Literature DB >> 11781170

The characterization of upper-room ultraviolet germicidal irradiation in inactivating airborne microorganisms.

Gwangpyo Ko1, Melvin W First, Harriet A Burge.   

Abstract

In this study, we explored the efficacy of upper-room ultraviolet germicidal irradiation (UVGI) in reducing the concentration of Serratia marcescens and Mycobacterium bovis bacille Calmette-Guérin (BCG) aerosols in enclosed places. We constructed a facility (4.5 m x 3 m x 2.9 m) in which both ceiling- and wall-mounted UV fixtures (UV output: 10W and 5W respectively) were installed. The use of ceiling- and wall-mounted UV fixtures (total UV output: 15W) without mixing fan reduced the concentration of S. marcescens aerosols by 46% (range: 22-80%) at 2 air changes per hour (ACH) and 53% (range: 40-68%) at 6 ACH. The use of ceiling- and wall-mounted UV fixtures with mixing fan increased the UV effectiveness in inactivating S. marcescens aerosols to 62% (range: 50-78%) at 2 ACH and to 86% (81-89%) at 6 ACH. For BCG aerosols, UV effectiveness in inactivating BCG aerosols at 6 ACH were 52% (range: 11-69%) by ceiling-mounted UV fixture only (total UV output: 10W) and 64% (51-83%) by both ceiling- and wall-mounted UV fixtures (total UV output: 15W). Our results indicated that the equivalent ventilation rate attributable to upper-room UVGI for BCG aerosols ranged from 1 ACH to 22 ACH for ceiling-mounted UV fixtures and from 6.4 ACH to 28.5 ACH for ceiling- and wall-mounted UV fixtures. Both generalized linear and generalized additive models were fitted to all our data. The regression results indicated that the number of UV fixtures, use of mixing fan, and air exchange rate significantly affected UV effectiveness (p < 0.01, 0.01, 0.01 respectively). However, the strain difference (S. marcescens vs. BCG) appeared less important in UV effectiveness (p = 0.26). Our results also indicated that UV effectiveness increased at higher temperature ((italic)p(/italic) < 0.01), lower dry-bulb temperature ((italic)p(/italic) = 0.21), and colder air from a supply grill located near the ceiling (p = 0.22).

Entities:  

Mesh:

Substances:

Year:  2002        PMID: 11781170      PMCID: PMC1240698          DOI: 10.1289/ehp.0211095

Source DB:  PubMed          Journal:  Environ Health Perspect        ISSN: 0091-6765            Impact factor:   9.031


  21 in total

1.  Influence of relative humidity on particle size and UV sensitivity of Serratia marcescens and Mycobacterium bovis BCG aerosols.

Authors:  G Ko; M W First; H A Burge
Journal:  Tuber Lung Dis       Date:  2000

2.  Patterns of tuberculosis transmission in Central Los Angeles.

Authors:  P F Barnes; Z Yang; S Preston-Martin; J M Pogoda; B E Jones; M Otaya; K D Eisenach; L Knowles; S Harvey; M D Cave
Journal:  JAMA       Date:  1997-10-08       Impact factor: 56.272

3.  Combined effects of constant sublethal UVA irradiation and elevated temperature on the survival and general metabolism of the convict-cichlid fish, Cichlasoma nigrofasciatum.

Authors:  K Winckler; L Fidhiany
Journal:  Photochem Photobiol       Date:  1996-04       Impact factor: 3.421

4.  Effect of aerosolization on subsequent bacterial survival.

Authors:  M V Walter; B Marthi; V P Fieland; L M Ganio
Journal:  Appl Environ Microbiol       Date:  1990-11       Impact factor: 4.792

5.  Tuberculosis in New York City: focal transmission of an often fatal disease.

Authors:  E A Nardell; P W Brickner
Journal:  JAMA       Date:  1996-10-16       Impact factor: 56.272

6.  Structural adaptations of the cold-active citrate synthase from an Antarctic bacterium.

Authors:  R J Russell; U Gerike; M J Danson; D W Hough; G L Taylor
Journal:  Structure       Date:  1998-03-15       Impact factor: 5.006

7.  Estimation of tuberculosis risk and incidence under upper room ultraviolet germicidal irradiation in a waiting room in a hypothetical scenario.

Authors:  G Ko; H A Burge; E A Nardell; K M Thompson
Journal:  Risk Anal       Date:  2001-08       Impact factor: 4.000

8.  Ultraviolet susceptibility of BCG and virulent tubercle bacilli.

Authors:  R L Riley; M Knight; G Middlebrook
Journal:  Am Rev Respir Dis       Date:  1976-04

9.  Influence of temperature and relative humidity on the survival of Chlamydia pneumoniae in aerosols.

Authors:  H J Theunissen; N A Lemmens-den Toom; A Burggraaf; E Stolz; M F Michel
Journal:  Appl Environ Microbiol       Date:  1993-08       Impact factor: 4.792

10.  Global surveillance for antituberculosis-drug resistance, 1994-1997. World Health Organization-International Union against Tuberculosis and Lung Disease Working Group on Anti-Tuberculosis Drug Resistance Surveillance.

Authors:  A Pablos-Méndez; M C Raviglione; A Laszlo; N Binkin; H L Rieder; F Bustreo; D L Cohn; C S Lambregts-van Weezenbeek; S J Kim; P Chaulet; P Nunn
Journal:  N Engl J Med       Date:  1998-06-04       Impact factor: 91.245

View more
  22 in total

1.  Ultraviolet-C irradiation for prevention of central venous catheter-related infections: an in vitro study.

Authors:  Tianhong Dai; George P Tegos; Tyler G St Denis; Don Anderson; Ed Sinofsky; Michael R Hamblin
Journal:  Photochem Photobiol       Date:  2010-11-12       Impact factor: 3.421

2.  Safety of upper-room ultraviolet germicidal air disinfection for room occupants: results from the Tuberculosis Ultraviolet Shelter Study.

Authors:  Edward A Nardell; Scott J Bucher; Philip W Brickner; Charles Wang; Richard L Vincent; Kathleen Becan-McBride; Mark A James; Max Michael; James D Wright
Journal:  Public Health Rep       Date:  2008 Jan-Feb       Impact factor: 2.792

3.  UVC LED Irradiation Effectively Inactivates Aerosolized Viruses, Bacteria, and Fungi in a Chamber-Type Air Disinfection System.

Authors:  Do-Kyun Kim; Dong-Hyun Kang
Journal:  Appl Environ Microbiol       Date:  2018-08-17       Impact factor: 4.792

4.  Minimizing the exposure of airborne pathogens by upper-room ultraviolet germicidal irradiation: an experimental and numerical study.

Authors:  Y Yang; W Y Chan; C L Wu; R Y C Kong; A C K Lai
Journal:  J R Soc Interface       Date:  2012-07-18       Impact factor: 4.118

5.  The history of ultraviolet germicidal irradiation for air disinfection.

Authors:  Nicholas G Reed
Journal:  Public Health Rep       Date:  2010 Jan-Feb       Impact factor: 2.792

6.  Aerosol susceptibility of influenza virus to UV-C light.

Authors:  James J McDevitt; Stephen N Rudnick; Lewis J Radonovich
Journal:  Appl Environ Microbiol       Date:  2012-01-06       Impact factor: 4.792

7.  Upper-room ultraviolet light and negative air ionization to prevent tuberculosis transmission.

Authors:  A Roderick Escombe; David A J Moore; Robert H Gilman; Marcos Navincopa; Eduardo Ticona; Bailey Mitchell; Catherine Noakes; Carlos Martínez; Patricia Sheen; Rocio Ramirez; Willi Quino; Armando Gonzalez; Jon S Friedland; Carlton A Evans
Journal:  PLoS Med       Date:  2009-03-17       Impact factor: 11.069

8.  Institutional Tuberculosis Transmission. Controlled Trial of Upper Room Ultraviolet Air Disinfection: A Basis for New Dosing Guidelines.

Authors:  Matsie Mphaphlele; Ashwin S Dharmadhikari; Paul A Jensen; Stephen N Rudnick; Tobias H van Reenen; Marcello A Pagano; Wilhelm Leuschner; Tim A Sears; Sonya P Milonova; Martie van der Walt; Anton C Stoltz; Karin Weyer; Edward A Nardell
Journal:  Am J Respir Crit Care Med       Date:  2015-08-15       Impact factor: 21.405

9.  Ultraviolet germicidal irradiation and its effects on elemental distributions in mouse embryonic fibroblast cells in x-ray fluorescence microanalysis.

Authors:  Qiaoling Jin; Stefan Vogt; Barry Lai; Si Chen; Lydia Finney; Sophie-Charlotte Gleber; Jesse Ward; Junjing Deng; Rachel Mak; Nena Moonier; Chris Jacobsen
Journal:  PLoS One       Date:  2015-02-23       Impact factor: 3.240

10.  Methodology for modeling the microbial contamination of air filters.

Authors:  Yun Haeng Joe; Ki Young Yoon; Jungho Hwang
Journal:  PLoS One       Date:  2014-02-11       Impact factor: 3.240

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.