Literature DB >> 20163075

Accuracy and reproducibility of artemis central flap thickness and visual outcomes of LASIK with the Carl Zeiss Meditec VisuMax femtosecond laser and MEL 80 excimer laser platforms.

Dan Z Reinstein1, Timothy J Archer, Marine Gobbe, Neil Johnson.   

Abstract

PURPOSE: To quantify the accuracy and reproducibility of central flap thickness for flaps created with the VisuMax femtosecond laser system.
METHODS: This was a prospective study of 24 eyes of 12 myopic LASIK patients. The VisuMax femtosecond laser was used to create flaps with an intended central flap thickness of 110 microm. Artemis 1 very high-frequency digital ultrasound scans were performed preoperatively and 3 months postoperatively. Central flap thickness was calculated as the addition of the preoperative epithelial thickness and the postoperative stromal component of the flap. Descriptive statistics (mean, standard deviation, minimum, maximum, and range) of central Reinstein Flap Thickness were calculated for all flaps. Central flap thickness accuracy was calculated as the difference between the mean and intended flap thickness. Reproducibility was evaluated as the flap thickness standard deviation between eyes.
RESULTS: At 3 months, mean central Reinstein Flap Thickness was 112.3+/-7.9 microm (range: 102.6 to 132.9 microm). The accuracy was +2.3 microm and reproducibility was 7.9 microm. On average, the flap diameter was 0.47+/-0.21 mm greater than the intended flap diameter.
CONCLUSIONS: The VisuMax femtosecond laser system was found to create flaps accurate to the intended thickness in the center with a low standard deviation, which will help reduce the risk of obtaining an excessively thick flap.

Entities:  

Mesh:

Year:  2010        PMID: 20163075     DOI: 10.3928/1081597X-20100121-06

Source DB:  PubMed          Journal:  J Refract Surg        ISSN: 1081-597X            Impact factor:   3.573


  17 in total

1.  Simulation of the temperature increase in human cadaver retina during direct illumination by 150-kHz femtosecond laser pulses.

Authors:  Hui Sun; Nora Hosszufalusi; Eric R Mikula; Tibor Juhasz
Journal:  J Biomed Opt       Date:  2011-10       Impact factor: 3.170

2.  Stromal lenticule transplantation for management of corneal perforations; one year results.

Authors:  Mohamed Samy Abd Elaziz; Adel Galal Zaky; Abdel Rahman El SaebaySarhan
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2017-04-13       Impact factor: 3.117

3.  Artemis very high frequency digital ultrasound-guided femtosecond laser recut after flap complication.

Authors:  Dan Z Reinstein; Zachary Dickeson; Timothy J Archer; Marine Gobbe
Journal:  Digit J Ophthalmol       Date:  2014-09-14

4.  Flap thickness in eyes with ectasia after laser in situ keratomileusis.

Authors:  J Bradley Randleman; Carolyn B Hebson; Paul M Larson
Journal:  J Cataract Refract Surg       Date:  2012-03-16       Impact factor: 3.351

5.  Laser in situ keratomileusis enhancements with the Ziemer FEMTO LDV femtosecond laser following previous LASIK treatments.

Authors:  Juhani Pietilä; Anne Huhtala; Petri Mäkinen; Hannu Uusitalo
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2012-07-20       Impact factor: 3.117

6.  Analysis of microkeratome thin flap architecture using Fourier-domain optical coherence tomography.

Authors:  Karolinne Maia Rocha; J Bradley Randleman; R Doyle Stulting
Journal:  J Refract Surg       Date:  2011-08-19       Impact factor: 3.573

7.  Flap characteristics, predictability, and safety of the Ziemer FEMTO LDV femtosecond laser with the disposable suction ring for LASIK.

Authors:  J Pietilä; A Huhtala; P Mäkinen; H Uusitalo
Journal:  Eye (Lond)       Date:  2013-11-15       Impact factor: 3.775

8.  Repeatability of layered corneal pachymetry with the artemis very high-frequency digital ultrasound arc-scanner.

Authors:  Dan Z Reinstein; Timothy J Archer; Marine Gobbe; Ronald H Silverman; D Jackson Coleman
Journal:  J Refract Surg       Date:  2009-11-16       Impact factor: 3.573

9.  Fibrinogen, riboflavin, and UVA to immobilize a corneal flap--conditions for tissue adhesion.

Authors:  Stacy L Littlechild; Gage Brummer; Yuntao Zhang; Gary W Conrad
Journal:  Invest Ophthalmol Vis Sci       Date:  2012-06-26       Impact factor: 4.799

10.  One-Year Visual and Refractive Outcomes following LASIK for Myopia and Myopic Astigmatism with MEL 90 versus Schwind Amaris 750S Excimer Laser: A Comparative Study.

Authors:  Sheetal Brar; Dishitha P Rathod; C R Roopashree; Sri Ganesh
Journal:  J Ophthalmol       Date:  2021-06-25       Impact factor: 1.909

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.