Literature DB >> 22814527

Laser in situ keratomileusis enhancements with the Ziemer FEMTO LDV femtosecond laser following previous LASIK treatments.

Juhani Pietilä1, Anne Huhtala, Petri Mäkinen, Hannu Uusitalo.   

Abstract

BACKGROUND: The aim of this paper is to present the accuracy, predictability, and safety outcomes of LASIK enhancements performed with the FEMTO LDV femtosecond laser (Ziemer Ophthalmic Systems, Port, Switzerland) and the Allegretto Wave Concerto 500 Hz excimer laser (Wavelight AG, Erlangen, Germany), following previous LASIK treatments.
METHODS: FEMTO LDV was used for flap creation in 85 previously LASIK-treated eyes of 62 patients. The intended flap thickness was 90 μm in 81 eyes and 140 μm in 4 eyes. The size of the suction ring was 9.0 mm in 72 eyes and 9.5 mm in 13 eyes. Flap dimensions were measured and correlated to preoperative characteristics.
RESULTS: With the intended flap thickness of 90 μm in previously LASIK-treated eyes, the actual flap thickness was 90.2 ± 6.6 μm (range 80-122), and the flap diameter was 9.2 ± 0.2 mm (range 8.7-9.9). The mean hinge length was 4.0 ± 0.2 mm (range 3.0-4.8). Flap thickness correlated positively with patient age and hinge length. Complications were reported in 12 eyes (14.1 %). Most of the complications were very mild, and none of them prevented further refractive laser treatment. One eye lost two Snellen lines of best spectacle-corrected visual acuity.
CONCLUSIONS: Femtosecond LASIK enhancement is warranted only in rare cases. Surgical experience is needed and special caution must be practiced. For cases of a primary free cap, femtosecond LASIK is not recommended.

Entities:  

Mesh:

Year:  2012        PMID: 22814527     DOI: 10.1007/s00417-012-2110-9

Source DB:  PubMed          Journal:  Graefes Arch Clin Exp Ophthalmol        ISSN: 0721-832X            Impact factor:   3.117


  17 in total

1.  Comparison of the IntraLase femtosecond laser and mechanical keratomes for laser in situ keratomileusis.

Authors:  Guy M Kezirian; Karl G Stonecipher
Journal:  J Cataract Refract Surg       Date:  2004-04       Impact factor: 3.351

2.  Flap dimensions created with the IntraLase FS laser.

Authors:  Perry S Binder
Journal:  J Cataract Refract Surg       Date:  2004-01       Impact factor: 3.351

3.  Accuracy and reproducibility of artemis central flap thickness and visual outcomes of LASIK with the Carl Zeiss Meditec VisuMax femtosecond laser and MEL 80 excimer laser platforms.

Authors:  Dan Z Reinstein; Timothy J Archer; Marine Gobbe; Neil Johnson
Journal:  J Refract Surg       Date:  2010-02-12       Impact factor: 3.573

4.  Femtosecond laser-assisted corneal flap cuts: morphology, accuracy, and histopathology.

Authors:  Mike P Holzer; Tanja M Rabsilber; Gerd U Auffarth
Journal:  Invest Ophthalmol Vis Sci       Date:  2006-07       Impact factor: 4.799

5.  Comparison of laser in situ keratomileusis reoperation outcomes with the Moria M2 head 90 and 130 following previous photorefractive keratectomy or laser in situ keratomileusis.

Authors:  Antti Pitkänen; Juhani Pietilä; Petri Mäkinen; Anne Huhtala; Hannu Uusitalo
Journal:  Acta Ophthalmol       Date:  2009-03-12       Impact factor: 3.761

6.  LASIK flap creation with the Ziemer femtosecond laser in 787 consecutive eyes.

Authors:  Juhani Pietilä; Anne Huhtala; Markus Jääskeläinen; Jarmo Jylli; Petri Mäkinen; Hannu Uusitalo
Journal:  J Refract Surg       Date:  2010-01-11       Impact factor: 3.573

7.  Accuracy and precision of LASIK flap thickness using the IntraLase femtosecond laser in 1000 consecutive cases.

Authors:  Gerard Sutton; Chris Hodge
Journal:  J Refract Surg       Date:  2008-10       Impact factor: 3.573

8.  LASIK for myopia using the Zeiss VisuMax femtosecond laser and MEL 80 excimer laser.

Authors:  Marcus Blum; Kathleen Kunert; Annika Gille; Walter Sekundo
Journal:  J Refract Surg       Date:  2009-04       Impact factor: 3.573

9.  Reproducibility of flap thickness with IntraLase FS and Moria LSK-1 and M2 microkeratomes.

Authors:  Jonathan H Talamo; Jeremy Meltzer; John Gardner
Journal:  J Refract Surg       Date:  2006-06       Impact factor: 3.573

10.  Corneal flap measurements in laser in situ keratomileusis using the Moria M2 automated microkeratome.

Authors:  Juhani Pietilä; Petri Mäkinen; Sakari Suominen; Anne Huhtala; Hannu Uusitalo
Journal:  J Refract Surg       Date:  2005 Jul-Aug       Impact factor: 3.573

View more
  2 in total

1.  Rescue of primary incomplete microkeratome flap with secondary femtosecond laser flap in LASIK.

Authors:  E A Razgulyaeva
Journal:  Case Rep Ophthalmol Med       Date:  2014-11-23

2.  Digital analysis of flap parameter accuracy and objective assessment of opaque bubble layer in femtosecond laser-assisted LASIK: a novel technique.

Authors:  A John Kanellopoulos; George Asimellis
Journal:  Clin Ophthalmol       Date:  2013-02-15
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.