Abstract

This study was conducted to investigate the effectiveness of dose-saving protocols in dual-source computed tomography (CT) coronary angiography compared with invasive coronary angiography (ICA). On 50 patients who underwent coronary CT angiography was performed dual-source CT (DSCT) and compared with ICA procedures. Entrance skin dose (ESD), which was measured at the thyroid gland, and effective dose (E) were assessed for both imaging modalities. The mean ESD measured at the thyroid gland was the highest at 120 kVp, followed by the 100 kVp DSCT and the ICA protocols with 4.0±1.8, 2.7±1.0 and 1.1±1.2 mGy, respectively. The mean E was estimated to be 10.3±2.1, 6.2±2.3 and 5.3±3.4 mSv corresponding to the 120-kVp, 100-kVp DSCT and ICA protocols, respectively. The application of 100 kVp in DSCT coronary angiography is feasible only in patients with a low body mass index of <25 kg m(-2), which leads to a significant dose reduction with the radiation dose being equivalent to that of ICA.

Entities:  

Mesh:

Substances:

Year:  2012        PMID: 22807493     DOI: 10.1093/rpd/ncs127

Source DB:  PubMed          Journal:  Radiat Prot Dosimetry        ISSN: 0144-8420            Impact factor:   0.972


  5 in total

1.  Experimental estimates of peak skin dose and its relationship to the CT dose index using the CTDI head phantom.

Authors:  Hugo de las Heras; Ronaldo Minniti; Sean Wilson; Chad Mitchell; Marlene Skopec; Claudia C Brunner; Kish Chakrabarti
Journal:  Radiat Prot Dosimetry       Date:  2013-07-16       Impact factor: 0.972

2.  Quantitative assessment on coronary computed tomography angiography (CCTA) image quality: comparisons between genders and different tube voltage settings.

Authors:  Teo Chee Chian; Norziana Mat Nassir; Mohd Izuan Ibrahim; Ahmad Khairuddin Md Yusof; Akmal Sabarudin
Journal:  Quant Imaging Med Surg       Date:  2017-02

3.  Chest circumference as a predictive parameter of computed tomography coronary angiography radiation doses from dual-source computed tomography.

Authors:  M Erdem Sagsoz; Ummugulsum Bayraktutan; Hayri Ogul; Mecit Kantarci
Journal:  Eurasian J Med       Date:  2013-02

4.  Dual-source CT coronary angiographic evaluation of coronary artery fistulas.

Authors:  Min Liu; Qing Hou; Xiaojuan Guo; Shuangkun Wang; Zhanhong Ma
Journal:  Exp Ther Med       Date:  2014-03-04       Impact factor: 2.447

5.  Double-low protocol for hepatic dynamic CT scan: Effect of low tube voltage and low-dose iodine contrast agent on image quality.

Authors:  Xiuli Zhang; Shaodong Li; Wenlou Liu; Ning Huang; Jingjing Li; Li Cheng; Kai Xu
Journal:  Medicine (Baltimore)       Date:  2016-06       Impact factor: 1.889