Literature DB >> 22809847

Minimizing the exposure of airborne pathogens by upper-room ultraviolet germicidal irradiation: an experimental and numerical study.

Y Yang1, W Y Chan, C L Wu, R Y C Kong, A C K Lai.   

Abstract

There has been increasing interest in the use of upper-room ultraviolet germicidal irradiation (UVGI) because of its proven effectiveness in disinfecting airborne pathogens. An improved drift flux mathematical model is developed for optimizing the design of indoor upper-room UVGI systems by predicting the distribution and inactivation of bioaerosols in a ventilation room equipped with a UVGI system. The model takes into account several bacteria removal mechanisms such as convection, turbulent diffusion, deposition and UV inactivation. Before applying the model, the natural die-off rate and susceptibility constants of bioaerosols were measured experimentally. Two bacteria aerosols, Escherichia coli and Serratia marcescens, were tested for this purpose. It was found out that the general decay trend of the bioaerosol concentration predicted by the numerical model agrees well with the experimental measurements. The modelling results agree better with experimental observations for the case when the UVGI inactivation mechanism dominates at the upper-room region than for the case without UVGI. The numerical results also illustrate that the spatial distribution of airborne bacteria was influenced by both air-flow pattern and irradiance distribution. In addition to predicting the local variation of concentration, the model assesses the overall performance of an upper-room UVGI system. This model has great potential for optimizing the design of indoor an upper-room UVGI systems.

Entities:  

Mesh:

Substances:

Year:  2012        PMID: 22809847      PMCID: PMC3481576          DOI: 10.1098/rsif.2012.0439

Source DB:  PubMed          Journal:  J R Soc Interface        ISSN: 1742-5662            Impact factor:   4.118


  20 in total

1.  THE PHYSICAL FACTORS IN PHOTOTHERAPY.

Authors:  J E Barnard; H de R Morgan
Journal:  Br Med J       Date:  1903-11-14

Review 2.  Clearing the air. The theory and application of ultraviolet air disinfection.

Authors:  R L Riley; E A Nardell
Journal:  Am Rev Respir Dis       Date:  1989-05

3.  Removal of contaminants released from room surfaces by displacement and mixing ventilation: modeling and validation.

Authors:  G He; X Yang; J Srebric
Journal:  Indoor Air       Date:  2005-10       Impact factor: 5.770

4.  Fundamental factors affecting upper-room ultraviolet germicidal irradiation - part II. Predicting effectiveness.

Authors:  Stephen N Rudnick; Melvin W First
Journal:  J Occup Environ Hyg       Date:  2007-05       Impact factor: 2.155

5.  Impact of environmental factors on efficacy of upper-room air ultraviolet germicidal irradiation for inactivating airborne mycobacteria.

Authors:  Peng Xu; Elmira Kujundzic; Jordan Peccia; Millie P Schafer; Gene Moss; Mark Hernandez; Shelly L Miller
Journal:  Environ Sci Technol       Date:  2005-12-15       Impact factor: 9.028

6.  Photoreactivation in airborne Mycobacterium parafortuitum.

Authors:  J Peccia; M Hernandez
Journal:  Appl Environ Microbiol       Date:  2001-09       Impact factor: 4.792

7.  Application of Lagrangian particle transport model to tuberculosis (TB) bacteria UV dosing in a ventilated isolation room.

Authors:  A Alani; I E Barton; M J Seymour; L C Wrobel
Journal:  Int J Environ Health Res       Date:  2001-09       Impact factor: 3.411

8.  Ultraviolet susceptibility of BCG and virulent tubercle bacilli.

Authors:  R L Riley; M Knight; G Middlebrook
Journal:  Am Rev Respir Dis       Date:  1976-04

9.  The characterization of upper-room ultraviolet germicidal irradiation in inactivating airborne microorganisms.

Authors:  Gwangpyo Ko; Melvin W First; Harriet A Burge
Journal:  Environ Health Perspect       Date:  2002-01       Impact factor: 9.031

10.  Numerical modeling of exhaled droplet nuclei dispersion and mixing in indoor environments.

Authors:  K W Mui; L T Wong; C L Wu; Alvin C K Lai
Journal:  J Hazard Mater       Date:  2009-01-20       Impact factor: 10.588

View more
  5 in total

1.  Modeling Biphasic Environmental Decay of Pathogens and Implications for Risk Analysis.

Authors:  Andrew F Brouwer; Marisa C Eisenberg; Justin V Remais; Philip A Collender; Rafael Meza; Joseph N S Eisenberg
Journal:  Environ Sci Technol       Date:  2017-02-08       Impact factor: 9.028

2.  Lagrangian modeling of inactivation of airborne microorganisms by in-duct ultraviolet lamps.

Authors:  Yi Yang; Huihui Zhang; Alvin Ck Lai
Journal:  Build Environ       Date:  2020-11-21       Impact factor: 6.456

3.  Ceiling impact on air disinfection performance of Upper-Room Germicidal Ultraviolet (UR-GUV).

Authors:  Shengwei Zhu; Tong Lin; Lingzhe Wang; Edward A Nardell; Richard L Vincent; Jelena Srebric
Journal:  Build Environ       Date:  2022-08-31       Impact factor: 7.093

4.  A pilot study on the disinfection efficacy of localized UV on the flushing-generated spread of pathogens.

Authors:  A C K Lai; S S Nunayon; T F Tan; W S Li
Journal:  J Hazard Mater       Date:  2018-07-03       Impact factor: 10.588

5.  A tracing method of airborne bacteria transmission across built environments.

Authors:  Zonggang Li; Hongning Wang; Weichao Zheng; Baoming Li; Yongxiang Wei; Jinxin Zeng; Changwei Lei
Journal:  Build Environ       Date:  2019-08-09       Impact factor: 6.456

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.