Literature DB >> 22806215

Conversion of a capture ELISA to a Luminex xMAP assay using a multiplex antibody screening method.

Harold N Baker1, Robin Murphy, Erica Lopez, Carlos Garcia.   

Abstract

The enzyme-linked immunosorbent assay (ELISA) has long been the primary tool for detection of analytes of interest in biological samples for both life science research and clinical diagnostics. However, ELISA has limitations. It is typically performed in a 96-well microplate, and the wells are coated with capture antibody, requiring a relatively large amount of sample to capture an antigen of interest . The large surface area of the wells and the hydrophobic binding of capture antibody can also lead to non-specific binding and increased background. Additionally, most ELISAs rely upon enzyme-mediated amplification of signal in order to achieve reasonable sensitivity. Such amplification is not always linear and can thus skew results. In the past 15 years, a new technology has emerged that offers the benefits of the ELISA, but also enables higher throughput, increased flexibility, reduced sample volume, and lower cost, with a similar workflow (1, 2). Luminex xMAP Technology is a microsphere (bead) array platform enabling both monoplex and multiplex assays that can be applied to both protein and nucleic acid applications (3-5). The beads have the capture antibody covalently immobilized on a smaller surface area, requiring less capture antibody and smaller sample volumes, compared to ELISA, and non-specific binding is significantly reduced. Smaller sample volumes are important when working with limiting samples such as cerebrospinal fluid, synovial fluid, etc. (6). Multiplexing the assay further reduces sample volume requirements, enabling multiple results from a single sample. Recent improvements by Luminex include: the new MAGPIX system, a smaller, less expensive, easier-to-use analyzer; Low-Concentration Magnetic MagPlex Microspheres which eliminate the need for expensive filter plates and come in a working concentration better suited for assay development and low-throughput applications; and the xMAP Antibody Coupling (AbC) Kit, which includes a protocol, reagents, and consumables necessary for coupling beads to the capture antibody of interest. (See Materials section for a detailed list of kit contents.) In this experiment, we convert a pre-optimized ELISA assay for TNF-alpha cytokine to the xMAP platform and compare the performance of the two methods (7-11). TNF-alpha is a biomarker used in the measurement of inflammatory responses in patients with autoimmune disorders. We begin by coupling four candidate capture antibodies to four different microsphere sets or regions. When mixed together, these four sets allow for the simultaneous testing of all four candidates with four separate detection antibodies to determine the best antibody pair, saving reagents, sample and time. Two xMAP assays are then constructed with the two most optimal antibody pairs and their performance is compared to that of the original ELISA assay in regards to signal strength, dynamic range, and sensitivity.

Entities:  

Mesh:

Substances:

Year:  2012        PMID: 22806215      PMCID: PMC3471270          DOI: 10.3791/4084

Source DB:  PubMed          Journal:  J Vis Exp        ISSN: 1940-087X            Impact factor:   1.355


  11 in total

1.  Correlation of XMAP and ELISA cytokine profiles; development and validation for immunotoxicological studies in vitro.

Authors:  Eleonora Codorean; Cornelia Nichita; Lucian Albulescu; Elena Răducan; Ionela Daniela Popescu; Alina Constantina Lonită; Radu Albulescu
Journal:  Roum Arch Microbiol Immunol       Date:  2010 Jan-Mar

2.  Improved multiplex immunoassay performance in human plasma and synovial fluid following removal of interfering heterophilic antibodies.

Authors:  Wilco de Jager; Berent J Prakken; Johannes W J Bijlsma; Wietse Kuis; Ger T Rijkers
Journal:  J Immunol Methods       Date:  2005-05       Impact factor: 2.303

3.  Validation and comparison of luminex multiplex cytokine analysis kits with ELISA: determinations of a panel of nine cytokines in clinical sample culture supernatants.

Authors:  Nefertiti C dupont; Kehui Wang; Pathik D Wadhwa; Jennifer F Culhane; Edward L Nelson
Journal:  J Reprod Immunol       Date:  2005-08       Impact factor: 4.054

4.  Quantitative validation and comparison of multiplex cytokine kits.

Authors:  Joanna L Richens; Richard A Urbanowicz; Rebecca Metcalf; Jonathan Corne; Paul O'Shea; Lucy Fairclough
Journal:  J Biomol Screen       Date:  2010-02-22

5.  Advanced multiplexed analysis with the FlowMetrix system.

Authors:  R J Fulton; R L McDade; P L Smith; L J Kienker; J R Kettman
Journal:  Clin Chem       Date:  1997-09       Impact factor: 8.327

6.  Multiplex reverse transcription PCR Luminex assay for detection and quantitation of viral agents of gastroenteritis.

Authors:  Jie Liu; Gibson Kibiki; Venance Maro; Athanasia Maro; Happy Kumburu; Ndealilia Swai; Mami Taniuchi; Jean Gratz; Denise Toney; Gagandeep Kang; Eric Houpt
Journal:  J Clin Virol       Date:  2011-01-21       Impact factor: 3.168

7.  Characterization and development of a Luminex(®)-based assay for the detection of human IL-23.

Authors:  Giovanni Rizzi; Yan J Zhang; Robert Latek; Russell Weiner; Paul W Rhyne
Journal:  Bioanalysis       Date:  2010-09       Impact factor: 2.681

8.  Simultaneous quantitation of 15 cytokines using a multiplexed flow cytometric assay.

Authors:  R T Carson; D A Vignali
Journal:  J Immunol Methods       Date:  1999-07-30       Impact factor: 2.303

9.  Simultaneous detection of 15 human cytokines in a single sample of stimulated peripheral blood mononuclear cells.

Authors:  Wilco de Jager; Henk te Velthuis; Berent J Prakken; Wietse Kuis; Ger T Rijkers
Journal:  Clin Diagn Lab Immunol       Date:  2003-01

10.  A method to extract cytokines and matrix metalloproteinases from Schirmer strips and analyze using Luminex.

Authors:  Karl R VanDerMeid; Stephanie P Su; Kathleen L Krenzer; Keith W Ward; Jin-Zhong Zhang
Journal:  Mol Vis       Date:  2011-04-27       Impact factor: 2.367

View more
  24 in total

Review 1.  Assays for the identification and prioritization of drug candidates for spinal muscular atrophy.

Authors:  Jonathan J Cherry; Dione T Kobayashi; Maureen M Lynes; Nikolai N Naryshkin; Francesco Danilo Tiziano; Phillip G Zaworski; Lee L Rubin; Jill Jarecki
Journal:  Assay Drug Dev Technol       Date:  2014-08       Impact factor: 1.738

2.  Generation of Immature, Mature and Tolerogenic Dendritic Cells with Differing Metabolic Phenotypes.

Authors:  Wen Jing Sim; Frano Malinarich; Anna-Marie Fairhurst; John Edward Connolly
Journal:  J Vis Exp       Date:  2016-06-22       Impact factor: 1.355

3.  Injury-induced MRP8/MRP14 stimulates IP-10/CXCL10 in monocytes/macrophages.

Authors:  Juan Wang; Yoram Vodovotz; Liyan Fan; Yuehua Li; Zheng Liu; Rami Namas; Derek Barclay; Ruben Zamora; Timothy R Billiar; Mark A Wilson; Jie Fan; Yong Jiang
Journal:  FASEB J       Date:  2014-10-23       Impact factor: 5.191

4.  Collagen: quantification, biomechanics, and role of minor subtypes in cartilage.

Authors:  Benjamin J Bielajew; Jerry C Hu; Kyriacos A Athanasiou
Journal:  Nat Rev Mater       Date:  2020-07-20       Impact factor: 66.308

5.  Smaller CpG-Conjugated Gold Nanoconstructs Achieve Higher Targeting Specificity of Immune Activation.

Authors:  Jun Yue; Roger M Pallares; Lisa E Cole; Emma E Coughlin; Chad A Mirkin; Andrew Lee; Teri W Odom
Journal:  ACS Appl Mater Interfaces       Date:  2018-06-21       Impact factor: 9.229

6.  Development and evaluation of a bead-based Multiplexed Fluorescent ImmunoAssay (MFIA) for detection of antibodies to Salmonella enterica serogroup B and C1 in pigs.

Authors:  Sanne Schou Berger; Ulla Riber; Vibeke Frøkjær Jensen; Klara Tølbøll Lauritsen; Lars Ole Andresen
Journal:  BMC Vet Res       Date:  2022-07-05       Impact factor: 2.792

7.  Development and Evaluation of a New Triplex Immunoassay That Detects Group A Streptococcus Antibodies for the Diagnosis of Rheumatic Fever.

Authors:  Alana L Whitcombe; Paulina Hanson-Manful; Susan Jack; Arlo Upton; Polly Atatoa Carr; Deborah A Williamson; Michael G Baker; Thomas Proft; Nicole J Moreland
Journal:  J Clin Microbiol       Date:  2020-08-24       Impact factor: 5.948

8.  The Split Virus Influenza Vaccine rapidly activates immune cells through Fcγ receptors.

Authors:  William E O'Gorman; Huang Huang; Yu-Ling Wei; Kara L Davis; Michael D Leipold; Sean C Bendall; Brian A Kidd; Cornelia L Dekker; Holden T Maecker; Yueh-Hsiu Chien; Mark M Davis
Journal:  Vaccine       Date:  2014-09-06       Impact factor: 3.641

9.  Four-parameter paired response curve for serial dilution assays.

Authors:  Youyi Fong; Sallie R Permar; Georgia D Tomaras
Journal:  J Biopharm Stat       Date:  2021-06-07       Impact factor: 1.503

10.  Multiplex detection of plant pathogens using a microsphere immunoassay technology.

Authors:  Ratthaphol Charlermroj; Orawan Himananto; Channarong Seepiban; Mallika Kumpoosiri; Nuchnard Warin; Michalina Oplatowska; Oraprapai Gajanandana; Irene R Grant; Nitsara Karoonuthaisiri; Christopher T Elliott
Journal:  PLoS One       Date:  2013-04-26       Impact factor: 3.240

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.