Image Intensifier (SSXII) detector.

Authors:  V Singh; S N Swetadri Vasan; A Jain; P Sharma; D R Bednarek; S Rudin
Journal:  Proc SPIE Int Soc Opt Eng       Date:  2013-03-06
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.