INTRODUCTION: Success rates with emergent endotracheal intubation (ETI) improve with increasing provider experience. Few objective metrics exist to quantify differences in ETI technique between providers of various skill levels. We tested the feasibility of using motion capture videography to quantify variability in the motions of the left hand and the laryngoscope in providers with various experience. METHODS: Three providers with varying levels of experience [attending physician (experienced), emergency medicine resident (intermediate), and postdoctoral student with no previous ETI experience (novice)] each performed ETI 4 times on a mannequin. Vicon, a 16-camera system, tracked the 3-dimensional orientation and movement of markers on the providers, handle of the laryngoscope, and mannequin. Attempt duration, path length of the left hand, and the inclination of the plane of the laryngoscope handle (mean square angular deviation from vertical) were calculated for each laryngoscopy attempt. We compared interattempt and interprovider variability of each measure. RESULTS: All ETI attempts were successful. Mean (SD) duration of laryngoscopy attempts differed between experienced [5.50 (0.68) seconds], intermediate [6.32 (1.13) seconds], and novice [12.38 (1.06) seconds] providers (P = 0.021). Mean path length of the left hand did not differ between providers (P = 0.37). Variability of the plane of the laryngoscope differed between providers: 8.3 (experienced), 28.7 (intermediate), and 54.5 (novice) degrees squared. CONCLUSIONS: Motion analysis can detect interprovider differences in hand and laryngoscope movements during ETI, which may be related to provider experience. This technology has potential to objectively measure training and skill in ETI.
INTRODUCTION: Success rates with emergent endotracheal intubation (ETI) improve with increasing provider experience. Few objective metrics exist to quantify differences in ETI technique between providers of various skill levels. We tested the feasibility of using motion capture videography to quantify variability in the motions of the left hand and the laryngoscope in providers with various experience. METHODS: Three providers with varying levels of experience [attending physician (experienced), emergency medicine resident (intermediate), and postdoctoral student with no previous ETI experience (novice)] each performed ETI 4 times on a mannequin. Vicon, a 16-camera system, tracked the 3-dimensional orientation and movement of markers on the providers, handle of the laryngoscope, and mannequin. Attempt duration, path length of the left hand, and the inclination of the plane of the laryngoscope handle (mean square angular deviation from vertical) were calculated for each laryngoscopy attempt. We compared interattempt and interprovider variability of each measure. RESULTS: All ETI attempts were successful. Mean (SD) duration of laryngoscopy attempts differed between experienced [5.50 (0.68) seconds], intermediate [6.32 (1.13) seconds], and novice [12.38 (1.06) seconds] providers (P = 0.021). Mean path length of the left hand did not differ between providers (P = 0.37). Variability of the plane of the laryngoscope differed between providers: 8.3 (experienced), 28.7 (intermediate), and 54.5 (novice) degrees squared. CONCLUSIONS: Motion analysis can detect interprovider differences in hand and laryngoscope movements during ETI, which may be related to provider experience. This technology has potential to objectively measure training and skill in ETI.
Authors: George M Saleh; Dan Lindfield; Dawn Sim; Elena Tsesmetzoglou; Vinod Gauba; David S Gartry; Salim Ghoussayni Journal: Arch Ophthalmol Date: 2009-06
Authors: Tariq Rahman; Swapna Chandran; David Kluger; Joseph Kersch; Laurens Holmes; Akira Nishisaki; Ellen S Deutsch Journal: Pediatr Emerg Care Date: 2011-08 Impact factor: 1.454
Authors: Jestin N Carlson; Jorge Quintero; Francis X Guyette; Clifton W Callaway; James J Menegazzi Journal: Prehosp Emerg Care Date: 2011-12-22 Impact factor: 3.077
Authors: Morten Bo Svendsen; Louise Preisler; Jens Georg Hillingsoe; Lars Bo Svendsen; Lars Konge Journal: World J Gastrointest Endosc Date: 2014-05-16
Authors: Jestin N Carlson; Samarjit Das; Stephanie Spring; Adam Frisch; Fernando De la Torre; Jessica Hodgins Journal: Biomed Res Int Date: 2015-06-16 Impact factor: 3.411
Authors: Marcia A Corvetto; Carlos Fuentes; Andrea Araneda; Pablo Achurra; Pablo Miranda; Paola Viviani; Fernando R Altermatt Journal: BMC Anesthesiol Date: 2017-09-29 Impact factor: 2.217