Literature DB >> 22817847

Characterization of a computed tomography iterative reconstruction algorithm by image quality evaluations with an anthropomorphic phantom.

O Rampado1, L Bossi, D Garabello, O Davini, R Ropolo.   

Abstract

OBJECTIVE: This study aims to investigate the consequences on dose and image quality of the choices of different combinations of NI and adaptive statistical iterative reconstruction (ASIR) percentage, the image quality parameters of GE CT equipment.
METHODS: An anthropomorphic phantom was used to simulate the chest and upper abdomen of a standard weight patient. Images were acquired with tube current modulation and different values of noise index, in the range 10-22 for a slice thickness of 5mm and a tube voltage of 120 kV. For each selected noise index, several image series were reconstructed using different percentages of ASIR (0, 40, 50, 60, 70, 100). Quantitative noise was assessed at different phantom locations. Computed tomography dose index (CTDI) and dose length products (DLP) were recorded. Three radiologists reviewed the images in a blinded and randomized manner and assessed the subjective image quality by comparing the image series with the one acquired with the reference protocol (noise index 14, ASIR 40%). The perceived noise, contrast, edge sharpness and overall quality were graded on a scale from -2 (much worse) to +2 (much better).
RESULTS: A repeatable trend of noise reduction versus the percentage of ASIR was observed for different noise levels and phantom locations. The different combinations of noise index and percentage of ASIR to obtain a desired dose reduction were assessed. The subjective image quality evaluation evidenced a possible dose reduction between 24 and 40% as a consequence of an increment of ASIR percentage to 50 or 70%, respectively.
CONCLUSION: These results highlighted that the same patient dose reduction can be obtained with several combinations of noise index and percentages of ASIR, providing a model with which to choose these acquisition parameters in future optimization studies, with the aim of reducing patient dose by maintaining image quality in diagnostic levels.
Copyright © 2012 Elsevier Ireland Ltd. All rights reserved.

Entities:  

Mesh:

Year:  2012        PMID: 22817847     DOI: 10.1016/j.ejrad.2012.06.017

Source DB:  PubMed          Journal:  Eur J Radiol        ISSN: 0720-048X            Impact factor:   3.528


  5 in total

1.  Aortic CT angiography dose reduction: investigation of optimal noise index and iterative algorithm strength in combination with low kV.

Authors:  Osvaldo Rampado; Stefania Busso; Domenica Garabello; Ezio Marengo; Marco Valerio; Simona Capello; Simona Veglia; Ottavio Davini; Roberto Ropolo
Journal:  Radiol Med       Date:  2015-12-16       Impact factor: 3.469

2.  Emerging techniques for dose optimization in abdominal CT.

Authors:  Ravi K Kaza; Joel F Platt; Mitchell M Goodsitt; Mahmoud M Al-Hawary; Katherine E Maturen; Ashish P Wasnik; Amit Pandya
Journal:  Radiographics       Date:  2014 Jan-Feb       Impact factor: 5.333

3.  Development of pediatric CT protocols for specific scanners: why bother?

Authors:  Dianna D Cody
Journal:  Pediatr Radiol       Date:  2014-10-11

4.  Combining automatic tube current modulation with adaptive statistical iterative reconstruction for low-dose chest CT screening.

Authors:  Jiang-Hong Chen; Er-Hu Jin; Wen He; Li-Qin Zhao
Journal:  PLoS One       Date:  2014-04-01       Impact factor: 3.240

5.  Dual Energy CT (DECT) Monochromatic Imaging: Added Value of Adaptive Statistical Iterative Reconstructions (ASIR) in Portal Venography.

Authors:  Liqin Zhao; Sebastian Winklhofer; Rong Jiang; Xinlian Wang; Wen He
Journal:  PLoS One       Date:  2016-06-17       Impact factor: 3.240

  5 in total