Literature DB >> 9299971

Advanced multiplexed analysis with the FlowMetrix system.

R J Fulton1, R L McDade, P L Smith, L J Kienker, J R Kettman.   

Abstract

The FlowMetrix System is a multiplexed data acquisition and analysis platform for flow cytometric analysis of microsphere-based assays that performs simultaneous measurement of up to 64 different analytes. The system consists of 64 distinct sets of fluorescent microspheres and a standard benchtop flow cytometer interfaced with a personal computer containing a digital signal processing board and Windows95-based software. Individual sets of microspheres can be modified with reactive components such as antigens, antibodies, or oligonucleotides, and then mixed to form a multiplexed assay set. The digital signal-processing hardware and Windows95-based software provide complete control of the flow cytometer and perform real-time data processing, allowing multiple independent reactions to be analyzed simultaneously. The system has been used to perform qualitative and quantitative immunoassays for multiple serum proteins in both capture and competitive inhibition assay formats. The system has also been used to perform DNA sequence analysis by multiplexed competitive hybridization with 16 different sequence-specific oligonucleotide probes.

Entities:  

Mesh:

Substances:

Year:  1997        PMID: 9299971

Source DB:  PubMed          Journal:  Clin Chem        ISSN: 0009-9147            Impact factor:   8.327


  134 in total

1.  A microsphere-based assay for multiplexed single nucleotide polymorphism analysis using single base chain extension.

Authors:  J Chen; M A Iannone; M S Li; J D Taylor; P Rivers; A J Nelsen; K A Slentz-Kesler; A Roses; M P Weiner
Journal:  Genome Res       Date:  2000-04       Impact factor: 9.043

2.  Reproducible and inexpensive probe preparation for oligonucleotide arrays.

Authors:  Y Zhang; B D Price; S Tetradis; S Chakrabarti; G Maulik; G M Makrigiorgos
Journal:  Nucleic Acids Res       Date:  2001-07-01       Impact factor: 16.971

3.  BADGE, Beads Array for the Detection of Gene Expression, a high-throughput diagnostic bioassay.

Authors:  L Yang; D K Tran; X Wang
Journal:  Genome Res       Date:  2001-11       Impact factor: 9.043

4.  A bead-based method for multiplexed identification and quantitation of DNA sequences using flow cytometry.

Authors:  A Spiro; M Lowe; D Brown
Journal:  Appl Environ Microbiol       Date:  2000-10       Impact factor: 4.792

5.  Genotyping single nucleotide polymorphisms directly from genomic DNA by invasive cleavage reaction on microspheres.

Authors:  Kakuturu V N Rao; Priscilla Wilkins Stevens; Jeff G Hall; Victor Lyamichev; Bruce P Neri; David M Kelso
Journal:  Nucleic Acids Res       Date:  2003-06-01       Impact factor: 16.971

6.  DNA probes on beads arrayed in a capillary, 'Bead-array', exhibited high hybridization performance.

Authors:  Yoshinobu Kohara; Hideyuki Noda; Kazunori Okano; Hideki Kambara
Journal:  Nucleic Acids Res       Date:  2002-08-15       Impact factor: 16.971

7.  High-throughput detection of pathogenic yeasts of the genus trichosporon.

Authors:  Mara R Diaz; Jack W Fell
Journal:  J Clin Microbiol       Date:  2004-08       Impact factor: 5.948

8.  Decoding randomly ordered DNA arrays.

Authors:  Kevin L Gunderson; Semyon Kruglyak; Michael S Graige; Francisco Garcia; Bahram G Kermani; Chanfeng Zhao; Diping Che; Todd Dickinson; Eliza Wickham; Jim Bierle; Dennis Doucet; Monika Milewski; Robert Yang; Chris Siegmund; Juergen Haas; Lixin Zhou; Arnold Oliphant; Jian-Bing Fan; Steven Barnard; Mark S Chee
Journal:  Genome Res       Date:  2004-04-12       Impact factor: 9.043

9.  Heterophile antibody interference in a multiplexed fluorescent microsphere immunoassay for quantitation of cytokines in human serum.

Authors:  Thomas B Martins; Brian M Pasi; Christine M Litwin; Harry R Hill
Journal:  Clin Diagn Lab Immunol       Date:  2004-03

Review 10.  Characteristics, mechanisms of action, and epitope mapping of anti-factor VIII antibodies.

Authors:  Géraldine Lavigne-Lissalde; Chantal Rothschild; Claire Pouplard; Priscilla Lapalud; Yves Gruel; Jean-François Schved; Claude Granier
Journal:  Clin Rev Allergy Immunol       Date:  2009-10       Impact factor: 8.667

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.